SIRIUS

SIRIUS

SIRIUS

Product catalog summary
Introduction
The document discusses the features and advantages of the Sirius Microincinerator, a modern laboratory device designed for sterilization purposes, particularly in microbiology laboratories.
Specifications
  • Sterilization Temperature: 850ºC – 1100ºC
  • Time to Reach Sterilization Temperature: 7-9 minutes
  • Sterilization Duration: 2-4 seconds
  • Surface Temperature During Operation: 30°C
  • Main Input Voltage: 210-230V, 50 Hz
  • Heater Operating Voltage: ~11.5V Max.
  • Energy Consumption: 0.150 kW/h
  • Quartz Glass Tube Dimensions: Ø 18 mm, length: 100 mm
  • Weight: 3100 grams
  • Dimensions: W150 x D250 x H215 mm
Features & Advantages
  • Supports working with gloves due to low exterior surface temperature.
  • Prevents aerosol formation, enhancing laboratory safety.
  • Energy-efficient with minimal power consumption.
  • Environmentally friendly design.
  • Suitable for slide fixation and sterilization of culture tubes.
  • Operational adjustment capability of 270º.
User Safety
  • Exterior surface temperature does not exceed 30ºC, ensuring safe handling.
  • Heater resistance operates at 12V for maximum user security.
  • Complies with new safety regulations, recommended by CDC and WHO as a safer alternative to traditional Bunsen burners.
Conclusion
The Sirius Microincinerator offers a safe, efficient, and environmentally friendly solution for laboratory sterilization needs, meeting modern safety standards and providing significant advantages over traditional methods.
See more

Catalog excerpts

SIRIUS-1

SIRIUS Microincinerator A Microincinerator you can touch! Meet new safety regulations with a revolutionary Microincinerator! .. WORK WITH GLOVES .. MULTIPLE USE .. USER SAFETY .. Sterilization After reaching a sterilization temperature of around 1000°C, loop and needle are sterilized in 2-4 seconds. .. Supports Working with Gloves With it’s unique design the temperature of the exterior surface does not exceed 30ºC.* .. Sterilization in quartz tube Prevents aerosol formation .. User Safety Heater resistance running with 12V Slide fixation Loop sterilization You can safely touch the exterior surface during operatio

 Open the catalog to page 1
SIRIUS-2

Laboratory and User Safety SIRIUS Microincinerator New safety regulations have meant that Microincinerators are increasingly replacing the traditional Bunsen burners that have long been fundamental to microbiology laboratories. Accordingly, CDC and WHO recommend using microincinerators in laboratories instead of Bunsen burners. Microorganisms taken from liquid cause formation of aerosol in Bunsen Burner applications. Since this process is carried out in quartz tube in the Sirius micro Incinerator aerosol formation is completely inhibited. When using biosafety cabinets contrary to bunsen burners,...

 Open the catalog to page 2