Clinical Case Overview

This document presents a clinical case involving the radiographic control of extra-short dental implants in a female patient aged 59. The treatment involved placement of extra-short implants of type OST®, specifically implants sized ø 5.25 x 6.5 mm at positions 36 and 37.

Implant Placement and Prosthetic Treatment

The patient received an "All on six" implant placement protocol, followed by a fixed aesthetic prosthesis on the implants. The case highlights the use of extra-short implants as a treatment option.

Radiographic Monitoring Timeline

  • Initial X-ray (27/11/2014): Baseline radiographic image before implant placement.
  • Post-surgical X-ray (15/01/2015): Imaging immediately after implant surgery to verify implant positioning.
  • 7-day control X-ray (22/01/2015): Early post-operative check to assess initial healing and implant stability.
  • 2-month control X-ray (12/03/2015): Mid-term evaluation of osseointegration progress.
  • 3-month X-ray with impression transfer (09/04/2015): Radiograph taken during prosthetic impression phase to confirm implant integration and positioning.
  • 4-month prosthesis control X-ray (07/05/2015): Assessment of prosthesis fit and implant condition after prosthetic loading.
  • 2-year control X-ray (16/03/2017): Long-term follow-up to evaluate implant success and bone stability over time.

Key Points and Recommendations

  • Extra-short implants (6.5 mm length) can be successfully used in fixed prosthetic rehabilitation, even in cases requiring "All on six" protocols.
  • Systematic radiographic monitoring at multiple time points is critical to assess implant integration, prosthetic fit, and long-term stability.
  • Use of 3D reconstruction and impression transfer radiographs aids in precise prosthetic planning and verification.
  • Long-term follow-up (2 years) demonstrates the viability and stability of extra-short implants in clinical practice.

This case supports the clinical efficacy of extra-short implants combined with fixed prostheses, emphasizing the importance of structured radiographic controls throughout treatment phases.

See more

Catalog excerpts

Caso clínico 8-1

Caso clfnico 8 Control Radiografico implantes extra-cortos/ X-ray controlof extra-short implants Colaboracion Dr. Juan Pedro Manzon Esteve. Cliniksalud Odontologos. Valencia Casos Clinicos

 Open the catalog to page 1
Caso clínico 8-2

r "a • Genero: Femenino • Edad: 59 anos • Tratamiento: Colocacion de Implantes extra cortos • Tipo y talla de implante: OST® • 36 y 37 0 5,25*6,5mm vJ • Gender: Female • Age: 59 years old • Treatment: extra-short implants • Type and Implan size: OST® • 36 y 37 0 5,25*6,5mm v) Casos CLinicos

 Open the catalog to page 2
Caso clínico 8-3

Prótesis fija estética sobre implantes Casos Clinico

 Open the catalog to page 3
Caso clínico 8-4

Prótesis fija estética sobre implantes RX INICIAL 27/11/2014 / INITIAL X-RAY 27/11/2014 RX POSTQUIRÚRGICA 15/01/2015 / POST SURGICAL X-RAY 15/01/2015 Casos Clini

 Open the catalog to page 4
Caso clínico 8-5

RX CONTROL A LOS 7 DIAS (22/01/2015) /X-RAY CONTROL 7 DAYS (22/01/2015) RX CONTROL A LOS 2 MESES (12/03/2015) / X-RAY CONTROL 2 MONTHS (12/03/2015) RX CON TRANSFER DE IMPRESION (3 MESES) (9/04/2015) / X-RAY WITH IMPRESSION TRANSFER (3 MONTHS) (9/04/2015) RX CONTROL PROTESIS (4 MESES) 7/05/2015 / PROSTHESIS CONTROL X-RAY (4 MONTH) 07/05/2015 RX CONTROL (2 ANOS) 16/03/2017 / X-RAY CONTROL (2 YEARS) 16/03/2017 Casos Clinicos