Product catalog summary
Introduction
The Longevity® Offset & Oblique Liners Surgical Technique is designed to address joint instability in Total Hip Arthroplasty. It focuses on issues such as component misalignment, soft tissue laxity, and impingement, utilizing specialized acetabular liners for the Continuum®, Trilogy® IT, and Allofit® IT Acetabular systems.
Oblique Liner
The Oblique Liner enhances acetabular version and joint lateralization by rotating the liner 10 degrees outward, providing variable joint anteversion and abduction while maintaining a comparable range of motion.
Offset Liner
The Offset Liner is designed to lateralize the center of rotation of the cup, aiding in joint stability.
Shell Insertion and Fixation
Instructions for implanting acetabular shells are provided, with screw fixation recommended to counteract higher forces at the shell-to-bone interface.
Liner Removal
Standard techniques are outlined for shell insertion and liner removal, ensuring no damage to the shell taper or locking mechanisms.
Inserting the Provisional and Final Liners
Provisional liners come in two styles, with or without a permanently affixed locking screw. Proper cleaning and orientation are crucial before inserting the final polyethylene liner, as the liner's position can affect leg length.
Trial Range of Motion
A trial reduction is performed to check for stability and range of motion, ensuring compatibility among components.
Verifying Liner Seating
Proper seating of the liners is verified by ensuring anti-rotation tabs are flush with the shell face.
Final Reduction
A final reduction assesses range of motion, hip stability, and limb length.
Product Specifications
The document lists various Longevity Offset Liners with specific item numbers and descriptions, detailing sizes and offsets available for different liner diameters.
Overview
The document provides a comprehensive list of Longevity and Provisional Liners, including Offset and Oblique types, categorized by their offset measurements and sizes, with specific item numbers and descriptions.
Sections
  • Longevity Offset Liners: Lists various Longevity Liners with a 7mm offset, available in sizes 32mm and 36mm, identified by unique item numbers and descriptions.
  • Provisional Liners: Detailed with 7mm offsets in sizes 28mm, 32mm, and 36mm, specifying core sets and jumbo sets with item numbers and descriptions.
  • Oblique Liners: Covers Longevity Oblique Liners available in 28mm, 32mm, and 36mm sizes, listed with corresponding item numbers and descriptions.
  • Instrument Base Trays: Includes a list of trays used for storing and organizing the liners, with specific notes on availability and usage.
Key Information
  • All liners have a 7mm offset, a critical specification for their application.
  • The document categorizes liners by size and type for easy reference.
  • Instrument trays are essential for the organization and storage of liners.
Provisional Liner Sleeves Overview
Provides detailed specifications and descriptions of various provisional liner sleeves used in surgical techniques, focusing on Longevity® Offset & Oblique Liners.
Specifications
Lists item numbers and descriptions for oblique provisional liners available in different sizes, designed for use with specific surgical systems.
Instrument Base Trays
Mentions several instrument base trays used to organize and store the provisional liner sleeves.
Longevity Offset Polyethylene Liner Thickness Chart
Provides a detailed chart of Longevity liners, specifying thickness at the pole and 45° angles, including item numbers and descriptions.
Longevity Oblique Polyethylene Liner Thickness Chart
Details the thickness of Longevity oblique liners at the pole and 45° angles, categorized by size with item numbers and descriptions.
Important Notes
The document is intended for physicians and not laypersons, does not constitute medical advice, and includes a disclaimer about the CE mark and its validity.
See more

Catalog excerpts

Longevity® Offset and Oblique Liners Surgical Technique-1

Longevity® Offset & Oblique Liners Surgical Technique Offset & Oblique Surgical Technique with Allofit Longevity® Offset and Oblique Liners Surgical Technique

 Open the catalog to page 1
Longevity® Offset and Oblique Liners Surgical Technique-2

Longevity® Offset & Oblique Liners Surgical Technique Introduction Complete Acetabular System Joint instability is an important issue in both primary and revision Total Hip Arthroplasty. Causes of instability reported in the literature include, but are not limited to, component misalignment, soft tissue laxity and impingement.1 Two acetabular liners designed to help address these issues are available for the Continuum®, Trilogy® IT and Allofit® IT* Acetabular systems. Oblique Liner The Longevity Highly Crosslinked Polyethylene Oblique Liner was designed to provide variable joint anteversion and...

 Open the catalog to page 2
Longevity® Offset and Oblique Liners Surgical Technique-3

Longevity® Offset & Oblique Liners Surgical Technique Shell Insertion For Instructions on implanting the Continuum, Trilogy IT and Allofit IT Acetabular Shells, please refer to the corresponding Acetabular Cup System Surgical Technique. Supplemental Screw Fixation In both primary and revision cases, screw fixation is highly recommended, as the use of any oblique or offset liner may lead to higher forces at the shell-to-bone interface. For instruction on placing screws into Continuum, Trilogy IT or Allofit IT acetabular shells, please see the corresponding Acetabular Cup System Surgical Technique....

 Open the catalog to page 3
Longevity® Offset and Oblique Liners Surgical Technique-4

Longevity® Offset & Oblique Liners Surgical Technique Liner Removal Follow standard surgical techniques for shell insertion if required. Special care should be taken not to lever against the Shell during Liner removal. • Upon removal of any Liner, inspect the taper and polyethylene locking mechanisms for damage. • Once the acetabular Shell taper has been deformed through assembly of a hard bearing insert, the Shell should not be used with another hard bearing insert. • Remove any membranes from the inside of Shell or screw holes. • Clean and inspect the Shell to ensure its integrity and stability....

 Open the catalog to page 4
Longevity® Offset and Oblique Liners Surgical Technique-5

Longevity® Offset & Oblique Liners Surgical Technique • Drive the screw into the pilot hole by hand until the Liner is lifted out of the Shell (Fig. 5). • Special care should be taken not to damage the Shell taper or locking mechanism during removal of the Liner. Longevity Oblique Liner Inserting the Provisional Oblique Liner • There are two styles of Provisional Liners. One with a Locking Screw that is independent of the Provisional Liner, and one with a Locking Screw permanently affixed within the Provisional Liner. The permanently affixed locking screw provisional liners are available in a...

 Open the catalog to page 5
Longevity® Offset and Oblique Liners Surgical Technique-6

Longevity® Offset & Oblique Liners Surgical Technique Trial Range of Motion • Insert a head/neck Provisional onto the implanted Stem or Rasp Cone Provisional and perform a trial reduction. • Check for stability and range of motion. • Remove the Provisional components. Note: Refer to Zimmer’s product compatibility website, www.productcompatibility.zimmer.com, to determine compatibility among all selected components. Inserting the Oblique Liner • Prior to inserting the Longevity Liner, ensure that the Shell interior is clean and dry. • Place the final polyethylene Liner into the implanted Shell...

 Open the catalog to page 6
Longevity® Offset and Oblique Liners Surgical Technique-7

Longevity® Offset & Oblique Liners Surgical Technique Verifying Oblique Liner Seating Verify that the Longevity Oblique Polyethylene Liner is properly seated by running a finger around the face of the Shell to ensure the anti-rotation tabs are flush relative to the Shell face (Fig. 9). Longevity Offset Liner Inserting the Provisional Offset Liner • There are two styles of Provisional Liners. One with a Locking Screw that is Independent of the Provisional Liner, and one with a Locking Screw Permanently Affixed within the Provisional Liner. The permanently affixed locking screw provisional liners...

 Open the catalog to page 7
Longevity® Offset and Oblique Liners Surgical Technique-8

Longevity® Offset & Oblique Liners Surgical Technique Trial Range of Motion • Insert a head/neck Provisional onto the implanted Stem or Rasp Cone Provisional and perform a trial reduction. • Check for stability and range of motion. • Remove the Provisional components. Note: Refer to Zimmer’s product compatibility website, www.productcompatibility.zimmer.com, to determine compatibility among all selected components. Inserting the Offset Liner • Prior to inserting the Longevity Liner, ensure that the Shell interior is clean and dry. • Place the final polyethylene Liner into the implanted Shell...

 Open the catalog to page 8
Longevity® Offset and Oblique Liners Surgical Technique-9

Longevity® Offset & Oblique Liners Surgical Technique Verifying Offset Liner Seating Smaller Sized Liners • Liner sizes 28 CC - 28 GG, 32 EE - 32 II and 36 HH - 36 KK include a lip that has window cut outs to allow for visualization of two anti-rotation tabs. Utilize the window cut outs to verify proper seating of the liner by ensuring that the anti-rotation tabs are flush relative to the Shell face (Fig. 12). Larger Sized Liners • Liner sizes 28 HH - 28 QU, 32 JJ - 32 VV, 36 LL - 36VV do not have a lip which allow for visualization of the anti-rotation tabs. Run a finger around the Shell face...

 Open the catalog to page 9
Longevity® Offset and Oblique Liners Surgical Technique-10

Longevity® Offset & Oblique Liners Surgical Technique Longevity Offset Liners Longevity Offset Liners 28mm Item Number Description Longevity Offset Liners 36mm Item Number Longevity Liner, 7mm Offset, 40 CC x 28 Longevity Liner, 7mm Offset, 50 HH x 36 Longevity Liner, 7mm Offset, 42 DD x 28 Longevity Liner, 7mm Offset, 52 II x 36 Longevity Liner, 7mm Offset, 44 EE x 28 Longevity Liner, 7mm Offset, 54 JJ x 36 Longevity Liner, 7mm Offset, 46 FF x 28 Longevity Liner, 7mm Offset, 56 KK x 36 Longevity Liner, 7mm Offset, 48 GG x 28 Longevity Liner, 7mm Offset, 58 LL x 36 Longevity Liner, 7mm Offset,...

 Open the catalog to page 10
Longevity® Offset and Oblique Liners Surgical Technique-11

Longevity® Offset & Oblique Liners Surgical Technique Offset Provisionals with Independent Locking Screws For use with Continuum, Trilogy IT and Allofit IT Systems 7mm Offset 28mm Prov. Liner Core Set KT-8794-005-28 Item Number Description 00-8734-008-28 00-8734-009-28 00-8734-010-28 Prov Liner, 7mm Offset, 48 GG x 28 Prov Liner, 7mm Offset, 50 HH x 28 Prov Liner, 7mm Offset, 52 II x 28 Prov Liner, 7mm Offset, 54 JJ x 28 Prov Liner, 7mm Offset, 56 KK x 28 Prov Liner, 7mm Offset, 58 LL x 28 Prov Liner, 7mm Offset, 60 MM x 28 Prov Liner, 7mm Offset, 62 NN x 28 Prov Liner, 7mm Offset, 64 OO x 28...

 Open the catalog to page 11