Phase 3 - 1

D ef i b r i l l at o r / Tr an s c u t a n e o us P a c e r An a l yz e r specifically designed to test Pulsed Multiphasic defibrillators. Versatility – Phase 3 tests Monophasic, Biphasic and Pulsed Multiphasic Defibrillators, AEDs and Transcutaneous Pacers with better than 1% accuracy on either line or battery power. Portability – Detachable Paddle Plate provides easy hands-free testing. Battery provides up to 24 hours of continuous operation. USB Connectivity – USB Communication capability allows real-time waveform capture and efficient data transfer to your PC. Real-Time Wave Capture – Capture high-resolution signal data to a PC running Phase3pc software immediately after discharge. Test Record Storage – Phase 3 provides storage for up to 50 Test Records and up to 10 defibrillator discharge waveforms as Wave Records. Variable Load Module – Our optional, exclusive VLM allows testing defibrillators at maximum energy with selectable loads from 25 to 175 ohms, in accordance with AAMI DF-80 and IEC 60601-2-4. High-resolution wave graphics and test data are obtained with Phase 3VL software — a standard accessory to the VLM. Phase 3pc Companion Software – Included as a standard accessory, Phase 3pc allows you to create and edit autosequences, download and store test data and wave graphics to your PC. Variable Load Module Accur acy M att er s • www.datr end.com Phase 3 is the first Defibrillator / Pacer Analyzer

Abrir o catálogo na página 1
Phase 3 - 2

Phase 3 – Performance Specifications Tests Performed Defibrillator Energy, Charge Time and Cardioversion Automated External Defibrillator (AED) Performance ECG Monitor Performance Pacer Sensitivity, Refractory Periods and Noise Immunity Pacer Pulse Characteristics Energy Measurement, General Load resistance: 50 ohms ±1%, non-inductive ECG amplitude at defib pads: 1 mV QRS WAVEFORM (oscilloscope) Output High Range: 1000:1 amplitude attenuation Low Range: 200:1 amplitude attenuation Waveform Playback: 200: 1 time base expansion First Phase Pulse Width: 0.1 - 58 msec Second Phase Pulse Width...

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos Datrend Systems

  1. vPad-O2

    106 Páginas

  2. venTest

    2 Páginas

  3. vPad-BP

    1 Páginas

  4. vPad-Mini

    2 Páginas

  5. vPad-ES2

    2 Páginas

  6. vPad-Rugged2

    2 Páginas

  7. Infutest Solo

    2 Páginas

  8. vPad-RF

    2 Páginas

  9. vPad-A1

    2 Páginas

  10. vPad-IN

    2 Páginas

  11. Model 20A

    1 Páginas

  12. FMS-3

    2 Páginas

  13. AMPS-1

    2 Páginas

  14. Oxitest Plus7

    2 Páginas

  15. Phase 3 VLM

    2 Páginas