PCMCIA Card Slots M Series CCT Specifications Defibrillator Waveform: ZOLL Rectilinear Biphasic. Energy Selection: Selectable at 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 75, 100, 120, 150, 200 joules. (Delivered into 50 ohm load.) Charge Time: Less than 6 seconds with a new fully charged battery (first 15 charges to 200J.) Depleted batteries will result in a longer defibrillator charge time. Energy Display: Monitor display indicates both selected and delivered energy. Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message displayed on monitor. Marker on display and recorder paper identifies R-wave discharge point. Advisory Function: Single analysis or programmable auto re-analyze x3 with programmable auto energy level selection, screen prompts, and voice prompts. Charge Controls: Control on apex paddle and on device front panel. Paddles: External anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles. Multi-Function Electrode (MFE) Pads: Specifically designed adult anterior/posterior pre-gelled ZOLL MFE Pads, and Multi-Function stat•padz™ packaged in pairs. Built-In Defibrillator Tester: Tests defibrillator energy output and continuity of universal cable and paddles; documented on PCMCIA card and strip chart. Defibrillation Advisory: Evaluates electrode connection and patient ECG to determine if defibrillation is required. Shockable Rhythms: Ventricular fibrillation with amplitude > 100 µV and wide complex ventricular tachycardia with rates greater than 150 bpm. Multi-Function Electrode Impedance Measurement Range: 0-250 ohms. Invasive and Non-invasive Vital Signs Assessment Screen Type: Color LCD. Screen Size: 6.5 inches (16.5 cm) diagonally. Sweep Speed: 25 mm/sec. Viewing Time: 4 seconds. Traces: 3. Information: Heart Rate, Lead/Pads, Alarm On/Off, Advisory Functions and Prompts, Defibrillator Test Function, Error Corrections and Faults, Code Markers, Alarm Selection and Limits, Delivered Energy, SpO2, Pacer Functions, EtCO2, NIBP Invasive Pressures (2), , Temperature (2). ECG Monitoring Patient Connection: 3-lead ECG cable, 5-lead ECG cable, 12 lead cable, paddles or MFE Pads. Input selection on front panel. Input Protection: Fully defibrillator protected. Special circuit prevents distortion of ECG by pacer pulse. (Pacer version only.) Implanted Pacemaker Spike Display: Dedicated circuitry detects most implanted pacemaker spikes and provides standard display marker of spike on ECG trace. Bandwidth: 0.5-40 Hz (-3 dB) standard/0.05-150 Hz diagnostic. Lead Selection: Displayed on monitor. ECG Size: 0.5, 1, 1.5, 2, 3 cm/mV - display on monitor. Heart Rate: Digital display 0-300 bpm ±5%. Heart Rate Alarm: On/Off displayed on monitor. User-selectable, tachycardia 60-280 bpm, bradycardia 20-100 bpm. 1 Volt ECG Out: 1.0 volt/cm of deflection on strip chart recorder. < 25 ms delay from patient ECG input. Display Format: Non-fade moving bar display. SmartAlarms™: Beeper/voice prompts indicate shockable rhythm. NIBP (Option) Accepts two standard series Type II Flash Cards, 1-16 MB: Fax modem card capability in slot 2. PCMCIA Card Continuous recording of ECG, vital sign and device data; episodic recording of NIBP data. Playback on PC equipped with ZOLL Data Control and specified PCMCIA Card reader. Battery Packs Type: Rechargeable, sealed lead acid. Recharge Time: 7.2 hours or less with integral charger. Operating Time: For a new, fully charged battery pack at 20˚C: 60 defibrillator discharges at maximum energy (200 joules); 2.5 hours continuous ECG and SpO2 monitoring; 2.3 hours of continuous ECG with pacing (60 mA at 80 bpm) and SpO2 monitoring, or 1.5 hours of continuous ECG with pacing (60 mA at 80 bpm) SpO2 monitoring, EtCO2, and IBP monitoring. Pulse Oximetry Saturation (% SpO2) Range: 1%-100%. Pulse Rate (bpm) Range: 25-240. Saturation (% SpO2) Accuracy During No Motion Conditions: Adults - 70%-100% ± 2 digits, 0%-69% unspecified. Saturation (% SpO2) Accuracy During Motion Conditions: Adults - 70%-100% ± 3 digits, 0%-69% unspecified. Pulse (bpm) Accuracy During No Motion Conditions: 25 to 240 ± 3 digits. Pulse (bpm) Accuracy During Motion Conditions: 25 to 240 ± 5 digits. Saturation (% SpO2) Resolution: 1%. Pulse Rate (bpm) Resolution: 1 BPM. Bio-Compatibility: Patient contacting material meets requirements of ISO 10993-1, Biological Evaluation of Medical Device — Part 1, for external devices, intact surfaces and short-term exposure. Note: The M Series Pulse Oximetry Option is calibrated for functional saturation. Pacemaker (Option) Type: VVI demand; asynchronous (fixed rate) when used without ECG leads or in ASYNC pacing mode. Pulse: Rectilinear, constant current; 40 milliseconds ±2ms; amplitude variable 0 to 140 mA ±5% or 5 mA, whichever is greater; digitally displayed on the monitor (increments or decrements by a value of 2 mA); rate variable from 30 to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm). Output Protection: Fully defibrillator protected and isolated. Multi-Function Electrode (MFE) Pads: Specifically designed pre-gelled ZOLL stat•padzTM, pro-padzTM and pedi-padzTM MFE packaged in pairs. EtCO2 (Option) Sensor Type: Infrared, Mainstream. Warm-Up Time: Operational in 15 seconds, full specification within 60 seconds. Step Response Time: Less than 60 ms adult, less than 50 ms neonate. End Tidal CO2 (EtCO2) Range: 0-100 mmHg. End Tidal CO2 (EtCO2) Accuracy: 0-40 mmHg ±2 mmHg, 41-70 mmHg ±-5%, 71-100 mmHg ±8%. End Tidal CO2 (EtCO2) Resolution: 1 mmHg. Respiration Rate (RR) Range: 0-150 respirations per minute. Respiration Rate (RR) Resolution: 1 respiration/min. EtCO2 Alarm Limits: User-selectable/High 5 to 100 mmHg, Low 0 to 95 mmHg/OFF. Respiration Rate (RR) Alarm Limits: User-selectable, High 5 to 150 respirations per minute, Low 0 to100 respirations per minute/OFF. O2/N2O Compensation: User-configurable. Halogenated Agents: Specification allows for halogenated anesthetic agents, which may be present at normal clinical levels. The presence of desflurane in the exhaled breath beyond normal values (5-6%) may positively bias Carbon Dioxide values by up to an additional 2-3 mmHg. Barometric Pressure Compensation Range: 550-780 mmHg (automatic). Airway Adapter Deadspace: Adult <5 cc, Neonatal <.5 cc. Environmental: Recorder Paper: 90 mm (width). Speed: 25 mm/sec., 6-second delay. Annotations: Time, date, defib energy, heart rate, pacer output (pacer version only), QRS sync marker, ECG size, lead, alarm, defib test OK/Fail, analyze ECG, analysis halted, noisy ECG, shock advised, no shock advised, ECG too large, ECG too small, and diagnostic bandwidth. Printing Method: High-resolution, thermal array print head. Printout Modes: Manual or automatic - user-configurable. On/Off Control: Front panel and paddle. Automatic Function: 15-second recording initiated by alarm activation or defibrillator discharge. Operating Temperature: 10˚ to 40˚C. Storage and Shipping Temperature: -10˚to 55˚C. Electromagnetic Immunity: (EtCO2 Option): AAMI DF-2: IEC 1000-4-3, 15 V/m. Patient Population: Adult, Pediatric. Method: Oscillometric. Control: Automatic and manual measurements. Auto Intervals: 2.5, 3-10, 15, 20, 30, 45, 60, 90, 120 min. STAT Mode: Maximum number of measurements in 5 minutes, not to exceed 10. Displayed Pressures: Systolic, Diastolic, Mean. Displayed Units: mmHg, kPa. Systolic Range: 40 to 260 mmHg. Diastolic Range: 25 to 200 mmHg. Mean Range: 30 to 220 mmHg. Pressure Transducer Accuracy: ±3 mmHg. Redundant Circuit Overpressure Limit: 300 mmHg. Pulse Rate Range: 40 to 200 bpm. Typical Measurement Time: 30 seconds. 12-lead ECG and MUSE Interface (Option) 12 Simultaneously Acquired ECG Leads 12-lead ECG Bandwidth: 0.05 to 150 Hz. Optional Bandwidth: 0.05 to 40 Hz. Sampling Rate: 500 sps. A/D Resolution: 18-bits. ECG Printing Formats Supported: 4x3 (3 rows, 4 columns, 2.5-10 seconds), 4x3 Cabrera, 4x3 Median Complexes, 2x6 fax only (6 rows, 2 columns, 5 seconds). Two configurable Custom Lead Groups for 3 Lead strip chart reports. GE Medical Systems 12SL Analysis Algorithm:Interpretive Statements (configurable - ON/OFF), Global ECG Measurements, 12-Lead Measurements Matrix (configurable-ON/OFF). Fax Transmission: Group 3 Facsimile, 24 Preprogrammed Phone Numbers (each with 20 digits), Manual Dial Option, Pulse/Tone Option, Cellular phone-compatible modem, 11-Digit Alphanumeric Site and Device Identifier. Patient Demographics: Patient Name, Patient ID (automatically generated or manually entered), Age, Gender. IBP (Option) Number of Channels: 2 Transducer Requirements: Excitation Voltage: 2.5 V dc. Transducer Output: 5µV/V/mmHg. Input Impedance: minimum 250 ohms. Output Impedance: maximum 3000 ohms. Pressure Range: -50 to 300 mmHg. Offset Range: ±200 mmHg. Accuracy: ±2% measurement or, ±2 mmHg, whichever is greater, not including transducer. IBP Safety: per EN60601-2-34. ZOLL Medical Corporation 32 Second Avenue Burlington, Massachusetts 01803-4420 U.S.A. 800-348-9011 781-229-0020 781-272-5578 Telefax www.zoll.com ZOLL Medical European Operations Dodewaard, the Netherlands +31 488 4111 83 +31 488 4111 87 Telefax zolleur@worldonline.nl ZOLL Medical U.K. Ltd. Cheshire, England +44 1925 846 400 +44 1925 846 401 Telefax ZOLL Medical Deutschland GmbH Köln, Germany +49 221 398 9340 +49 221 398 9336 Telefax ZOLL Medical the Netherlands Dodewaard, the Netherlands +31 488 4111 83 +31 488 4111 87 Telefax zolleur@worldonline.nl ZOLL Medical Canada Mississauga, Ontario, Canada 905-629-5005 905-629-0575 Telefax ZOLL Medical France Paris, France +33 1 43 59 2020 +33 1 43 63 5138 Telefax info@zolleur.com ZOLL Medical Australia Pty. Ltd New South Wales, Australia +61 2-94208733 +61 2-94209834 Telefax ZOLL Medical Far East Regional Office New South Wales, Australia +612 43 292226 +612 43 292226 Telefax ZOLL Medical Middle East and Africa Region Office Dubai, United Arab Emirates +971 5 065 31504 +971 4 332 8835 Telefax ZOLL Medical Japan Tokyo, Japan +81 3 5768 0788 +81 3 5768 0788 Telefax ZOLL Medical Latin America Parkland, FL 33067 954-345-4224 954-345-2648 Telefax Temperature (Option) Number of Channels: 2. Probe Requirement: YS1 400 compatible. Temperature Measurement Range: 15 to 45˚C. Resolution: 0.1˚C, not including sensor. General Size: 10.2 in (25.9 cm) high x 10.3 in (26.2 cm) wide x 8.7 in (22.1 cm) deep. Weight: 17.2 lb. (7.82 kg) with Multi-Function Cable and battery; 19.2 lb. (8.4 kg) with paddles and battery. Design Standards: Meets or exceeds UL 2601, AAMI DF-39, AAMI DF-2, and IEC 601-2-4. Patient Safety: All patient connections are electrically isolated. Environmental: Operating Temperature: 0° to 50°C; Storage and Shipping Temperature: -20° to 60°C; Humidity: 5 to 95% relative humidity, non-condensing; Vibration: Mil Std 810E, Minimum Integrity Test; Shock: IEC 68-2-27, 50g 6mS half sine; Operating Pressure: 594 to 1060 mBar; Material Ingress: IEC 529, IP23; Electromagnetic Compatibility (EMC): CISPR; 11 Class B Radiated and Conducted Emissions; Electromagnetic Immunity: AAMI DF-2: IEC 801-3 to 20 V/m; Electrostatic Discharge: AAMI DF-2: IEC 1000-4-2; Conducted Susceptibility: IEC 1000-4-4, 1000-4-5, 1000-4-6. Options: Xtreme Pack™ I Carry Case Xtreme Pack™ II Durable Rubber Case for added protection. Specifications subject to change without notice. Rectilinear Biphasic, RescueNet and Xtreme Pack are trademarks of ZOLL Medical Corporation © ZOLL Medical Corporation 2002. All rights reserved. 9656-0155 Printed in USA 20M 4/02 CCT The Only Defibrillator You Will Want for Critical Care Transport Clinically Superior Resuscitation Therapy

Open the catalog to page 1

All ZOLL Medical Corporation catalogs and technical brochures

  1. ResQGARD

    6 Pages

  2. EMV+

    2 Pages

  3. ZOLL AED 3

    5 Pages

  4. Propaq® M

    2 Pages

  5. Eagle II MRI

    2 Pages

  6. Eagle II™

    2 Pages

  7. pedi-padz

    2 Pages

  8. pedi-padz II

    2 Pages

  9. Pediatric

    4 Pages

  10. TGXP - STx

    2 Pages

  11. CoolRepeat

    2 Pages

  12. STx

    2 Pages

  13. ResQPOD

    8 Pages

  14. AED Pro®

    5 Pages

  15. X Series®

    8 Pages

  16. ZOLL Online

    2 Pages

  17. 12-lead ECG

    2 Pages

  18. Propaq MD

    2 Pages

  19. Catheters

    2 Pages

  20. Propaq LT

    2 Pages

  21. CodeNet®

    4 Pages

Archived catalogs