Suction performance Vacuum adjustment three-step control Low: -25 kPa Medium: -55 kPa High: -75 kPa infinitely adjustable three-step control Low: -25 kPa Medium: -55 kPa High: -75 kPa infinitely adjustable Vacuum gauge Sliding cover Condensate trap Sound damping Secretion canister
Abrir o catálogo na página 3
Mains-operated respiratory tract ATMOS® C 261 Aspirator / DDS Portable secretion suction device, airflow rate of pump: 26 ± 2 l/min. Characteristics: Infinitely variable vacuum adjustment and precision indication, condensate trap, grad. ATMOS - secretion canister 1 l, lid for secretion canister with triple oversuction safety by modern filter technology, integrated DirectDocking-System. Included in delivery: Silicone suction hose Ø 6 mm, L = 1.3 m, fingertip, mains cable, 3 bacterial filters, hose connector, DDS canister, DDS canister lid, holding clamp, operating instructions ATMOS® C 261...
Abrir o catálogo na página 4
suction devices, 26 ± 2 l/min
Abrir o catálogo na página 5
Mains-operated respiratory tract ATMOS® C 161 Aspirator / DDS Portable secretion suction device, airflow rate of pump: 16 ± 2 l/min Characteristics: Infinitely variable vacuum adjustment and precision indication, condensate trap, grad. ATMOS - secretion canister 1 l, canister lid with triple oversuction safety by modern filter technology, integrated overflow protection and Direct-Docking-System. Included in delivery: Silicone suction hose Ø 6 mm, L = 1.3 m, fingertip, mains cable, 3 bacterial filters, hose connecter, DDS canister, DDS canister lid, holding clamp, operating instructions...
Abrir o catálogo na página 6
suction devices, 16 ± 2 l/min
Abrir o catálogo na página 7
ATMOS Batterys
Abrir o catálogo na página 8
Suction performance Vacuum adjustment three-step control Low: -25 kPa Medium: -55 kPa High: -75 kPa infinitely adjustable Mains operation by mains connection (with power pack charger REF 312.0439.0) Battery operation Battery operation time Charging time (at complete discharge) Blue cover to protect the control elements Condensate trap Secretion canister Vacuum gauge Battery level indication Mains operation
Abrir o catálogo na página 9
Battery-operated respiratory tract ATMOS® C 161 Battery / DDS Battery operated secretion suction device, airflow rate: 22 ± 2 l/min. Characteristics: Infinitely variable vacuum adjustment and precision indication, condensate trap, 5-step LED battery level indicator, lithium-ionic battery, graduated ATMOS secretion canister 1 l, canister lid, with triple oversuction safety by modern filter technology, integrated overflow protection and Direct-Docking-System. Included in delivery: Silicone suction hose Ø 6 mm, L = 1.3 m, fingertip, mains cable, 3 bacterial filters, hose connecter, DDS...
Abrir o catálogo na página 10
suction devices, 22 ± 2 l/min
Abrir o catálogo na página 11
ATMOS Direct-Docking-System Modern filter technology Integrated overflow protection Modern Direct Docking System DDS provide triple safety and an easier processing. With the introduction of the Direct-Docking-System DDS in the lower price category ATMOS presents a new generation of portable respiratory tract suction systems. Up to now there was uncertainty when dealing with the hoses – now that has come to an end: With the innovative ATMOS DDS the hose connection between the suction system and the secretion jar is no longer required: no hose, no problem – just dock! This procedure...
Abrir o catálogo na página 12
Cleaning and care Bacterial filter The bacterial filter prevents bacteria and liquids from seeping into the device. Therefore, make sure the device is operated only with an original ATMOS bacterial filter! Exchange the bacterial filter at least once a week. Immediate change is necessary if it becomes wet or dirty or when the device is used for an other patient. General information Please excercise special care whilst handling the device! As it is essential to avoid transmission of germs and illness, the suction device may be solely used by one patient. Please observe the recommendations...
Abrir o catálogo na página 13
Reprocessing for further u In the past: Work steps: n Pre-cleaning Opening the device Condition appraisal Thorough cleaning and disinfection Exchange of all air and secretion ducting parts (including inner parts) Exchange of accessories and consumables Packing/shipment Reprocessing: long-winded and expensive Only to be performed by the ATMOS service or an authorised ATMOS partner Alone in Germany there are around 20,000 patients, who are not able to cough up secretion from the respiratory tract. Here a suction device should be available. For the use at home, health insurance companies...
Abrir o catálogo na página 14
use of suction devices Today: Work steps: n Pre-cleaning Condition appraisal without having to open the device Exchange of accessories and consumables Packing/shipment Quick appraisal of the hygienic condition Reprocessing: prompt and cost effective These devices have an integrated service indicator, the so-called condensate trap. This indicator enables a quick and cost-saving visual inspection regarding its condition without having to open it. In the case where no discolouring, residues or humidity are visible in the condensate trap, this proves, the device has always been operated...
Abrir o catálogo na página 15
Mediz inTech nik ... for Mediz a better life inTech nik ... for a bett Atem wegs absau gung Application: Oral suction Material: • Suction device • Fingertip • Sterile suction catheter • Sterile gloves/ unsterile gloves • Storage bowl • Single use apron • Eventually NaCl 0,9 % • Lubricant • Eventually oxygen apparatus Eine Inform at für med ionsbrosch Fachpe izinisches üre rsonal HM.01 AFurther information you can find in our ATMOS respiratory tract information brochure. Please ask for it! Performance: Vacuum adjustment (by adults up to 0.4 bar, by babies and infants up to 0.2 bar) Put on...
Abrir o catálogo na página 16
ATMOS Plak-Vac Disposable suction hose with connector (optional accessory) Oval opening for the fingertip (deepening) to regulate the suction performance Are you worried about the safety of your patients during oral hygiene? With coma vigil and bedridden patients it is always a risk to perform oral hygiene. Any choking of the patient must be prevented. Furthermore it is essential that the rinsing solution is extracted from the patient‘s mouth.. In former times only a simple toothbrush was available but today - thanks to technical progress - many accessories are at hand. ATMOS has the...
Abrir o catálogo na página 17Todos os catálogos e folhetos técnicos ATMOS MedizinTechnik
-
ATMOS LS 31 LED
4 Páginas
-
ATMOS Video Otoscope
4 Páginas
-
ATMOS HL 21 LED
12 Páginas
-
ATMOS TYMP 31
4 Páginas
-
Hygrotherm plus
4 Páginas
-
ATMOS Twin Record 55
3 Páginas
-
i View COLPO
20 Páginas
-
Endoscopes
2 Páginas
-
CLAR
4 Páginas
-
iQam
12 Páginas
-
C 361
24 Páginas
-
S 351
16 Páginas
-
41 gyne
12 Páginas
-
Respiratory tract suction
20 Páginas
-
S 351 Natal
20 Páginas
-
scope
2 Páginas
-
i View 21/31
4 Páginas
-
S 61 Servant
24 Páginas
-
ATMOS® Cardiothoracic Drainage
16 Páginas
-
ATMOS® 360° diagnostics
7 Páginas
-
RS 221 HNO
12 Páginas
-
LC 27
16 Páginas
-
ATMOS® FEES PORTABLE
12 Páginas
-
ATMOS® i View PRO
11 Páginas
-
ATMOS Endoscopy / Stroboscopy System
1 Páginas
-
ATMOS Scope
8 Páginas
-
ATMOS i View 21/31 ENT
20 Páginas
-
ATMOS Hygiene Program
16 Páginas
-
ATMOS® S 351
16 Páginas
-
ATMOS Diagnostic Cube
12 Páginas
-
ATMOS S 61 Servant
32 Páginas
-
ATMOS Chairs
12 Páginas
-
ATMOS Cam 21 / Cam 31 / ATMOSoft ENT 41
16 Páginas
-
ATMOS C 451 / C 361
28 Páginas
-
ATMOS C 11 Systema
16 Páginas
-
Atmoport N
8 Páginas
-
ATMOS Strobo 21 LED
8 Páginas
-
ATMOS S 351
16 Páginas
-
ATMOS Thoraxdrainage-Systeme
20 Páginas
-
Surgery general
80 Páginas
-
Gyne general
72 Páginas
-
ENT general
248 Páginas
-
Care general
77 Páginas
Catálogos arquivados
-
ATMOS C 21 / C 31
32 Páginas
-
ATMOS S 41
1 Páginas
-
ATMOSAFE
8 Páginas
-
ATMOS RS 221 ORL
2 Páginas
-
ATMOS S / E 201 Thorax
6 Páginas