rapifleX™ MALDI Tissuetyper™
1 / 8Páginas

{{requestButtons}}

Excertos do catálogo

rapifleX™ MALDI Tissuetyper™ - 1

rapifleX™ MALDI Tissuetyper™ For Mass Spectrometric Imaging Innovation with Integrity

Abrir o catálogo na página 1
rapifleX™ MALDI Tissuetyper™ - 2

MALDI Tissuetyper™ Speed | Robustness | Definition The rapifleX instrument re-defines the key performance measures for MALDI Imaging: • Up to 50 true pixels / second for faster and better images • smartbeam™ 3D laser for better pixel-to-pixel reproducibility • Pixel size < 10µm for highest spatial resolution to retrieve biological information • Novel ion source design for increased robustness Lipids in rat testis, pixel size 10 µm, 395000 pixels, 200 shots per pixel, measurement time 165 minutes.

Abrir o catálogo na página 2
rapifleX™ MALDI Tissuetyper™ - 3

Laser and Ion Source Designed for MALDI Tissue Typing smartbeam™ 3D laser During the image acquisition the sample stage moves continually to achieve high pixel rates. The newly developed smartbeam™ 3D laser fires at a repetition rate of up to 10 kHz. The new smartbeam™ 3D laser features a laser diameter of 5µm. As illustrated below, the laser can move independently from the sample stage to scan the full area of each pixel. This produces truly square pixels which utilizes all of the available sample area for maximum sensitivity and pixel-to-pixel reproducibility. Ablated matrix showing...

Abrir o catálogo na página 3
rapifleX™ MALDI Tissuetyper™ - 4

Novel Ion Source Design for Robust Day-to-Day Operation Extends uptime between cleaning by orders of magnitude. Easy access to self-aligning ion lenses when cleaning is in fact needed. The whole lens pack can be rinsed • with Ethanol. Proteins in sagittal rat brain section measured at 30 µm pixel size, ~150000 pixel.

Abrir o catálogo na página 4
rapifleX™ MALDI Tissuetyper™ - 5

Leading Software for MALDI Tissuetyper flexImaging allows to set up and analyze individual datasets. • • • • • Wizard driven user-friendly set up of new experiments True 64-bit application allows efficient handling of megapixel datasets Direct access to single mass spectra Batch acquisition Co-register and super-impose virtual microscopic slides at full resolution for detailed histological annotation MALDI Imaging data overlaid with virtual microscopic slide in flexImaging SCiLS Lab statistical analysis software for mining MALDI Tissuetyper data. It allows both the analysis of individual...

Abrir o catálogo na página 5
rapifleX™ MALDI Tissuetyper™ - 6

Tissue Typing - A Clinical Discovery Workflow Tissue samples are measured in the rapifleX MALDI Tissuetyper. MALDI Imaging dataset overlaid with micro- scopic image allows detailed annotation. Tissue is histologically stained after Tissue is scanned in a microscopic slide MzRange Pipeline-Aligned-Peafcs (ply Project) Centraid - Pipelin ± - Pipeline-Aligr p-Value - l-test Rating - t-test Statistical analysis of MALDI Tissuetyper data in SCiLS Lab.

Abrir o catálogo na página 6
rapifleX™ MALDI Tissuetyper™ - 7

rapifleX MALDI Tissuetyper™ – Designed for MALDI Imaging Integrated software solutions • MALDI time-of-flight system • New ion source for robust day-to-day operation • Novel smartbeam™ 3D laser • Fast acquisition of up to 50 true square pixel / second • Laser repetition rate 10 kHz • Pixel size <10µm flexImaging dedicated molecular histology software controls data acquisition, data visualization, annotation and integration of virtual microscopic slides SCiLS Lab is the dedicated software for statistical analysis. From individual imaging datasets to complete clinical biomarker studies, it...

Abrir o catálogo na página 7
rapifleX™ MALDI Tissuetyper™ - 8

rapifleX MALDI Tissuetyper™ – Customer Feedback “The ideal imaging MS system needs high data acquisition speeds, high spatial resolution capabilities, and high mass resolving power. With this new system, Bruker re-imagined the MALDI source and laser optics to deliver very impressive performance and information throughput. This is a revolutionary instrument which has the potential to significantly improve sample throughput and offer useful information in real time in clinical research.” Dr. Pierre Chaurand, Associate Professor, Université de Montréal, Canada “Translational clinically...

Abrir o catálogo na página 8

Todos os catálogos e folhetos técnicos Bruker Daltonics Inc.

  1. IntelliSlidesTM

    2 Páginas

  2. CMC-assist

    2 Páginas

  3. Toxtyper

    8 Páginas

  4. Product Overview

    16 Páginas

  5. spotOn™

    4 Páginas

  6. Metabolomics

    8 Páginas

  7. TASQ Software

    4 Páginas

  8. timsTOF™

    8 Páginas

  9. TargetScreener

    6 Páginas

  10. timsTOF Pro

    6 Páginas

  11. Quant Proteomics

    8 Páginas

  12. MBT Galaxy RUO

    4 Páginas

  13. MBT Pilot RUO

    4 Páginas

  14. MBT SMART IVD

    4 Páginas

  15. MBT Sepsityper

    6 Páginas

  16. MBT BTS US

    2 Páginas

  17. MBT Pharma

    8 Páginas

  18. MALDI Imaging

    16 Páginas

  19. ProteinScape

    8 Páginas

  20. maxis II

    12 Páginas

  21. EVOQ

    6 Páginas

  22. impact II

    12 Páginas

  23. micrOTOF II

    8 Páginas

  24. ImagePrep

    4 Páginas

  25. DE-tector

    6 Páginas

  26. pTD

    2 Páginas

  27. RAID AFM

    4 Páginas

  28. RAID XP

    4 Páginas

  29. RAID S2

    6 Páginas

  30. RAID M100

    6 Páginas

  31. MM2

    6 Páginas

  32. SVG 2 and Probes

    6 Páginas

  33. µRAID

    4 Páginas

  34. VeroTect

    4 Páginas

  35. SIGIS II

    2 Páginas

  36. solarix XR

    12 Páginas

  37. Product Overview

    20 Páginas

  38. impact HD

    12 Páginas

  39. Toxtyper

    6 Páginas

  40. micrOTOF-Q III

    6 Páginas

Catálogos arquivados

  1. EVOQ - 2014

    6 Páginas