Quick lock lid Lid interlock Light lid -up -down

Abrir o catálogo na página 1
CL series - 2

★Quick Lock Lid By the central lock lever, you can easily lock the lid with fingertip. The lid is lightened up and down by the automatic hinge. Even if you lose hold of the lid, it keeps stopped at the same position. ★Lid Interlock The lid is locked reliably during operation and till cooling down to the safe temperature (801C- ■ - adjustable by parameter). ★Electro Mechanical Lock This function brings more safety to operator by locking the lid at the power failure or in the power OFF, to prevent operator from contamination by contacting un-sterilized objects carelessly. Locking is released...

Abrir o catálogo na página 2
CL series - 3

© Pressure gauge © Temperature display ® Time display ® Start key Option ® Object temp, key OPERATION PATTERNS It can be chosen from 3 patterns (-DP:5 patterns) according to your purposes. Once changed the values are stored, even if the power is switched off. Dissoving of Culture medium© C : Heating / Warming TEMP. STER. WARM A Caution If a lot of materials difficult of air-exhaust, such as many small containers in sterilization bags, are sterilized at usable maximum temperature, pressure inside the chamber must increase and the over pressure detector may operate. Then, it is requested to...

Abrir o catálogo na página 3
CL series - 4

LOADING CAPACITY FOR LABORATORY FLASKS Round flasks Dimension

Abrir o catálogo na página 4
CL series - 5

| Object Temperature Sensor (For reliable sterilization) Object temperature will come up more slowly than temperature in the chamber,so sterilization time be added delay time to set time. It aids reliable sterilization that the timer begins to move only after the temperature measured by the object temperature reaches the set temperature. Necessaries for objects which prevent penetration of steam. It will be able to add on later. Chamber temperature- Object temperature--- Normal operation DELAY TIME | Automatic Water Supply (To save your manual water supply) In stead of troublesome check and...

Abrir o catálogo na página 5
CL series - 6

Autoclave for Laboratory use vL/vL'Ur series Model •Please specify the voltage when you order. •Specifications subject to change without notice for improvement. ALP Co.,Ltd. 3-3-10, Midorigaoka, Hamura-shi Tokyo 205-0003, Japan TEL.81 -42-579-0531 FAX.81 -42-579-0533 E-mail: alpco@wonder.ocn.ne.jp URL: http://www.alpco.co.jp

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos ALP Co.

  1. TR series

    2 Páginas

  2. MC series

    6 Páginas

  3. MC-3032 series

    6 Páginas

  4. KT-40 series

    4 Páginas

  5. KT series

    6 Páginas

  6. KY series

    2 Páginas

  7. KMD series

    2 Páginas

  8. RT/ST series

    4 Páginas

  9. RY/SY series

    4 Páginas

  10. GT series

    2 Páginas

  11. DCL/DCH series

    2 Páginas

  12. SB series

    1 Páginas

  13. A series

    1 Páginas

  14. CLG series

    6 Páginas

  15. CLM Series

    4 Páginas