Excertos do catálogo
A big step in the fight against HeART ATTACK AND STROKE: boso ABI-system 100 Arteriosclerosis seen in time – and economically. PWV measurement option. Premium quality boso Germany Top quality for doctors and clinics
Abrir o catálogo na página 1boso ABI-system 100 Decisive: The ankle brachial index boso ABI-s The ankle brachial index. Arteriosclerosis seen in time. The ankle brachial index is the best predictor of heart attack, stroke and mortality. An ABI reading of < 0.9, compared with the angiogram as the gold standard, has a sensitivity The easy quick check for the doctor‘s office. of up to 95 % in identifying PAOD, and conversely rules out this condition in healthy people with a specificity of almost 100 %.¹ The getABI study² shows that the prevalence of PAOD among individuals aged over 60 is 20 %. With the boso ABI-system...
Abrir o catálogo na página 2boso ABI-system 100 The boso ABI-system 100 Outstanding: The boso ABI-system. The boso ABI-system offers many benefits for doctors and patients compared to the previous Doppler ultrasound method. Early detection and routine check In the past, tests were only carried out in cases of suspected disease, because the test was time-consuming and expensive. In addition, PAOD often was not detected early enough as it does not cause any symptoms for a long time. The boso ABI-system is an innovative and rapid way of measuring the ankle-brachial index (ABI). This allows to carry out this test on a...
Abrir o catálogo na página 3The sophisticated software accurately calculates the ABI both on the left and on the right side. Other important cardiovascular parameters are also measured, such as individual blood pressure readings in arms and legs, differences in blood pressure on different sides of the body (subclavian artery stenosis), pulse, pulse pressure, oscillation profile and pointers to possible cardiac dysrhythmia disorders. This information is easily identifiable as all critical values are highlighted in a different colours. Difference between sides (subclavian artery stenosis) Pulse pressure Blood pressure...
Abrir o catálogo na página 4Arterial stiffness readings provide useful information about the existence of functional arterial more accurate than classical risk parameters such as blood pressure and age. Pulse wave velocity. For a better management of patients with hypertension, tests for arterial stiffness provide additional information about the cardiovascular risk. The recent guidelines published by the Pulse wave velocity is an additional tool to diagnose PAOD and to measure arterial stiffness. European Society of Hypertension (ESH) and the European Society of Cardiology (ESC) recommend the investigation of...
Abrir o catálogo na página 5Some case examples. SUSPECTED HYPERTENSION SUSPECTED EXTPA SYSTOL ABI/PWV measurement SUSPECTED ATPIAL FIBRILLATION ABI/PWV measurement SewtralliHt Pmwn;l| [* C-\PH)i*ml>i«ftb«iApi^jr«(MWOyff Visit.www.boso-abi.de for more information and downloads
Abrir o catálogo na página 6Some case examples. SIDE DIFFERENCE 11 MMHC- // SUSPECTEP SUBCLAVIAN STENOSIS CFPWV> 10 // V. A HI6H VASCULAP STIFFNESS ABI/PWV iiiesjuieinenl CFPWV = G.7 // LOW VASCULAP STIFFNESS SUSPECTEP PAP ANP HI6H VASCULAP STIFFNESS Visit.www.boso-abi.de for more information and downloads
Abrir o catálogo na página 7The boso ABI-system has undergone clinical assessment comparing it to Doppler-assisted ABI measurement, and was found to be superior. The study was published by Swiss Medical Weekly on 26 June 2009 and can be downloaded or at our special website www.boso-abi.de Oscillometric measurement of ankle-brachial index in patients with suspected peripheral vascular disease: comparison with Doppler jVWflf Diebt/f \ Pierian Dic&"\ Cursten Cznpritt*t Udgtr ijnzall*, Iris Baiangartner", Curt Diebitt1 Swiss Cardiovascular Centre, Division of Clinical and Interventional Angiology" and CjtnJimascular...
Abrir o catálogo na página 8Subject to technical changes. No liability for misprints. | 06/2014 Bosch + Sohn GmbH u. Co. KG Bahnhofstraße 64 D-72417 Jungingen T + 49 (0) 74 77 92 75 - 0 F + 49 (0) 74 77 10 21 E zentrale @ boso.de www.boso.de www.boso-abi.de/en Top quality for doctors and clinics
Abrir o catálogo na página 9Todos os catálogos e folhetos técnicos Boso
-
bp-monitoring is boso.
28 Páginas
-
Presentation boso TM-2450
32 Páginas
-
boso medicus X
18 Páginas
-
1x1_blood_pressure_measurement
8 Páginas
Catálogos arquivados
-
TM-2430 PC 2
5 Páginas
-
Warmth wellness
8 Páginas
-
Thermometers
2 Páginas
-
Aneroid Sphygmomanometers Stethoscopes
28 Páginas
-
ABI-system 100
9 Páginas
-
Leaflet blood pressure instruments
13 Páginas
-
boso TM-2430 PC 2
5 Páginas
-
Stethoscopes
28 Páginas
-
boso ABI-system 100
7 Páginas
-
boso TM-2430 PC 2 Old
8 Páginas
-
Blood pressure monitors for doctors - EN
15 Páginas
-
Mercury-like blood pressure monitor
5 Páginas