Gas Heaters in Carrier’s Aero ® 39M Air H andlers Delivering the Capacity You Need
1 / 2Páginas

Excertos do catálogo

Gas Heaters in  Carrier’s  Aero ® 39M Air H andlers Delivering the Capacity You Need - 1

Gas Heaters in Carrier’s Aero® 39M Air Handlers Delivering the Capacity You Need Indirect Fired Gas Heaters Are available in Carrier’s 39M air handler in sizes 06-110 ranging in capacities from 100 to 6,000 MBH with at least 3 heating input options per unit size. With a minimum standard 10:1 turndown ratio, the 39M gas heaters can match the heat output to a specific load maintaining tight temperature control while minimizing operating costs. Why use a gas heat system? Gas heaters provide a cost effective heating solution from both an initial capital cost as well as a life cycle ownership cost. Unlike hot water or steam heating systems, a gas heat system, by not requiring additional equipment such as boilers and pumps, can avoid additional energy consumption from the heating and conveyance of the fluid or steam. Why use an indirect gas fired system? An indirect gas fired system provides peace of mind as the products of combustion do not come in contact with the re-circulated air. In an indirect fired system, the gas burner is fired into a radiant tube type heat exchanger which is separated from the supply air stream. This system is recommended for all applications as it provides heat without contamination from the by-products of combustion. In contrast, a direct gas fired system will introduce the products of combustion and additional moisture directly into the supply air stream. Direct fired systems are restricted to applications such as large warehouses, manufacturing plants, and other types of commercial/industrial facilities and are not recommended for office buildings, schools or densely populated spaces. Indirect gas fired tubular furnaces in Carrier’s 39M provide:  Induced draft gas heat combustion with inshot burners and a heat exchanger with flue gases under negative pressure  Low airside pressure drop which can reduce the required fan horsepower as compared to drum & tube style heat exchangers  Standard minimum 10:1 turndown ratio with options available up to 60:1  Higher turndown ratios than drum & tube style without the risk of continuous condensation  100% Outside air capability  Standard type 409 stainless steel construction with optional type 304L  Minimum field setup required  Single point gas & electrical supply connections for the gas heater  Control Board with 0-10VDC external input  Integrated operating and safety controls prewired to a sequencer for system control  ETL listed  ANSI Z83.8 (2006) - CSA 2.6M (2006) 

Abrir o catálogo na página 1
Gas Heaters in  Carrier’s  Aero ® 39M Air H andlers Delivering the Capacity You Need - 2

Induced draft with inshot burners This type of burners keeps the flue side under negative pressure on the inside of the heat exchanger pulling out all the products of combustion from the heat exchanger Always in a blow thru arrangement In the event of a heat exchanger failure, this Arrangement minimizes the possibilities of any products of combustion entering the circulating air stream and therefore the heated space The importance of a high turndown ratio The gas heaters in the 39M are available with a minimum turndown ratio of 10:1 with options as large as 60:1 depending on the size of the...

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos Carrier| Commercial Systems North America

  1. WeatherMaker® 50TCQ

    116 Páginas

  2. ActivAIR™ 36CB

    24 Páginas

  3. ACTIVAIR™ 36IB

    44 Páginas

  4. Axis™

    2 Páginas

  5. AHUBuilder

    2 Páginas

  6. 50ZPB

    4 Páginas

  7. 39CC

    2 Páginas

  8. 48P WEATHERMASTER®

    168 Páginas

  9. 48A WEATHERMAKER®

    116 Páginas

  10. 48PG CENTURION?

    107 Páginas

  11. 48PM CENTURION?

    64 Páginas

  12. 48TC WEATHERMAKER®

    116 Páginas

  13. 48HC WEATHERMASTER®

    124 Páginas

  14. 48XL-A

    30 Páginas

  15. 48XL Infinity? 15

    26 Páginas

  16. OMNIZONE?

    80 Páginas

  17. 16TJ

    32 Páginas

  18. EVERGREEN® 23XRV

    32 Páginas

  19. AQUAFORCE® 30XA

    150 Páginas

  20. 30RB AQUASNAP®

    92 Páginas

  21. 30RAP AQUASNAP®

    88 Páginas

  22. 39S

    36 Páginas

  23. 39L AERO®

    52 Páginas

  24. 39M AERO®

    110 Páginas

  25. 19XR EVERGREEN®

    56 Páginas

Catálogos arquivados