Excertos do catálogo

Ultra High Efficiency Single Package Gas Heating/Electric Cooling Commercial Rooftop Units with Puron® (R-410A) Refrigerant Product Data DEALER DESIGN Editors Choice the environmentally sound refrigerant Copyright 2010 Carrier Corp. • 7310 W. Morris St • Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 9/10 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Abrir o catálogo na página 1
Easy Installation PAGE FEATURES/BENEFITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . 6 AHRI CAPACITY RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . . 7 OPERATION AIR QUANTITY LIMITS . . . . . . . . . . . . . . . . 10 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 OPTIONS AND ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . 14 BASE UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 16 ACCESSORY DIMENSIONS . . . . . . . . . . . . . . . . . ....
Abrir o catálogo na página 2
Carrier’s 48PM rooftop units include microchannel technology condenser coils. Microchannel technology provides many performance and reliability benefits, that results in a more compact coil design with high coil and overall unit efficiencies. In addition, the surface of the coil is much more robust than a conventional round tube plate fin copper tube aluminum fin coil. S 0.3 fins/inch S 18 louvers per fin S 32 ports per tube (high ratio of internal wetted perimeter to flow area) S Double wall thickness on exposed tube edges S All aluminum coil S Furnace-brazed coil S Epoxy-lined shrink wrap...
Abrir o catálogo na página 3
Indoor Air Quality Begins With Carrier Rooftops Two-in. disposable filters are factory furnished as standard in every unit with the capability of accommodating 4-in. filters with Factory Option as well as factory-installed MERV- pleated -8 filters. Internally sloped condensate pans are self-draining to ensure minimizing biological growth in rooftop units in accordance with ASHRAE Standard 62. All 48PM16-28 units use an epoxy powder-coated steel condensate pan. Unit uses foil-faced cleanable insulation that is securely fastened. Selected panels are mechanically fastened for added support....
Abrir o catálogo na página 4
ComfortLinkt Control Option The ComfortLink control is your link to a world of simple and easy to use rooftop units that offer outstanding performance and value. When used with a space temperature sensor, the ComfortLink controls’ intelligence maintains control over the economizer and condenser fans and optimizes the performance of the refrigeration circuits as conditions change resulting in the following features: S Better control of temperature and humidity S Superior reliability S Automatic redundancy S Low ambient cooling operation to 0_F S More accurate diagnostics, at unit or remote...
Abrir o catálogo na página 5
MODEL NUMBER NOMENCLATURE 48PM Product Series Type 48PM --- Single Packaged CV Rooftop Unit with PuronR Refrigerant and Gas Heat Gas Heat Options D --- Low Heat Standard Heat Exchanger E --- Medium Heat Standard Heat Exchanger F --- High Heat Standard Heat Exchanger L* --- Low Heat Stainless Steel Heat Exchanger M* --- Medium Heat Stainless Steel Heat Exchanger N* --- High Heat Stainless Steel Heat Exchanger Factory--- Installed Options Base Unit Control Type C --- ComfortLinkt DDC Controls M --- Electro--- Mechanical Controls EnergyXt Options*** --- --- Standard, No EnergyX E --- Low CFM...
Abrir o catálogo na página 6
AHRI* CAPACITY RATINGS LEGEND ASHRAE dB EER IPLV ENGLISH Units Btu/h kW Btu/h/W Btu/h/W ft^3/min --- American Society of Heating, Refrigeration and Air Conditioning Engineers --- Decibel --- Energy Efficiency Ratio --- Integrated Part---Load Values *Air Conditioning, Heating and Refrigeration Institute. **IPLV values are calculated based on control configuration T.CTL = 2 (2 Stage Y1). {Size 28 unit is not listed with AHRI, but is tested to AHRI Standards. NOTES: 1. Tested in accordance with AHRI Standards 360 ---95 (18 ---28 sizes). 2. Ratings are net values, reflecting the effects of...
Abrir o catálogo na página 7
Heating Capacities and Efficiencies — 48PM 16-28 Vertical and Horizontal Supply Units (Natural Gas) - Three Phase Standard Stainless Steel HEATING INPUT Stage 2 (Btuh) HEATING INPUT Stage 1 (Btuh) OUTPUT CAPACITY Stage 2 (Btuh) THERMAL EFFICIENCY (%) LEGEND AFUE ASHRAE Annual Fuel Utilization Efficiency American Society of heating, Refrigeration and Air Conditioning Engineers Liquid Propane * Minimum Heating cfm must be maintained to ensure proper heating operation. NOTES: 1. Minimum allowable temperature of mixed air entering the heat exchanger during first stage heating is 45_F. Both...
Abrir o catálogo na página 8
Altitude Compensation* — 48PM16- (Natural Gas) -28 ELEVATION (FT) * As the height above sea level increases, there is less oxygen per cubic foot of air. Therefore, heat input rate should be reduced at higher altitudes. Includes a 4% input reduction per each 1000 ft. { Orifices available through your local Carrier dealer. MEDIUM HEAT * As the height above sea level increases, there is less oxygen per cubic foot of air. Therefore, heat input rate should be reduced at higher altitudes. Includes a 4% input reduction per each 1000 ft. { Orifices available through your local Carrier dealer. *...
Abrir o catálogo na página 9
OPERATION AIR QUANTITY LIMITS 48PM Heating Operational CFM Limits COOLING High Heat (8 Cell) Medium Heat (8 Cell) Low Heat (5 Cell) High Heat (8 Cell) Medium Heat (8 Cell) Low Heat (5 Cell) High Heat (8 Cell) Medium Heat (8 Cell) Low Heat (5 Cell) High Heat (8 Cell) Medium Heat (8 Cell) Low Heat (5 Cell) *7000 cfm minimum recommended above 1.0 in. wg external static pressure. Outdoor Sound Power (Total Unit) OCTAVEBANDS LEGEND AHRI --- Air Conditioning, Heating and Refrigeration Institute NOTES: *Indoor sound power is available in Carrier’s Electronic Catalog Program for specific operating...
Abrir o catálogo na página 10
PHYSICAL DATA Physical Data - 48PM16-28 High Heat Medium Heat * Aluminum evaporator coil/aluminum condenser coil with low heat Round Tube Plate Fin 4 4 15 15 23.1 23.1 Balanced-Port TXV w/ bypass Round Tube Plate Fin amps in. in. wg. psig total deg F deg F ** For applications less than 2000 ft elevation *** Vertical application numbers shown. UNIT 48PM DIMENSIONS Length Width Height OPERATING WEIGHT Base unit (50 series) Base unit (48 series, low heat) COMPRESSOR Type Quantity Number of circuits Capacity Stages (%) Circuit 1 - Circuit 2 Oil type Oil quantity Circuit A Circuit B REFRIGERANT...
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos Carrier| Commercial Systems North America
-
WeatherMaker® 50TCQ
116 Páginas
-
INFINITY™ 38MPRA
2 Páginas
-
ActivAIR™ 36CB
24 Páginas
-
ACTIVAIR™ 36IB
44 Páginas
-
Axis™
2 Páginas
-
AHUBuilder
2 Páginas
-
PERFORMANCE™ 50VL-A
6 Páginas
-
50ZPB
4 Páginas
-
PERFORMANCE™ 50VT-A
6 Páginas
-
Carrier® Ductless Systems
8 Páginas
-
39CC
2 Páginas
-
ActivAIR™ Induction Beams
2 Páginas
-
Axis™ Overhead Air Terminals
2 Páginas
-
Aero® 39M Air Handlers
2 Páginas
-
A World of Comfort
2 Páginas
-
i-Vu CCN Router Product Data Sheet
2 Páginas
-
Special Seismic Compliance
1 Páginas
-
Axis ™ Overhead Air Terminals
2 Páginas
-
AQUAZONE? Water Source Heat Pumps
2 Páginas
-
17DA Centrifugal Chiller
2 Páginas
-
Air Handling Units 39 HQ
6 Páginas
-
48P WEATHERMASTER®
168 Páginas
-
48A WEATHERMAKER®
116 Páginas
-
48PG CENTURION?
107 Páginas
-
48TC WEATHERMAKER®
116 Páginas
-
48HC WEATHERMASTER®
124 Páginas
-
48LC WEATHEREXPERT®
52 Páginas
-
48VL Performance? 14
32 Páginas
-
48XL-A
30 Páginas
-
48XL Infinity? 15
26 Páginas
-
OMNIZONE?
80 Páginas
-
16TJ
32 Páginas
-
AQUASNAP® 30MPA,MPW015-045
36 Páginas
-
EVERGREEN® 30HXA,HXC076-271
52 Páginas
-
AQUAFORCE® 30XW150-400
60 Páginas
-
EVERGREEN® 23XRV
32 Páginas
-
AQUAFORCE® 30XA
150 Páginas
-
30RB AQUASNAP®
92 Páginas
-
30RAP AQUASNAP®
88 Páginas
-
39S
36 Páginas
-
39L AERO®
52 Páginas
-
39M AERO®
110 Páginas
-
19XR EVERGREEN®
56 Páginas
-
Aero Air-Handling Units
2 Páginas