Excertos do catálogo

Operative Technique Renewing Innovations. Enduring Solutions.
Abrir o catálogo na página 1
INTRODUCTION Like the art of fine woodworking, the Novation® Comprehensive Hip System design began with the end in mind. Before launching into development, Exactech’s engineers and design team surgeons established a comprehensive plan. Their goal: to provide a system of femoral stems, acetabular components and surgical instrumentation that would address any situation encountered during primary total hip replacement. They let science be their guide and conducted an extensive research review to identify the best of the best in design and materials. These proven features were blended with...
Abrir o catálogo na página 2
PRE-OPERATIVE PLANNING Tools choice is approximately at the center of rotation of the templated acetabulum. Note: Most of the time the chosen prosthetic head (neck length) does not line up with the center of rotation of the acetabulum or even with a mark in the center of the femoral head.The appropriate lateral offset, either Standard or Extended, can be recorded at this time. The head usually is positioned proximal and medial to the center of rotation of the acetabulum. In effect, at the end of the operation the surgeon will be pulling on the limb and lifting the prosthetic femoral head...
Abrir o catálogo na página 3
OPERATIVE TECHNIQUE OVERVIEW Osteotomy Guide Placement Opening of the Proximal Femur with Box Osteotome Entry into Femoral Canal Calcar Preparation (Optional) Trial Component Insertion 2
Abrir o catálogo na página 4
Broach Assembly/ Disassembly Broach Insertion Femoral Stem Insertion Femoral Head Impaction 3
Abrir o catálogo na página 5
Detailed OPERATIVE TECHNIQUE Approach and Exposure The Novation femoral stems are compatible with any standard surgical exposure. In this operative technique, the posterior lateral approach is described. Dislocation and Osteotomy A. Hip Dislocation The hip should be dislocated by flexion, adduction and internal rotation. Placing a bone hook around the femoral neck may help in difficult cases. Soft tissues along the intertrochanteric line to the proximal border of the lesser trochanter should be cleared. When tight, the gluteus maximus tendon may be released to improve exposure. The limb...
Abrir o catálogo na página 6
B. Broach Assembly/Disassembly The Element Broach Handle is assembled to the Element Broach by pulling back the trigger while inserting the rectangular body of the Element Broach Handle into the superior aspect of the Broach and releasing the lever (Figure 4). Care should be taken to ensure that the assembly of the instruments is correct. C. Femoral Broaching Broaching is performed with progressive broach sizes, beginning with the smallest Broach. The Broach is inserted into the femoral canal in a few degrees of anteversion (Figure 5). The surgeon should alternate impaction and withdrawal...
Abrir o catálogo na página 7
D. Calcar Preparation (Optional) Calcar planing can be performed, if desired, in order to remove any bone that protrudes above the level of the impacted Element Broach by guiding the Calcar Planar Assembly into the hole on the interior surface of the broach attachment opening (Figure 6). Calcar Planar Blade Replacement - If necessary, a Replacement Calcar Planar Blade can be used to ensure proper removal of excess bone. Use the Calcar Planar Blade Removal Tool to remove the used blade, replace it with a new blade and tighten with the Removal Tool. Trial Reduction A. Trial Component...
Abrir o catálogo na página 8
Final Reduction A. Femoral Stem Insertion Figure 8 Femoral Stem Insertion The appropriate femoral stem is chosen and assembled to the Offset Stem Inserter. The femoral stem is impacted taking care to ensure correct rotational alignment, version and depth (Figure 8). It may be necessary to allow the bone to adapt to the implant as it is being impacted. Another trial reduction can be performed with the final femoral stem and Femoral Head Trial. B. Femoral Head Impaction The taper of the femoral stem should be clean and dry. The selected femoral head component is placed onto the taper of the...
Abrir o catálogo na página 9
System Specifications and implant ordering information Lateral Offset Element Stem Details Size (mm) Standard Lateral Offset with following head lengths (mm) Extended Lateral Offset with following head lengths (mm) Stem Length Note: For each change in head length, vertical leg length changes approximately 2.5mm. Femoral Head Ordering Information Size (mm) 8 * Stem length is measured from medial resection level ** Skirted heads
Abrir o catálogo na página 10
Femoral Stem Ordering Information Size (mm) Collarless Standard Offset Collared Extended Offset Standard Offset
Abrir o catálogo na página 11
INSTRUMENT LISTING Catalog Number Part Description 165-31-00 Novation Element Core Instrument Case 109-00-00 Universal Femoral Stem Extractor 113-03-04 T-Handle Starter Reamer 12/14 Femoral Head Impactor
Abrir o catálogo na página 12
Catalog Number Part Description 161-00-06 Slap Hammer Adapter 161 -00-07 Replacement Calcar Planar Blade 161 -00-24 Calcar Planar Assembly 161 -00-25 Calcar Planar Blade Removal Tool 165-00-05 Novation Element Osteotomy Guide
Abrir o catálogo na página 13
Catalog Number Part Description Novation Element Femoral Broach/Trial Instrument Case 22mm Femoral Head Trial, 12/14, +0mm 22mm Femoral Head Trial, 12/14, +3.5mm 22mm Femoral Head Trial, 12/14, +7mm 22mm Femoral Head Trial, 12/14, +10mm 28mm Femoral Head Trial, 12/14, O-Ring, -3.5mm 28mm Femoral Head Trial, 12/14, O-Ring, +0mm 28mm Femoral Head Trial, 12/14, O-Ring, +3.5mm 28mm Femoral Head Trial, 12/14, O-Ring, +7mm 28mm Femoral Head Trial, 12/14, O-Ring, +10mm 32mm Femoral Head Trial, 12/14, O-Ring, -3.5mm 32mm Femoral Head Trial, 12/14, O-Ring, +0mm 32mm Femoral Head Trial, 12/14,...
Abrir o catálogo na página 14
Catalog Number Part Description Element Broach Handle Element Broach, Size 8 Element Broach, Size 9 Element Broach, Size 10 Element Broach, Size 11 Element Broach, Size 12 Element Broach, Size 13 Element Broach, Size 14 Element Broach, Size 15 Element Broach, Size 16 Element Broach, Size 17 Element Broach, Size 18 Element Standard Offset Neck Trial, Size 8-10 Element Standard Offset Neck Trial, Size 11-13 Element Standard Offset Neck Trial, Size 14-18 Element Extended Offset Neck Trial, Size 8-10 Element Extended Offset Neck Trial, Size 11-13 Element Extended Offset Neck Trial, Size 14-18...
Abrir o catálogo na página 15Todos os catálogos e folhetos técnicos Exactech
-
A New Perspective in Total Ankle
2 Páginas
-
AcuMatch
7 Páginas
-
Hip Family Brochure
9 Páginas
-
Corporate Product Brochure
5 Páginas
-
Anterior Approach Patient Education
12 Páginas
-
Biologics
9 Páginas
-
Corporate brochure
11 Páginas
-
Cemex_Main_
12 Páginas
-
LBS II
12 Páginas
-
Calcium Phosphate Cement
5 Páginas
-
EXACTECH HIP
8 Páginas
-
Bipolar/Unipolar Heads
2 Páginas
-
Primary Femoral Solutions Alteon
2 Páginas
-
Novation
16 Páginas
-
Equinoxe Fx Plate
2 Páginas
-
Equinoxe Product
2 Páginas
-
Equinoxe Reverse
8 Páginas
-
Equinoxe System
7 Páginas
-
Novation CFS
2 Páginas
-
AcuMatch_Family
20 Páginas
-
knee replacement
5 Páginas
-
Spacer
4 Páginas
-
accelerate
3 Páginas
-
EXACTECH HIP Design Rationale
12 Páginas
-
ALTEON™ Tapered Wedge Femoral Stem
2 Páginas
-
EXACTECH HIP Operative Technique
16 Páginas
-
ALTEON™ Neck Preserving Femoral Stem
2 Páginas