timsTOF Pro
1 / 6Páginas

{{requestButtons}}

Excertos do catálogo

timsTOF Pro - 1

timsTOF Pro powered by PASEF and the Evosep One for high speed and sensitive shotgun proteomics The “Parallel Accumulation Serial Fragmentation” (PASEF) method for trapped ion mobility spectrometry (TIMS) quadrupole time of flight (QTOF) instruments described previously [1] enables faster acquisition of fragment ion spectra from isolated precursor ions, without sacrificing spectral quality. Introduction During an ion mobility scan the quadrupole switches its isolation position several times, isolating a certain ion species only for the period of time it actually elutes from the mobility separation device as a focused package (Figure 1). With further hardware and software improvements, PASEF has been fully implemented on a new QTOF based instrument, the timsTOF Pro, which was used to produce the results presented here. Precursor selection in two dimensions occurs in multiple steps: • coarse detection of intensities in the mz/mobility pane • extract MS spectra around intensities found • refine and correct isolation position Authors: Heiner Koch 1, Scarlet Beck 1, Markus Lubeck 1, Oliver Raether 1 and Gary Kruppa 2. 1  Bruker Daltonik GmbH, Bremen, Germany; 2 Bruker Daltonics Inc, Billerica, USA • filter for precursors detected more than once • filter by 2D dynamic exclusion list When the final list is compiled, individual precursors have to be distributed among the following PASEF fragmentation scans in the most efficient way. The optimal order of measurements would correspond to the shortest itinerary Keywords: PASEF, timsTOF Pro, TIMS, clinical

Abrir o catálogo na página 1
timsTOF Pro - 2

in a classical 'travelling salesman problem' which cannot be calculated on an LC timescale. A non-perfect but fast (~ 1 ms per full cycle) approach was implemented which also takes into account that low intensity precursors have to be scheduled multiple times to obtain meaningful fragment spectra (Figure 2). Methods Hela cells (CIL Biotech, Mons, Belgium) were digested using the protocol from Wang et al. [ 2]. Chromatographic separations were performed on a nanoE-lute (Bruker Daltonics) using a 25 cm, 75 pm ID Odyssey C18 nano column with integrated emitter (lonOpticks, Australia) at 400...

Abrir o catálogo na página 2
timsTOF Pro - 3

Number of precursor ions fragmented per PASEF scan 12000 12000 Number of precursor ions fragmented per PASEF frame Figure 3: Distribution of the number of precursor ions fragmented per PASEF MS/MS scan during a 90 min LC autoMS/MS gradient (200 ng HeLa digest). On average 12.6 precursors are addressed during a 100 ms PASEF scan, resulting in > 100 Hz acquisition speed. However, due to the 100 ms accumulation time, the signal intensity per fragment spectrum is still comparable to a 10 Hz acquisition. Number of repetitive measurements per precursor 100000 100000 2 3 4 5 6 7 8 9 10 Figure 4:...

Abrir o catálogo na página 3
timsTOF Pro - 4

Mascot Mascot Mascot/Percolator Mascot/Percolator Byonic Byonic Unique peptide sequences 60160 Figure 5: Peptide identification results from different search engines for 200 ng HeLa digest separated by 90 min gradients (average numbers from triplicate runs). Mascot Mascot 0 Unique peptide sequences Mascot/Percolator Mascot/Percolator Protein groups Byonic Byonic Gradient length Gradient length Figure 6: Peptide identification results (Mascot/Percolator) for 200 ng HeLa digest separated by LC gradients of 30, 45, 60 and 90 minutes, using the nanoElute (Bruker Daltonics).

Abrir o catálogo na página 4
timsTOF Pro - 5

# PSMs # PSMs # PSMs # PSMs # Proteins # Proteins # Proteins # Proteins # Proteins # Proteins Identified Identified Identified Identified Quantified Quantified Quantified Quantified 20 80 runs in less than 10h measurement time! Reproducible ID results and reproducible TIC intensities. Figure 7: Peptide and protein identification and quantification results (using PEAKS studio) for 50 ng HeLa digest separated by LC gradients of 5 minutes on an Evosep One. Even with a 5 minute gradient, almost 8000 unique PSM’s, and over 1400 proteins could be identified with more than 1000 proteins...

Abrir o catálogo na página 5
timsTOF Pro - 6

Learn More You are looking for further Information? Check out the link or scan the QR code. For research use only. Not for use in diagnostic procedures. Bruker Daltonik GmbH Bremen · Germany Phone +49 (0)421-2205-0 Fax +49 (0)421-2205-103 ms.sales.bdal@bruker.com – www.bruker.com to change specifications without notice. © Bruker Daltonics 04-2018, PN-52 [1] Meier et al, J Proteome Res.,2015; 14(12); 5378-87 [2] Wang et al, J Proteome Res., 2005; 4(6); 2397-2403 Bruker Daltonics is continually improving its products and reserves the right

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos Bruker Daltonics Inc.

  1. IntelliSlidesTM

    2 Páginas

  2. CMC-assist

    2 Páginas

  3. Toxtyper

    8 Páginas

  4. Product Overview

    16 Páginas

  5. spotOn™

    4 Páginas

  6. Metabolomics

    8 Páginas

  7. TASQ Software

    4 Páginas

  8. timsTOF™

    8 Páginas

  9. TargetScreener

    6 Páginas

  10. Quant Proteomics

    8 Páginas

  11. MBT Galaxy RUO

    4 Páginas

  12. MBT Pilot RUO

    4 Páginas

  13. MBT SMART IVD

    4 Páginas

  14. MBT Sepsityper

    6 Páginas

  15. MBT BTS US

    2 Páginas

  16. MBT Pharma

    8 Páginas

  17. MALDI Imaging

    16 Páginas

  18. ProteinScape

    8 Páginas

  19. maxis II

    12 Páginas

  20. EVOQ

    6 Páginas

  21. impact II

    12 Páginas

  22. micrOTOF II

    8 Páginas

  23. ImagePrep

    4 Páginas

  24. DE-tector

    6 Páginas

  25. pTD

    2 Páginas

  26. RAID AFM

    4 Páginas

  27. RAID XP

    4 Páginas

  28. RAID S2

    6 Páginas

  29. RAID M100

    6 Páginas

  30. MM2

    6 Páginas

  31. SVG 2 and Probes

    6 Páginas

  32. µRAID

    4 Páginas

  33. VeroTect

    4 Páginas

  34. SIGIS II

    2 Páginas

  35. solarix XR

    12 Páginas

  36. Product Overview

    20 Páginas

  37. impact HD

    12 Páginas

  38. Toxtyper

    6 Páginas

  39. micrOTOF-Q III

    6 Páginas

Catálogos arquivados

  1. EVOQ - 2014

    6 Páginas