Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level
10Pages

{{requestButtons}}

Catalog excerpts

Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 1

Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level ZINSSER ANALYTIC by Gardner Denver

Open the catalog to page 1
Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 2

Designed for your processes Addressing everyday workflow challenges by creating suitable automation solutions is our passion. Zinsser Analytic developed an automated solution for synthesis, tailored to application-specific needs: Highly flexible robotic system Reliable results Fast and efficient parameter screening ^ Improved reproducibility Customised software interface ^ Fully automated product workup ^ Enhanced precision in dosage With our flexible liquid- and powder-handling system, all your synthesis challenges are addressed: ^ Liquid- and powder-handling ^ Filtration Product...

Open the catalog to page 2
Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 3

HARDWARE DESIGN 3-Channel tips and gripper for racks and pick up tools Wash station Control panel for DESYRE-Mix® gas supplies Racks with two 300 mL solvent bottles Racks with 36x 40 mL reagent vial Multiple DESYRE-Mix® with hotplates up to 150 °C Control panel for Evaporation manifold gas supplies

Open the catalog to page 3
Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 4

HARDWARE DESIGN Heavy-duty vortexer with isolated cooling box down to -20 °C Six-way-valve with precision syringe pumps of different volumes Pick up tools for gripper for different vial sizes Ultrasonic bath for cleaning of tip Evaporation manifold with parking station Vacuum filtration station for usage with filter blocks or SPE cartridges Ioniser for reduction of static charge

Open the catalog to page 4
Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 5

5-Digit balance for single vials Control panel for SPE manifolds Racks with glass vials Multiple cartridge racks Stacker for vial racks for storage Two 3-channel tips, one shower tip, one standard liquid handling tip and gripper for racks and pick up tools Cabinet for automation with removable window for shuttle module

Open the catalog to page 5
Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 6

We want to help you to unleash your full potential in high throughput synthesis. Accordingly we use a modular and parallel executable design of hardware. With our automation, every common and even complex synthesis steps, are achievable. As an example for a fully automated synthesis, including preparation and product workup, the synthesis of Phenyl(1-pyrrolidinyl)methanone-derivatives is shown. Starting materials are pyrrolidine-derivatives (A) and m-bromo-benzoic acid (B) and the product is built through two separate reaction steps. 1. Dispense reagents into vials 2. Prepare standard...

Open the catalog to page 6
Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 7

Liquid Handling • Multiple channel pipetting probes for precise pipetting of liquids and volatiles as well as “coax-gas" and flow controlled vacuum. • Precision in distribution syringes in connection to syringe pumps and manifold valves with various volumes. o Solid Handling • Solid transfer pipette for flowable powder (10 - 300 pL). • A rack for powder tips, discarding and cleaning stations. • Optional with a 4- or 5-digit balance for single vials. • From 24 to 96-well CRISSY®-Blocks are applicable with a 4-digit balance. o Filtration / Solid-Phase-Extraction • Filtration station for...

Open the catalog to page 7
Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 8

PRECISION IN EVERY DETAIL Racks and reaction blocks • ach rack is equipped with a carrier for defined E positioning on the platform ensuring the correct positions of the tips during pipetting. • lexible replacement of carriers with racks, is easily F possible when the used method changes. • eagents rack (4 x 300 mL or 24 x 20 mL or 40 mL) R with caps and septum. • Modular racks for your DESYRE-Mix®: – eaction blocks from 8 to 96 positions R (1 mL up to 40 mL each). – eflux blocks with 8 or 24 positions R (7 mL up to 20 mL). – All racks are available in aluminium or stainless steel. – epta...

Open the catalog to page 8
Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 9

SOFTWARE SOLUTION FOR YOUR SPECIFIC PROCESS Every process step is designed modularly. Therefore a variety of processes, using differing powders, chemicals and solvents, may be completed. The customized sequential arrangement of the process is composed with a specified MS Excel® file or our Worklist-Generator which is then executed with our WinLissy®-software. Worklist-Generator With the Worklist-Generator you can create individual processes with many adjustable parameters for sub steps. Drag and drop the needed methods to the desired positions of the worklist. Pipetting-Editor For pipetting...

Open the catalog to page 9
Automation of Synthesis Processes lifting your Research Output Frequency to the Next Level - 10

AMERICAS Zinsser NA, Inc. 19145 Parthenia Street Suite C Northridge, CA 91324 USA Tel: +1 818 341 2906 Fax: +1 818 341 2927 info@zinsserna.com HEADQUARTERS Gardner Denver Thomas GmbH Livry-Gargan-Str. 10 82256 Furstenfeldbruck Germany Tel: +49 8141 2280 0 Fax: +49 8141 8892136 thomas.de@gardnerdenver.com Gardner DenverGENERAL CONTACT EMEA Zinsser Analytic GmbH Schwalbacher Str. 62 65760 Eschborn Germany Tel: +49 6196 58693 0 Fax: +49 6196 58693 80 info.zinsser-analytic@gardnerdenver.com Please check out all our brands for your mission-critical flow control technologies: THOMAS by Gardner...