General Information
This document serves as a quick guide for clinicians on the use of ZIACOM® dental implant systems, emphasizing adherence to the manufacturer's protocols and the necessity of professional training.
Liability, Safety, and Guarantee
Users are responsible for the handling of ZIACOM® products. Improper use or combining with non-original components voids warranties and may harm patient health. Availability of products may vary by country.
Company Overview
Founded in 2004, ZIACOM® focuses on quality and innovation in dental implants, using high-strength Zitium® titanium that meets international standards. The company is expanding its global presence.
Product Characteristics
ZIACOM® implants feature a conical design with an internal hex connection to improve force distribution and reduce micromovements, made from Zitium® titanium.
Surface Treatments
The Titansure® surface treatment enhances osseointegration through sandblasting and acid etching, creating a rough surface that promotes bone growth and implant stability.
Recommendations and Protocols
Detailed recommendations for surgical and prosthetic procedures are provided, including cleaning, disinfection, and sterilization guidelines.
Conclusion
ZIACOM® is committed to high-quality dental solutions and supports research and training to advance dentistry.
Study on Implant Surfaces
The study examines the impact of three dental implant surfaces on cell viability and bone behavior, focusing on Titansure® Active surface treatment with BBL technology.
Surface Roughness Analysis
BBL-treated surfaces showed improved hydration and ion interaction, enhancing osseointegration.
In Vivo and In Vitro Research
BBL-treated implants demonstrated higher bone-to-implant contact and improved cell adhesion, leading to faster osseointegration.
Surface Treatment
BBL technology enhances implant surface hydration and interaction with bone-forming cells.
Histomorphometric Analysis
BBL-treated implants showed significantly higher BIC percentages, indicating quicker and more effective osseointegration.
Product Presentation
ZIACOM® offers various packaging options to preserve implant properties and ensure traceability.
Recommendations
Emphasizes selecting appropriate implant sizes and maintaining minimum distances between implants.
Conclusion
BBL-treated implants enhance osseointegration and reduce postoperative inflammation.
Calibrated Drill Stops and Surgical Instruments
Details on calibrated drill stops, surgical taps, and instruments, including platform types, lengths, and references.
Simplified Surgical Protocol
Outlines drilling protocols for different bone types, emphasizing control of the drilling axis and use of cortical drills.
Implant Insertion
Guidelines for implant insertion, including torque and speed recommendations, and the use of ZIACOM® implants without a mount.
General Recommendations
Advice on handling cover screws and preparing for the second surgical phase.
Implant Osseointegration and Surgical Protocol
Critical steps for successful osseointegration, specifying maximum torque and speed to prevent deformation.
Implant Insertion Recommendations
Monitor resistance when using a ratchet and handle surgical drills properly.
Cover Screw and Healing Abutment
Instructions for handling cover screws and selecting healing abutments.
Instrument Usage and Maintenance
Use instruments as recommended and dispose of damaged ones according to regulations.
Cleaning, Disinfection, and Sterilisation Protocols
Procedures for cleaning, disinfecting, and sterilising instruments, emphasizing complete drying and following guidelines.
Storage and General Recommendations
Store products in original packaging in a clean, dry location, and sterilize unsterilised items before use.
Contact Information
Contact details for Ziacom Medical SL in Spain and Ziacom Medical USA LLC are provided.
See more

Catalog excerpts

ZINIC-MT Conical implants with internal hex connection-1

Conical implants with internal hex connection

 Open the catalog to page 1
ZINIC-MT Conical implants with internal hex connection-3

Conical implants with internal hex connection

 Open the catalog to page 3
ZINIC-MT Conical implants with internal hex connection-4

Published - January 2022 | ZIACOM® All rights reserved

 Open the catalog to page 4
ZINIC-MT Conical implants with internal hex connection-5

Important information Please read carefully before using ZIACOM® products General information The total or partial use, handling and/or application of ZIACOM® products at any stage of their implementation by personnel who are unqualified or lack the necessary This document contains basic information on the use of original ZIACOM® dental training will automatically void any type of warranty and may cause severe damage implant systems, hereafter referred to as ZIACOM® dental implants or simply ZIACOM® products. This document has been created as quick guide for clinicians responsible for treatment,...

 Open the catalog to page 5
ZINIC-MT Conical implants with internal hex connection-7

ZIACOM quality Zitium titanium Investment in innovation and training ZIACOM around the world - Regional headquarters Zinic MT Conical implants with internal hex connection Surface treatments - Titansure® surface treatment - Titansure Active surface treatment Product presentation Product sheet Abutments | Direct-to-implant restorations 24 Abutments | Restorations using transepithelials 34 Surgical instruments Prosthetic instruments Simplified surgical protocol Cleaning, disinfection and sterilisation

 Open the catalog to page 7
ZINIC-MT Conical implants with internal hex connection-8

The Company Together for health ZIACOM® has been working for more than 15 years to improve the oral health and well-being of patients around the world by designing and manufacturing innovative, high-quality dental implant, prosthetic component, surgical instrument and biomaterial solutions. The company was founded in 2004 with 100% Spanish capital and began its activity as a manufacturer of dental implants and attachments for several European companies before launching its own brand of implant systems in 2006. In 2015, ZIACOM® introduced its diversification strategy with the development of new...

 Open the catalog to page 8
ZINIC-MT Conical implants with internal hex connection-9

Investment in innovation and training In order to always offer the very best solutions for the well-being of every patient, and thanks to the experience and dedication of our highly-qualified professionals and innovative Technological Centre, our R&D&I team works incessantly in the field of research and innovation to improve our products and develop new solutions to meet the demands and needs of both patients and dentists. We also invest in research and ongoing training as a way of providing scientific support to the sector and we firmly believe in training young professionals to ensure the best...

 Open the catalog to page 9
ZINIC-MT Conical implants with internal hex connection-11

Conical implants with internal hex connection

 Open the catalog to page 11
ZINIC-MT Conical implants with internal hex connection-12

implants Characteristics CONNECTION • Internal hex connection. • 1.5 mm deep prosthesis hex: improves distribution of lengthinal forces. • Conical bevel: reduces infiltration. • Conical friction: reduces micromovements. • Platform switching: soft tissue modelling and emergence profile shaping. Internal hex prosthetic connection CORTICAL ZONE • 0.4 mm machined ring: allows the prosthetic gap to be raised with respect to the bone crest in average/thick biotypes; avoids exposing the treated surface of irregular crests. Double, reduced-angle thread makes insertion easier • Microthread design: preserves...

 Open the catalog to page 12
ZINIC-MT Conical implants with internal hex connection-13

New product. Check availability. When choosing the correct implant length, consider the overdrill due to the length of the drill tip: TOTAL IMPLANT DIMENSIONS

 Open the catalog to page 13
ZINIC-MT Conical implants with internal hex connection-14

implants Surface treatments Titansure® surface Implants inserted following surface treatment are known to benefit from improved osseointegration by increasing the bone-to-implant contact area. This is partly due to the implant’s chemical composition and topographical characteristics. With our Titansure® surface treatment, at Ziacom Medical we have obtained a contaminant-free surface topography and optimal average macroand microporosity values, which are key specifications for achieving prompt and proper osseointegration and, in turn, extremely reliable and predictable implants. TITANSURE® SURFACE...

 Open the catalog to page 14
ZINIC-MT Conical implants with internal hex connection-15

Surface roughness analysis The roughness study was conducted with a Sensofar S NEOX interferometric-confocal microscope (Sensofar Medical, Terrasa, Spain) and SensoMAP Premium 7.4 software. The quantitative roughness profile parameters applied were: average roughness (Ra), root-mean-square roughness (Rq), maximum profile peak height roughness (Rp) and maximum profile valley depth roughness (Rv). Ra (μm) (SD) The 3D surface roughness (Sa), 3D root mean square height (Sq), maximum 3D peak height (Sp) and maximum 3D pit depth (Sv) were also recorded. Sa (μm) (SD) The roughness profile featured peaks...

 Open the catalog to page 15
ZINIC-MT Conical implants with internal hex connection-16

implants Surface treatments Titansure® Active surface treatment ZIACOM® presents the Titansure® Active surface treatment with bone bioactive liquid (BBL) as the latest innovation for the presentation of our dental implants. The Titansure® Active surface treatment is a combination of Titansure® with BBL technology (Bone Bioactive Liquid), a patent acquired by ZIACOM® and developed by the Biointelligence Systems research group led by Professor Maher Al-Atari Abou-Asi. “BBL technology consists of a saline solution containing calcium chloride (CaCl2) and magnesium chloride (MgCl2.6H2O) with a net...

 Open the catalog to page 16
ZINIC-MT Conical implants with internal hex connection-17

Conclusions Within the scope of this study, the histomorphometric analysis demonstrated that the group B implants achieved quicker and more effective osseointegration than control group A. Nevertheless, an assessment of bone growth in the medullary portion of the subjects’ tibiae revealed the new surface’s potential for osteoinduction. As explained by Dr. Sérgio Alexandre Gehrke, the histologist in charge of the study: “Within the study’s limits, data from the histomorphometric analysis of the implants with a BBL-treated surface (78.92 + 0.3%) highlighted a much quicker and more effective osseointegration...

 Open the catalog to page 17
ZINIC-MT Conical implants with internal hex connection-18

implants Product presentation Packaging tailored to the type of surface ZIACOM® offers two different types of product packaging depending on the type of implant surface: Blister packaging Available for implants with Titansure® surface treatment. The blisters are heat-sealed and include identification labels for product traceability and a flap for easy opening in the clinic but while preventing accidental opening. Bottle packaging Available for implants with Titansure® Active surface treatment. The sealed bottle contains bone bioactive liquid (BBL) to ensure the perfect preservation of the implant’s...

 Open the catalog to page 18
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.