Overview: The YSI 3017M DPD Chlorine Analyzer is designed for continuous chlorine measurement in aquaculture and aquatic habitats. It helps prevent stress on aquatic life by monitoring chlorine levels accurately and reliably.
Key Features:
  • Accurate Measurement: Utilizes the DPD colorimetric method for measuring free or total chlorine, ensuring reliable data for process optimization.
  • Low Maintenance: Features Flow Injection Analysis, reducing maintenance time and reagent use.
  • Factory Calibrated: Comes pre-calibrated, eliminating the need for regular calibration.
  • Process Control: Includes two configurable relays for integration with PLCs to automate chemical dosing processes.
Specifications:
  • Measurement Method: N, N-Diethyl-p-phenylenediamine (DPD)
  • Measurement Range: 0-5 mg/L for free or total chlorine
  • Accuracy: ±0.03 mg/L or ±5%
  • Limit of Detection: 0.03 mg/L
  • Display: 2.8 x 6 cm backlit LCD
  • Enclosure: IP66 rated
  • Dimensions: 16.8 x 14.8 x 7.4 inches
  • Weight: <18 lbs (8 kg)
  • Warranty: 2 years
  • Compliance: Meets US EPA and ISO standards
Sample Requirements:
  • Flow Rate: 50 to 1,000 mL/min
  • Inlet Pressure: 1 to 20 psig
  • Temperature Range: 41 to 113 °F (5 to 45 °C)
Reagents:
  • Reagent Sets: Available for total and free chlorine measurement
  • Consumption: Approximately 30 days per bottle at a 2.5-minute interval
  • Storage Life: 5 years for buffer and indicator, 1 year for DPD powder
Power & Communication:
  • Power: 115-230 VAC, 50-60 Hz
  • Relays: Two relays rated at 6A, 30VDC
  • Outputs: One 4-20 mA analog output, RS-485 Modbus RTU digital output
Environmental Conditions:
  • Storage Temperature: 41 to 158 °F (5 to 70 °C)
  • Operating Temperature: 41 to 131 °F (5 to 55 °C)
  • Humidity: 90% at 40°C non-condensing
See more

Catalog excerpts

Chlorine 3017M DPD CHLORINE ANALYZER FOR AQUACULTURE & AQUATIC HABITATS-1

Chlorine 3017M DPD CHLORINE ANALYZER FOR AQUACULTURE & AQUATIC HABITATS Continuously measure chlorine in your aquatic application with YSI’s 3017M DPD chlorine analyzer. Prevent unnecessary stress on your aquatic life caused by excessive chlorine levels. With a low limit of detection, the 3017M is ideal for chlorine measurements in aquaculture and aquatic habitats. The analyzer features two configurable relays to alert you to harmful spikes in chlorine. Accurate and reliable – Measures free or total chlorine using the DPD colorimetric method. This highly accurate method of analysis provides reliable data for process optimization and control. Low maintenance – Flow Injection Analysis simplifies maintenance and saves you time. Simplified tubing and low reagent use reduce the frequency of instrument maintenance. For more information visit: Factory calibrated – Eliminates the need for regular calibration. Process Control – Two configurable relays that you can connect to a PLC to automate and control chemical

 Open the catalog to page 1
Chlorine 3017M DPD CHLORINE ANALYZER FOR AQUACULTURE & AQUATIC HABITATS-2

DPD CHLORINE ANALYZER SPECIFICATIONS Measurement Method Measurement Range 0-5 mg/L free or total chlorine, reagent dependent Measurement Interval Factory calibrated, 1-point if required General Display IP66 (with door latched) Instrument Dimensions 4 mounting struts bolted to back of unit Instrument Shipping Weight Regulatory Compliance US EPA regulations 40 CFR 141.74 and 40 CFR 136.3; Standard method 4500-CL-G; US EPA method 334.0; ISO method 7393-2 English, French, German, Italian, Spanish Sample Requirements Sample Flow Rate to Sample Inlet Device 50 to 1,000 mL/min when using Sample Inlet...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.