Quant Proteomics
1 / 8Páginas

Excertos do catálogo

Quant Proteomics - 1

Designed for Accuracy High resolution quantitative proteomics Innovation with Integrity

Abrir o catálogo na página 1
Quant Proteomics - 2

Setting New Standards in Accuracy The development of mass spectrometry based proteomics approaches has dramatically improved researchers‘ capabilities of characterizing the protein content of biological systems, while simultaneously offering information on proteins identity, abundance and modifications. Accurate and reproducible protein quantitation is key for success and Bruker’s latest UHR-QTOF platforms are designed to provide the best performance in this area. The Instant Expertise™ acquisition methods provide easy and straightforward access to the underlying biology. Generic...

Abrir o catálogo na página 2
Quant Proteomics - 3

Accuracy = Resolution x Sensitivity Full Sensitivity Resolution (FSR) In traditional QTOF architecture, high resolution is obtained at the price of ion losses through slits or multiple reflections and the maximal sensitivity is therefore not accessible at full resoultion. The Bruker FSR architecture, in contrast, makes use of the maximum number of ions to obtain the highest resolution available without sensitivity loss. This ensures the best possible selectivity and sensitivity, at any speed. Whatever strategy is chosen for quantitative mass spectrometry based analysis of complex proteomics...

Abrir o catálogo na página 3
Quant Proteomics - 4

Repeatable High Performance The impact ll's unique combination of sensitive, high resolution and high dynamic range spectra opens a new dimension in MS based quantitation. Both label-free quantitation workflows and quantitation based on chemical labels are very easy to implement with pre-set methods. Preservation of spectral quality in MS/MS mode guarantees optimal performance for these data dependant acquisition (DDA) approaches. Instant Expertise™ The impact ll's default ID/Quant acquisi- tion method ensures accurate MS based quantitation with regular spacing of MS The number of MS/MS...

Abrir o catálogo na página 4
Quant Proteomics - 5

Across the Whole Range The impact II allows targeted proteomics experiments to be run in either an MS based format or at the MS/MS level based on data independent acquisition (DIA). Superior resolution and full sensitivity of MS and MS/MS spectra facilitate both approaches on Data aquisition in MS mode for targeted peptide and protein quantitation provides accurate results over a large dynamic range based on high resolution extracted This mode is applicable to both high and low complexity samples and both approa- ches benefit from the uncompromised resolution and sensitivity of the impact...

Abrir o catálogo na página 5
Quant Proteomics - 6

Label-Free Intact Protein Analysis Peptide based quantitation is a very sensitive approach but it is blind to some essential biological events such as protein proteolysis. By combining Full Sensitivity Resolution with the True Isotopic Pattern (TIP™) capability of Bruker’s UHR-QTOF systems, accurate measurement of intact proteins is readily available, even in complex mixtures. The Dissect™ and SNAP™ algorithms extract the accurate mass and intensity information to perform a direct label free approach on intact proteins. Dissect™ Dissect™ processing of an E.Coli lysate separated with a 20...

Abrir o catálogo na página 6
Quant Proteomics - 7

Label-Free Shotgun Proteomics Accuracy of the label free quantitation (ID/Quant) workflow Thanks to the combination of very stable nano electrospray (CaptiveSpray™) and advanced QTOF technology, the impact II offers robust and accurate label- free quantitation. Since this strategy relies on every single peptide precursor ion that is detected at the MS level, the benefit of high resolution over the entire mass range directly translates into superior ratio Peak intensity Quant accuracy over a large dynamic range spread over L.FQ intensity sample 1 (toglDj 500 ng of yeast digest were spiked...

Abrir o catálogo na página 7
Quant Proteomics - 8

Verified by Science The impact II provides latest Bruker UHR-QTOF technology The unique combination of quantitative accuracy, dynamic range and reproducibility make the system capable of delivering quantitative data with best accuracy. Full-Sensitivity-Resolution Technology • 50,000 resolving power at MS and MS/MS level without compromising sensitivity or acquisition speed • Highly accurate extracted ion chromatogram (1-2 mDa) CaptiveSpray nanoBooster Source • Zero adjustment for excellent reproducibility • Acetonitril dopant for improved sensitivity Collision Cell 50 Gbit/s Detection...

Abrir o catálogo na página 8

Todos os catálogos e folhetos técnicos Bruker Daltonics Inc.

  1. IntelliSlidesTM

    2 Páginas

  2. CMC-assist

    2 Páginas

  3. Toxtyper

    8 Páginas

  4. Product Overview

    16 Páginas

  5. spotOn™

    4 Páginas

  6. Metabolomics

    8 Páginas

  7. TASQ Software

    4 Páginas

  8. timsTOF™

    8 Páginas

  9. TargetScreener

    6 Páginas

  10. timsTOF Pro

    6 Páginas

  11. MBT Galaxy RUO

    4 Páginas

  12. MBT Pilot RUO

    4 Páginas

  13. MBT SMART IVD

    4 Páginas

  14. MBT Sepsityper

    6 Páginas

  15. MBT BTS US

    2 Páginas

  16. MBT Pharma

    8 Páginas

  17. MALDI Imaging

    16 Páginas

  18. ProteinScape

    8 Páginas

  19. maxis II

    12 Páginas

  20. EVOQ

    6 Páginas

  21. impact II

    12 Páginas

  22. micrOTOF II

    8 Páginas

  23. ImagePrep

    4 Páginas

  24. DE-tector

    6 Páginas

  25. pTD

    2 Páginas

  26. RAID AFM

    4 Páginas

  27. RAID XP

    4 Páginas

  28. RAID S2

    6 Páginas

  29. RAID M100

    6 Páginas

  30. MM2

    6 Páginas

  31. SVG 2 and Probes

    6 Páginas

  32. µRAID

    4 Páginas

  33. VeroTect

    4 Páginas

  34. SIGIS II

    2 Páginas

  35. solarix XR

    12 Páginas

  36. Product Overview

    20 Páginas

  37. impact HD

    12 Páginas

  38. Toxtyper

    6 Páginas

  39. micrOTOF-Q III

    6 Páginas

Catálogos arquivados

  1. EVOQ - 2014

    6 Páginas