Zimmer® NexGen® LPS-Flex Mobile and LPS Mobile Bearing Knees
4Pages

{{requestButtons}}

Catalog excerpts

Zimmer® NexGen® LPS-Flex Mobile and LPS Mobile Bearing Knees - 1

Zimmer® NexGen® LPS-Flex Mobile and LPS-Mobile Bearing Knees Designed for rotation and safe high flexion

Open the catalog to page 1
Zimmer® NexGen® LPS-Flex Mobile and LPS Mobile Bearing Knees - 2

Exercise your options so your patients can exercise theirs Help restore natural knee kinematics and accommodate up to 155° of active flexion with the NexGen LPS-Flex Mobile and 120° of active flexion with LPS-Mobile Bearing Knee. An innovative more anterior axis of rotation for the tibial component is designed to accommodate femoral rollback during flexion. MINIMALLY INVASIVE SOLUTIONS™ Procedures Accommodating Safe Flexion to 155° of flexion MIS implants and procedures offer solid alternatives to traditional total knee arthroplasty through innovative, minimally invasive TKA techniques that...

Open the catalog to page 2
Zimmer® NexGen® LPS-Flex Mobile and LPS Mobile Bearing Knees - 3

A Distinctive Femoral Component A deepened patellar groove facilitates patellofemoral tracking throughout the full range of motion for greater patellar stability. Designed for deep flexion Smooth patellar tracking • The extended posterior flanges of the LPS-Flex femoral component safely accommodate tibiofemoral contact during deep flexion of 155°. • A deepened patellar groove relieves pressure on the patella, reducing forces that can cause premature wear. • At the surgeon’s discretion, the patella need not be resurfaced. Reducing wear The LPS-Flex and LPS femoral components feature...

Open the catalog to page 3
Zimmer® NexGen® LPS-Flex Mobile and LPS Mobile Bearing Knees - 4

ANTERIOR LOCATION OF TRUNNION Replicates the anatomical center of rotation. A central trunnion allows rotation only while resisting lift-off without direct AP translation. The Mobile Tibial Plate allows internal/external total axial rotation of 50°. Tibial Base Plate Anterior stop prevents spin-out. Reducing articular friction • Radiused edges reduce stresses that can lead to polyethylene wear. • Allowing only unidirectional, rotational motion potentially reduces cross-shear and consequent wear.3 USING YOUR CHOICE OF ZIMMER INSTRUMENTS • MIS NexGen Multi-Reference® 4-in-1 Instrumentation...

Open the catalog to page 4

All Zimmer Biomet catalogs and technical brochures

  1. A.L.P.S.®

    44 Pages

  2. Biologics

    24 Pages

  3. Sidus

    40 Pages

  4. ZImmer iASSIST

    44 Pages

  5. Persona Knee

    6 Pages

Archived catalogs