Overview: The Cryo 6 Cold Air Device is a skin cooling system designed for use during superficial laser skin procedures. It aims to minimize pain and thermal injury during laser and dermatological treatments, providing temporary topical anesthetic relief for injections. Unlike other cooling methods, it can cool the epidermis before, during, and after laser application without interfering with the laser beam.
Key Features:
  • Temperature Control: Provides cold air cooling down to -30°C.
  • User Interface: Features a large display and tactile glass keyboard with 6 preset programs for easy operation.
  • Program Storage: Offers storage for user-defined programs, including individual, favorite, and sequence programs.
  • Hand-Free Operation: An optional articulating arm and lightweight application hose facilitate ease of use.
  • Economic and Practical: No consumables required, full-day operation without downtime, and easy maintenance with a defrosting feature and accessible air filter.
Study and Results:
  • Objective: To investigate the influence of cold air cooling on therapeutic outcomes and side effects during pulsed dye laser treatment of facial telangiectasia.
  • Methodology: Conducted from September 2002 to February 2003 with 17 patients. Treatment areas were divided into no cooling, cooling to 20°C, and cooling to 17°C.
  • Results: Cooling to 20°C reduced purpura and pain significantly, with minimal effect on clearance. Cooling to 17°C further reduced purpura and pain but slightly affected clearance. Most patients preferred cooling to 20°C.
  • Conclusion: Cold air cooling significantly reduces side effects and increases patient satisfaction in laser therapy, with 20°C being an optimal balance.
Technical Data:
  • Power Supply: Available in 230 V / 50 Hz, 230 V / 60 Hz, and 115 V / 60 Hz versions.
  • Power Consumption: Maximum 1 KW, 260 W/h in standby.
  • Dimensions and Weight: H 645 mm / W 390 mm / L 680 mm, 60 kg.
  • Therapy Air-flow: 9 levels, max. 1000 l/min.
Contact Information: Zimmer MedizinSysteme GmbH, Junkersstraße 9, D-89231 Neu-Ulm, Tel. +49. 7 31. 97 61-291, Fax +49. 7 31. 97 61-299, [email protected], www.zimmer.de
See more

Catalog excerpts

Cryo 6 derma-2

The skin cooling system designed for superficial laser skin procedures. The Cryo 6 Cold Air Device is intended to minimize pain and thermal injury during laser and dermatological treatments and for temporary topical anesthetic relief for injections. Unlike other cooling methods, such as contact cooling, cryogen spray or ice packs, the Cryo 6 can cool the epidermis before, during and after the laser energy has been applied, without interfering with the laser beam.

 Open the catalog to page 2
Cryo 6 derma-3

Easy to operate A large display clearly indicates all treatment parameters. Cryo 6 features a tactile glass keyboard, which permits the selection of 6 preset programs. Select a program. Press Start. That‘s it! User Defined Programs An optional articulating arm facilitates hand free operation. 3 supplementary storage possibilities are available for user defined programs. The light weight application hose can be connected to selected laser hand-pieces. The user can easily regulate the air flow as needed. Storage possibility is available for the user’s favorite program. This program appears when...

 Open the catalog to page 3
Cryo 6 derma-4

Increased Patient Comfort Hand-free Operation No Consumables Easy Maintenance Room air is filtered and cooled down to -30°C by closed cooling circuit. - Cost efficient: no con sumable or additional costs - Powerful: full day oper ation with no downtime - Practical: a custom-de- signed glass shelf just where you need it – for a laser, smoke evacuator or accessories. A monitoring system measures the defrosted water level and a defrosting feature provides smoothrunning daily operation. The air filter is easy to access, just vacuum when dirty.

 Open the catalog to page 4
Cryo 6 derma-5

Lasers in Surgery and Medicine 9999:1–5 (2004) Evaluation of Different Temperatures in Cold Air Cooling With Pulsed-Dye Laser Stefan Hammes and Christian Raulin, MD* Laserklinik Karlsruhe, Karlsruhe, Germany Table 1 Treatment Results Mean Values Scales 0-3 (0 = no, 1 = Little, 2 = Medium, 3 = High) No cooling 20°C skin 17°C skin 2.41 Background and Objectives Cold air cooling is widely used in dermatological laser therapy. We investigated the influence of cold air cooling at different skin temperatures on therapeutic outcome and side effects of pulsed dye laser treatment of facial telangiectasia....

 Open the catalog to page 5
Cryo 6 derma-6

Technical Data Power Supply Versions Power Consumption in Stand-by Treatment Tube Length Housing Dimensions Therapy Air-flow Set up Menu Service Menu Options Light treatment tube D 33 Wheel with brake PL59GB | 11/2009 | Rights of Modification reserved | Concept and creation: burkert gestaltung, dornstadt/ulm | Photography: Rieger Fotodesign, Geislingen/Steige

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.