Flash Right with FlashTite® The Newest Sealed Container System from Case Medical for sealed immediate use “IUSS” with FDA 510k. Meets AAMI Standards AORN Recommended Practices The Joint Commission regulations with “dry” loads FlashTite, a filterless sealed container system for safe and effective “Flash” Sterilization Validated in independent laboratories using the overkill method: Tested with blades and lumens, mixed loads and 16 lbs. of surgical devices. Sterility maintenance was confirmed for a 24 hour period. However, Case Medical recommends immediate use for all flashed items. State of the art technology: The sealed flash system replaces the current practice of flashing with an open pan or using a sealed container in the lid open position. Safe and effective: The valve automatically opens and closes in the autoclave avoiding the need for staff to manually vent steam, and lessens the potential for injury due to burns. Ease of use: Simply place the instruments in the basket, seal and sterilize. T ransport sealed to point of use. FlashTite'Filter-less container specifications Containers with GV suffix must be used for gravity displacement steam cycles. Flash Tite baskets are designed to clear the valve in base and lid. Healthcare professionals can now rapidly sterilize surgical instruments and medical devices in gravity displacement or prevacuum IUSS cycles utilizing the filter-less SteriTite sealed container with the added FlashTite valve plate(s). 19 Empire Blvd. South Hackensack, NJ 07606 .Phone 201-313-1999 .Fax 201-373-9090 .www.casemed.com

Abrir o catálogo na página 1
Case Medical’s FlashTite Container system - 2

Case Medical, Inc. recommends that the user refer to the sterilizer manufacturer’s “Instructions for Use” for specific information as to the limitations of instrumentation, specifications and material compatibility. Further review the SteriTite container with FlashTite valve plate(s) labeling as to cautions in regard to use in gravity displacement IUSS or pre-vacuum IUSS steam sterilization. The SteriTite container with FlashTite valve plate was specifically designed and tested for use in IUSS cycles in conformance with AAMI ST 77 (2006) & AAMI ST 79(2010/12). 1. Clean , rinse and dry...

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos Case Medical

  1. Software

    2 Páginas

  2. Chemistry

    4 Páginas

  3. case carts

    1 Páginas