Endovascular Aortic Repair - Abdominal
1 / 24Páginas

Excertos do catálogo

Endovascular Aortic Repair - Abdominal - 1

Endovascular Aortic Repair — Abdominal Transcend. Zenith ENDOVASCULAR GRAFTS

Abrir o catálogo na página 1
Endovascular Aortic Repair - Abdominal - 3

Transcend. Going beyond. That’s what it means to Transcend. That’s the essence of Zenith

Abrir o catálogo na página 3
Endovascular Aortic Repair - Abdominal - 4

Active Fixation Our anchoring barbs are the industry standard for design and migration resistance. Radial Force Self-expanding z-stents provide radial force, added stability and optimal graft-to-vessel apposition. Columnar Strength Long main-body design features a time-tested balance of length, stability and flexibility. ARC Technology™ — Demand systemic migration resistance. The three features that make up ARC Technology — active fixation, radial force, columnar strength — work in unison to give all Zenith® AAA endovascular grafts unrivaled migration resistance. That includes 0% migration...

Abrir o catálogo na página 4
Endovascular Aortic Repair - Abdominal - 5

Endovascular Aortic Repair — Abdominal Zenith Spiral-Z™ AAA Iliac Leg Graft ENDOVASCULAR GRAFT

Abrir o catálogo na página 5
Endovascular Aortic Repair - Abdominal - 7

Zenith Flex AAA Endovascular Graft Transcend. Zenith Flex was built to offer you precision, from delivery with the Z-Trak® Introduction System to the unrivaled migration resistance provided by ARC Technology™. Flex is a combination of our most innovative advances and time-tested features that results in giving you proven Zenith performance. Precision Delivery Precision Design Z-Trak Introduction System Precisely deliver, position and deploy Zenith Flex with the Z-Trak Introduction System. • Flexor® Introducer Sheath - Facilitates precise delivery and placement with kink-resistant technology...

Abrir o catálogo na página 7
Endovascular Aortic Repair - Abdominal - 8

Zenith Flex AAA - Graft Specifications Bifurcated Main Body Grafts Note: Ipsilateral and contralateral limb diameters on all 22 mm diameter main body grafts are 11 mm. Note: Black numbers on stents indicate stent lengths in millimeters (mm). Red numbers indicate fabric gap lengths in millimeters (mm). Fabric gaps may vary. Z-Trak® Introduction System for Main Body Grafts 22-26 mm grafts: 18 Fr (6.0 mm) ID/7.1 mm OD 28-32 mm grafts: 20 Fr (6.7 mm) ID/7.7 mm OD 36 mm grafts: 22 Fr (7.3 mm) ID/8.5 mm OD 11 cm

Abrir o catálogo na página 8
Endovascular Aortic Repair - Abdominal - 9

Zenith Flex AAA - Component Ordering Information Order Number Reference Part Number Main Body Diameter mm Main Body Length mm Introducer Sheath ID/OD Fr (mm)/mm 22 mm Diameter Main Body Diameter Main Body Length 36 mm Diameter G48432 Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

Abrir o catálogo na página 9
Endovascular Aortic Repair - Abdominal - 10

Zenith Flex AAA - Graft Specifications Ancillary Components Main Body Extensions Note: Black numbers on stents indicate stent lengths in millimeters (mm). Z-Trak® Introduction System for Main Body Extensions 22-26 mm grafts: 18 Fr (6.0 mm) ID/7.1 mm OD 28-36 mm grafts: 20 Fr (6.7 mm) ID/7.7 mm OD 11 cm Z-Trak® Introduction System for Converters 24 mm grafts: 18 Fr (6.0 mm) ID/7.1 mm OD 28-36 mm grafts: 20 Fr (6.7 mm) ID/7.7 mm OD Z-Trak® Introduction System for Iliac Plugs 14-16 mm grafts: 14 Fr (4.7 mm) ID/5.4 mm OD 20-24 mm grafts: 16 Fr (5.3 mm) ID/6.0 mm OD Z-Trak® Introduction System...

Abrir o catálogo na página 10
Endovascular Aortic Repair - Abdominal - 11

Zenith Flex AAA - Component Ordering Information Proximal Diameter Order Number Reference Part Number Introducer Sheath ID/OD Fr (mm)/mm Order Number Distal Diameter Reference Part Number Introducer Sheath ID/OD Fr (mm)/mm Main Body Extensions G55204 Introducer Sheath ID/OD Fr (mm)/mm Order Number Reference Part Number Main Body Extensions G55211 Length Reference Part Number Introducer Sheath ID/OD Fr (mm)/mm Reference Part Number Introducer Sheath ID/OD Fr (mm)/mm Order Number Iliac Plugs Length Proximal Diameter Order Number Iliac Leg Extension G55195 Some products or part numbers may not...

Abrir o catálogo na página 11
Endovascular Aortic Repair - Abdominal - 13

Zenith Spiral-Z AAA Iliac Leg Graft Transcend. Introducing the Zenith® Spiral-Z™ AAA Iliac Leg Graft. It’s designed specifically to give you enhanced graft flexibility, ease of delivery and proximal sealing-site radial force.1 Your patients will also have more treatment options with a variety of Spiral-Z iliac leg sizes and diameters available. Spiral-Z exemplifies our ongoing commitment to providing you and your patients with quality products from the continual development of the Zenith Flex® AAA Endovascular Graft platform. Precision Design Precision Delivery Flexibility Treat even the...

Abrir o catálogo na página 13
Endovascular Aortic Repair - Abdominal - 14

Zenith® Spiral-Z™ AAA Iliac - Graft Specifications Contralateral/Ipsilateral Iliac Leg Grafts 9 mm 13 mm Note: Black numbers on stents indicate stent lengths in millimeters (mm). Z-Trak® Introduction System for Iliac Legs 9–16 mm grafts: 14 Fr (4.7 mm) ID/5.4 mm OD 20–24 mm grafts: 16 Fr (5.3 mm) ID/6.0 mm OD 11 cm

Abrir o catálogo na página 14
Endovascular Aortic Repair - Abdominal - 15

Zenith® Spiral-Z™ AAA Iliac - Component Ordering Information Order Number Reference Part Number Distal Iliac Leg Diameter mm Working Length of Iliac Leg mm Introducer Sheath ID/OD Fr (mm)/mm Working Length of Contralateral Iliac Leg 20 mm Diameter Working Length of Ipsilateral Iliac Leg G55241 Distal Iliac Leg Diameter 24 mm Diameter G55244 Distal Iliac Leg Diameter Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

Abrir o catálogo na página 15
Endovascular Aortic Repair - Abdominal - 17

Zenith Renu AAA Ancillary Graft Transcend. Zenith Renu was specifically designed for secondary interventions in patients with previously implanted EVAR devices that have migrated. You and your patients are presented with an alternative to device explantation, because Zenith Renu is available in either extension or conversion configurations. Precision Design Precision Delivery Migration Resistance Reduce the risk of migration and enhance graft-tovessel apposition with suprarenal active fixation. Zenith Renu features stainless steel anchoring barbs positioned incrementally on the suprarenal...

Abrir o catálogo na página 17
Endovascular Aortic Repair - Abdominal - 18

Zenith Renu AAA Ancillary - Graft Specifications Note: Black numbers on stents indicate stent lengths in millimeters (mm). Red numbers indicate fabric gap lengths in millimeters (mm). Fabric gaps may vary. Z-Trak® Introduction System 22-26 mm grafts: 18 Fr (6.0 mm) ID/7.1 mm OD 28-32 mm grafts: 20 Fr (6.7 mm) ID/7.7 mm OD 36 mm grafts: 22 Fr (7.3 mm) ID/8.5 mm OD 11 cm

Abrir o catálogo na página 18

Todos os catálogos e folhetos técnicos COOK Medical

  1. LITHO-60

    16 Páginas

  2. Litho 100

    16 Páginas

  3. Physician’s

    92 Páginas

  4. HiWire

    2 Páginas

  5. EUS 3 Needle

    12 Páginas

  6. Surgical Melker

    2 Páginas

  7. Beacon Tip

    4 Páginas

  8. Royal Flush Plus

    4 Páginas

  9. Fusion ® Zilver

    2 Páginas

  10. FISTULA BRUSH

    2 Páginas

  11. Fusion ®

    2 Páginas

  12. Zenith

    2 Páginas

  13. EchoTip®

    2 Páginas

  14. Hercules ®

    2 Páginas

  15. Biodesign®

    2 Páginas

Catálogos arquivados

  1. Hemostasis Family

    6 Páginas