video corpo

ZINIC Internal hex connection implants
67Pages

{{requestButtons}}

Catalog excerpts

ZINIC Internal hex connection implants - 1

Internal hex connection implants

Open the catalog to page 1
ZINIC Internal hex connection implants - 3

Internal hex connection implants

Open the catalog to page 3
ZINIC Internal hex connection implants - 4

Published - January 2022 | ZIACOM® All rights reserved

Open the catalog to page 4
ZINIC Internal hex connection implants - 5

Important information Please read carefully before using ZIACOM® products General information The total or partial use, handling and/or application of ZIACOM® products at any stage of their implementation by personnel who are unqualified or lack the necessary This document contains basic information on the use of original ZIACOM® dental training will automatically void any type of warranty and may cause severe damage implant systems, hereafter referred to as ZIACOM® dental implants or simply ZIACOM® products. This document has been created as quick guide for clinicians responsible for...

Open the catalog to page 5
ZINIC Internal hex connection implants - 7

ZIACOM quality Zitium titanium Investment in innovation and training ZIACOM® around the world - Regional headquarters Zinic® Internal hex connection implants Zinic® implant Surface treatments - Titansure surface treatment Product presentation Zinic references Product sheet Abutments | Direct-to-implant restorations 25 Abutments | Restorations using transepithelials 35 Surgical instruments Prosthetic instruments Simplified surgical protocol Cleaning, disinfection and sterilisation

Open the catalog to page 7
ZINIC Internal hex connection implants - 8

The Company Together for health ZIACOM® has been working for more than 15 years to improve the oral health and well-being of patients around the world by designing and manufacturing innovative, high-quality dental implant, prosthetic component, surgical instrument and biomaterial solutions. The company was founded in 2004 with 100% Spanish capital and began its activity as a manufacturer of dental implants and abutments for several European companies before launching its own brand of implant systems in 2006. In 2015. ZIACOM® introduced its diversification strategy with the development of...

Open the catalog to page 8
ZINIC Internal hex connection implants - 9

Investment in innovation and training In order to always offer the very best solutions for the well-being of every patient, and thanks to the experience and dedication of our highly-qualified professionals and innovative Technological Centre, our R&D&I team works incessantly in the field of research and innovation to improve our products and develop new solutions to meet the demands and needs of both patients and dentists. We also invest in research and ongoing training as a way of providing scientific support to the sector and we firmly believe in training young professionals to ensure the...

Open the catalog to page 9
ZINIC Internal hex connection implants - 11

Internal hex connection implants

Open the catalog to page 11
ZINIC Internal hex connection implants - 12

implants Characteristics CONNECTION • Internal hex connection. • 1.5 mm deep prosthesis hex: improves distribution of longitudinal forces. • Conical bevel: reduces infiltration. • Conical friction: reduces micromovements. • Platform switching: soft tissue modelling and emergence profile shaping. Internal hex prosthetic connection NECK/COLLAR • Microthread design: preserves marginal bone. Double, reduced-angle thread makes insertion easier • Microthread extension: improves load distribution. • Macrodesign: optimal cortical compression. • 0.2-mm machined area on bevel. Active apex BODY •...

Open the catalog to page 12
ZINIC Internal hex connection implants - 13

When choosing the correct implant length, consider the overdrill due to the length of the drill tip: TOTAL IMPLANT DIMENSIONS

Open the catalog to page 13
ZINIC Internal hex connection implants - 14

implants Surface treatments Titansure® surface Implants inserted following surface treatment are known to benefit from improved osseointegration by increasing the bone-to-implant contact area. This is partly due to the implant’s chemical composition and topographical characteristics. With our Titansure® surface treatment, at Ziacom Medical we have obtained a contaminant-free surface topography and optimal average macroand microporosity values, which are key specifications for achieving prompt and proper osseointegration and, in turn, extremely reliable and predictable implants. TITANSURE®...

Open the catalog to page 14
ZINIC Internal hex connection implants - 15

Surface roughness analysis The roughness study was conducted with a Sensofar S NEOX interferometric-confocal microscope (Sensofar Medical, Terrasa, Spain) and SensoMAP Premium 7.4 software. The quantitative roughness profile parameters applied were: average roughness (Ra), root-mean-square roughness (Rq), maximum profile peak height roughness (Rp) and maximum profile valley depth roughness (Rv). Ra (μm) (SD) The 3D surface roughness (Sa), 3D root mean square height (Sq), maximum 3D peak height (Sp) and maximum 3D pit depth (Sv) were also recorded. Sa (μm) (SD) The roughness profile featured...

Open the catalog to page 15
ZINIC Internal hex connection implants - 16

implants Product presentation Blister packaging Available for implants with Titansure® surface treatment. Blister packs are heat sealed and include product labels in order to be able to trace products correctly and a flap for easy opening in the clinic but while preventing accidental opening. ZPlus® Mount Option ZIACOM® No-Mount option IMPORTANT Do not open the sterile container until just before inserting the implant. Outer identification label ZIACOM® implants are supplied in a sealed cardboard box that includes a product identification label with a description of their main...

Open the catalog to page 16
ZINIC Internal hex connection implants - 17

ZPlus® mount option Options for the Zinic® Shorty implant include the ZPlus® mount, a multi-functional abutment made from grade 5 ELI titanium (medical grade), which allows easy handling of the implant during surgical procedures. In addition, the ZPlus® mount concept is based on reducing treatment costs, as it works equally well as an implant mount, impression abutment or provisional abutment for cement- or screw-retained restorations. Uses of ZPlus® mount As an implant mount The ZPlus® mount is available for the Zinic®, Zinic® MT, ZM4®, ZM4® MT ZM1® and Zinic® Shorty ranges. As already...

Open the catalog to page 17
ZINIC Internal hex connection implants - 18

implants Zinic® references Zinic® with ZPlus® - Titansure® references IMPLANT Cover screw* ZNPT ZRPT ZWPT * Screw included with each implant. (1) Internal hex depth. (2) Distance between faces of the internal hex. (3) Diameter of working platform.

Open the catalog to page 18
ZINIC Internal hex connection implants - 19

Zinic® with ZIACOM® No Mount - Titansure® references IMPLANT Cover screw* ZNPT ZRPT ZWPT * Screw included with each implant. (1) Internal hex depth. (2) Distance between faces of the internal hex. (3) Diameter of working platform.

Open the catalog to page 19

All Ziacom Medical catalogs and technical brochures