Excertos do catálogo

I u m i Ayc.es: Dental ^ y LUMIX C.P.S. Dental is an innovative high power multidiodic Laser with C.P.S.® emission (continuous, pulsed and superpulsed) that performs effective photobiostimulation in the dental field. The triple wavelength (650nm - 810nm - 910nm) of the LUMIX® C.P.S.® Dental and the high peak power (100W) ensure especially deep tissue penetration. fisioline biomedical Instrumentation 3 WAVELENGTHS 650nm The emitted energy is almost totally absorbed by hemoglobin, so it is particularly recommended as coagulant and antiedemigen. At this wavelength, skin melanin optimally...
Abrir o catálogo na página 2
THERAPEUTIC indications THERAPEUTIC indications AESTHETIC MEDICINE By acting on the fibroblasts, LUMIX® C.P.S.® Dental generates a physiological production of collagen and hyaluronic acid and improves the skin tone. In specific facial treatment, it stimulates microcirculation and oxygenating processes on skin, facilitating and enhancing the activity of anti-aging formulations. In a non-thermal, non-ablative manner, LUMIX® C.P.S.® Dental triggers a sequence of different biochemical effects that promote the synthesis of neo-collagen and elastin by the fibroblasts of the dermis. This process...
Abrir o catálogo na página 3
2011 Colour touch-screen display with simple, intuitive interface Influence of Superpulsed Laser Therapy on Healing Processes Following Tooth Extraction. PHOTOMEDICINE AND LASER SURGERY 2011; Volume X, N. X, Pp. 1–7 Marco Mozzati, D.D.S., Germana Martinasso, Ph.D., Nadia Cocero, D.D.S., Renato Pol, D.D.S., Marina Maggiora, Ph.D., Giuliana Muzio, Ph.D., and Rosa Angela Canuto, M.D. University of Turin, Turin, Italy. 2010 Audio-video application tutorials Preset therapeutic protocols Handpiece with interchangeable optics Autoclavable fiber terminal Therapeutic terminal with spacers USB port...
Abrir o catálogo na página 4
U ITI I^cps: Dental • Model: LUMIX® C.P.S.® Dental Version • Technical classification: electromedical equipment - Class I type BF • Commercial classification: device for laser therapy • Medical device class: IIb (Dir. 93/42/EEC, as amended by Directive 2007/47/EC) • Applicable regulations: General standard IEC EN 60601-1; specific standard IEC EN 60601-2-22; collateral standard IEC EN 60601-1-6. • Weight: 3.5Kg • Dimensions: 210x300x160mm • Power supply voltage: 100-240V single phase (external power supply) • Network frequency: 50-60Hz • Laser source: Class 4 • Operating mode: continuous,...
Abrir o catálogo na página 5Todos os catálogos e folhetos técnicos Fisioline
-
LUMIX SURGERY DUAL DENTAL
9 Páginas
-
LUMIX® SURGERY VETERINARY
5 Páginas
-
Lumix® C.P.S.® Veterinary
7 Páginas
-
Lumix Surgery Dual Veterinary
9 Páginas
-
LUMIX SURGERY DUAL
7 Páginas
-
LUMIX® Q PLATFORM
9 Páginas
-
LINFOPRESS STUDIO
3 Páginas
-
FISIOFIELD MINI
2 Páginas
-
MODULO_MODULO PLUS
3 Páginas
-
LUMIX 100 250
7 Páginas
-
Aesthetic medicine
9 Páginas
-
Fisiosonic Plus
3 Páginas
-
Fisiosonic
3 Páginas
-
FISIOFIELD MIDDLE
3 Páginas
-
FISIOFIELD MAXI
3 Páginas
-
INSTRUMENTAL PHYSICAL THERAPY
11 Páginas
-
Lumix-Q
7 Páginas
-
O.P.A.F.® Therapy
5 Páginas
-
LUMIX CW
7 Páginas
-
LUMIX® 2
5 Páginas
-
Lumix® C.P.S.®
7 Páginas
-
O.P.A.F.® Therapy Veterinary
5 Páginas
-
Lumix C.P.S. Podiatry
7 Páginas
-
Lumix® PLUS, Lumix® ULTRA
7 Páginas
-
Lumix® PLUS HP, Lumix® ULTRA HP
7 Páginas
-
MODULO PLUS PRO version
5 Páginas
-
FISIOWAVE
3 Páginas
-
Winner
12 Páginas
-
FISIOLINE RADIANT VETERINARY
5 Páginas
-
Fisioline Radiant
7 Páginas
-
LINFOPRESS MASTER IT-EN
2 Páginas
-
Fisiosonic® Veterinary
2 Páginas
-
Lumix® Surgery
8 Páginas
-
Lumix Surgery Dental
8 Páginas
-
Fisiofield Middle Veterinary
2 Páginas