smoke evacuation SUCtion SVStem RF / HF / Laser surgery without smoke Danger for doctor and patient!
Abrir o catálogo na página 1Smoke evacuation | Performance AtmoSafe The smoke evacuation system for a free view in the OT! AtmoSafe - for the safe HF- and Laser surgery! ATMOS has introduced a smoke evacuation system for the OT – the AtmoSafe – a device which is used mainly in the laser and aesthetic surgery. Electrosurgical cutting and coagulation develop toxic fumes and build up unpleasant smells in the operating field - an obscured view and health risks are the result. The smoke evacuation system AtmoSafe protects both staff and patients from these toxic fumes, to the extent that doctors have a clear view in the...
Abrir o catálogo na página 2Smoke evacuation | Performance Main filter unit Pre-filter (HEPA) for a longer service life of the main filter Measures the airflow of the filter and defines the filter life, which is normally more than 35 hours. It consists of ULPA filter, three activated carbon filter layers and a gas filter. Pre-adjustments Clip-on handle The value for operation suction, basic suction and the follow-up time are individually adjustable. By pressing the scroll button the requested parameter to be adjusted, is selected. for slim-line handpieces Start button, manual Stop button, manual Suction performance...
Abrir o catálogo na página 3Smoke evacuation | Product Data Atmosafe User package and accessories The smoke evacuation system for electroand laser surgery! Prevents obnoxious smells Removes airborne particles, viruses, gases, and carcino-genic substances Creates a clear view in the operating field Directly from the manufacturer! AtmoSafe OT set 230 V~/50/60 Hz Microprocessor-controlled suction unit for removing and filtering surgical smoke, incl. internal synchronous activation (ISA), automatic shut-down, filter control and electronically controlled brushless blower. REF 445.0075.0 Scope of delivery: basic device,...
Abrir o catálogo na página 4Smoke evacuation | Consumables 2 Consumables REF Main filter (ULPA) (ULPA 99,9999%@0,01µm / 3-steps gas filter), with electronically controlled service life, Change: after approx. 150 patients 445.0040.0 Prefilter (HEPA) with connections Ø 22 mm (M/F), sterile, 50 pcs., to be used during laser ablations, Change: 1 x per patient 445.0044.0 Air suction handle for monopolar slim-line surgery, clip-on handle, air hose Ø 10 mm, L = 2.5 m, sterile, 25 pcs., Change: 1 x per patient 445.0063.0 Funnel, flattened on one side, made of PP, with connection for Ø 22 mm autoclave-safe up to 134 °C Change:...
Abrir o catálogo na página 5Smoke evacuation | Product Data Atmosafe Basisausstattung Basic unit REF AtmoSafe, 230 V~, 50/60 Hz Microprocessor-controlled suction unit for removing and filtering surgical smoke, incl. internal synchronous activation (ISA), automatic shut-down, filter control and electronically controlled brushless blower. Scope of delivery: basic device, operating instruction, mains cable, main filter unit (ULPA), prefilter set (HEPA), suction hose Ø 22 mm, L = 2,10 m (50 times autoclavable), extraction tube, pipe, hose connector from Ø 22 mm to Ø 22 mm, hose connector from Ø 22 mm (M) to Ø 10 mm (M),...
Abrir o catálogo na página 6Smoke evacuation | Application information Surgical smoke evacuation for the electrical (HF-laser) incision The situation: Electrosurgical devices and lasers for the coagulation of tissue are nowadays part of the standard procedure and operating processes can no longer be imagined without these instruments. aerosols aggregates agglomerates secondary particles Arising problems: Unfortunately these surgical inventions are often accompanied by considerable disadvantages. The application of electrosurgery leads to the formation of toxic gases, harmful aerosols and transmission of human viruses...
Abrir o catálogo na página 7Smoke evacuation | Application information Frequently asked questions on the smoke evacuation problem 1. Is normal operating theatre ventilation adequate for evacuating smoke? No, the rate of air circulation in the room - up to 24 x volume/hour - is not sufficient to evacuate locally generated aerosols and gases; the user is still exposed to dangerous laser smoke. 2. So a normal room suction system (a central vacuum) is not good enough? No, the rate of room suction in an operating theatre is too low, at 30-40 l/min. Research has shown that a minimum of 400-600 l/min. is required in the...
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos ATMOS MedizinTechnik
-
ATMOS LS 31 LED
4 Páginas
-
ATMOS Video Otoscope
4 Páginas
-
ATMOS HL 21 LED
12 Páginas
-
ATMOS TYMP 31
4 Páginas
-
Hygrotherm plus
4 Páginas
-
ATMOS Twin Record 55
3 Páginas
-
i View COLPO
20 Páginas
-
Endoscopes
2 Páginas
-
CLAR
4 Páginas
-
iQam
12 Páginas
-
C 361
24 Páginas
-
S 351
16 Páginas
-
41 gyne
12 Páginas
-
Respiratory tract suction
20 Páginas
-
S 351 Natal
20 Páginas
-
scope
2 Páginas
-
i View 21/31
4 Páginas
-
S 61 Servant
24 Páginas
-
ATMOS® Cardiothoracic Drainage
16 Páginas
-
ATMOS® 360° diagnostics
7 Páginas
-
RS 221 HNO
12 Páginas
-
LC 27
16 Páginas
-
ATMOS® FEES PORTABLE
12 Páginas
-
ATMOS® i View PRO
11 Páginas
-
ATMOS Endoscopy / Stroboscopy System
1 Páginas
-
ATMOS Scope
8 Páginas
-
ATMOS i View 21/31 ENT
20 Páginas
-
ATMOS Hygiene Program
16 Páginas
-
ATMOS® S 351
16 Páginas
-
ATMOS Diagnostic Cube
12 Páginas
-
ATMOS S 61 Servant
32 Páginas
-
ATMOS Chairs
12 Páginas
-
ATMOS Cam 21 / Cam 31 / ATMOSoft ENT 41
16 Páginas
-
ATMOS C 451 / C 361
28 Páginas
-
ATMOS C 11 Systema
16 Páginas
-
Atmoport N
8 Páginas
-
ATMOS Strobo 21 LED
8 Páginas
-
ATMOS S 351
16 Páginas
-
ATMOS Thoraxdrainage-Systeme
20 Páginas
-
Surgery general
80 Páginas
-
Gyne general
72 Páginas
-
ENT general
248 Páginas
-
Care general
77 Páginas
Catálogos arquivados
-
ATMOS C 21 / C 31
32 Páginas
-
ATMOS S 41
1 Páginas
-
ATMOS RS 221 ORL
2 Páginas
-
ATMOS S / E 201 Thorax
6 Páginas