Excertos do catálogo

Implants trauma Cannulated Tibia Nail
Abrir o catálogo na página 1
1. introduction P. 5 Preface P. 6 Screw P. 6 Properties P. 7 Pre-operative measurement of nail Length P. 8 Indications & Contraindications 2. Surgical Technique P. 10 Pre-operative patient planning P. 10 Incision P. 11 Assembly of the insertion guide P. 12 Locating entry portal P. 12 Nailing P. 13 Proximal Locking P. 14 Measuring of proximal screw length P. 15 Distal Locking P. 16 Measuring of distal screw length P. 17 Removal of the insertion guide P. 17 Endcap insertion P. 19 Postoperative treatment P. 19 Nail removal 3. Information P. 21 Dotize® P. 22 Order list P. 26 Reconditioning Manual
Abrir o catálogo na página 3
Preface The newly developed CTN - Cannulated Tibia Nail enables the surgical treatment of various fractures of the tibia. Stable, ridged fixation of fractures can be achieved, with the advantage of early weight bearing due to intramedullary insertion.
Abrir o catálogo na página 5
Spiral Drill, D=4.2mm, L=350mm, AO Connector Spiral Drill, Angledrived, D=4.2mm, L=140mm Shank, PRS, Solid, WS 3.5, L=230mm, AO Connector Properties Properties of the material: • Nail material: TiAl6V4 ELI • Material of screw: TiAl6V4 ELI • Easier removal of the implant if necessary • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy • Anatomically shaped • Radiolucent insertion guide • Intramedullary insertion allows early weight bearing • Multi-direction proximal Locking • Dynamic interlock options to allow for fracture...
Abrir o catálogo na página 6
1. Determine the nail length with the template (see right) and a X-Ray Pre-operative measurement of nail length Scale 1.6:1 2. Determine the nail length with the X-Ray ruler (59205). 3. Insert the calibrated D=3.0mm guide wire with ball tip (35301-800) or the D=2.5mm guide wire (35251-800) and read off the required nail length at the calibrated guide wire.
Abrir o catálogo na página 7
Indications: ♦ Proximal, metaphyseal, diaphyseal and distal metaphyseal fractures ♦ Simple, segmental and comminuted fractures • Open fractures of the tibia ♦ Surgical correction of non-unions, mal-unions and delayed unions ♦ Pathological fractures ♦ Fractures involving osteopenic and osteoporotic bone Contraindications: ♦ Active infection near the fracture site ♦ Skeletally immature patients ♦ Severe osteoporosis or inadequate bone stock ♦ Skin and soft tissue problems ♦ Foreign body (material) sensitivity ♦ Obesity ♦ Lack of patient compliance
Abrir o catálogo na página 8
Surgical Technique
Abrir o catálogo na página 9
Pre-operative patient planning • Surgical planning depends on the operative technique individually preferred. • In most cases, the patient should be placed supine on a standard radiolucent operating room table. Incision Entry point depends surgeon‘s preference: • • • • Suprapatellar (green line) Medial to the patellar ligament Through the patellar ligament Lateral to the patell
Abrir o catálogo na página 10
Assembly of the insertion guide fastening with the flatwrench, WS 20 (70020) fastening with the socket wrench, WS 10, L=250mm (561002-250) To attach the jig to the handle, rotate the spinning fastener clockwise. Turn it until it stops and move it into the provided slots (highlighted in yellow). Advice: To verify the correct assembly of the insertion guide, insert a tissue protection sleeve and a drill sleeve into a guide hole in the jig. Then push the drill through the drill sleeve in the appropriate nail interlock hole.
Abrir o catálogo na página 11
• The entry portal for the insertion of a tibiaL nail is very important. • The individual anatomy should be carefully evaluated. • The insertion point should be in line with the medullary canal on the AP fluoroscopy view (just medial to the lateral tibial eminence) and just on the anterior roll over of the tibia plateau on the lateral fluoroscopy view. • Open the medullary canal with the required drill, awl or gimlet to the desired diameter. • Introduce the D=3.0mm guide wire with ball tip (35301-800) when using the optional available reamer down to the level of the fracture, reduce the...
Abrir o catálogo na página 12
Proximal Locking • For the proximal Locking the jig is attached to the handle with the spinning fastener (see page 11). • The circular holes on the handle provide static locking with rotational and axial stability. • Dynamic locking can be carried out with a sleeve (1180087) inserted in the oblong hole and provides rotation stability with axial compression on weight bearing. Static Locking: eccentric hole distal Dynamic Locking: eccentric hole proximal • Insert the trochar (118008-8) through the D=4.3mm drill sleeve (118008-6) and advance to the cortex through a stab incision. • Remove the...
Abrir o catálogo na página 13
Measuring of proximal screw length Drilling of the screw holes under fluoroscopy can be done. Once the far cortex is drilled the length can be read off the calibrated D=4.2mm spiral drill (61423-350).
Abrir o catálogo na página 14
Distal Locking • Distal locking is carried out using fluoroscopy and perfect circle technique. • Before locking, the correct reduction should be verified. • The spiral drill, angledrived, D=4.2mm, L=140mm, AO Connector (61427-140), is used to drill through the near and far cortex. • Measure the screw length. • Insert a D=4.7mm cortical screw (32475-XX) of appropriate length determined previously. • Verify the correct screw position under fluoroscopy. Attention: Do not overtighten the sc
Abrir o catálogo na página 15
Measuring of distal screw length The distal screw length may also be determined using the standard depth gauge from the solid small fragment screws set (59022).
Abrir o catálogo na página 16
Removal of the insertion guide For disassembly of the insertion guide (118008) release the fastening screw (118008-4) with the socket wrench, WS 10, L=250mm (561002-250) and remove it. Endcap insertion Finally screw the endcap with the screwdriver shank, PRS, solid, WS 3.5mm, L=230mm, AO Connector (54353-230SH) into the proximal end of the nail, which will protect the internal thread of the tibia nail against tissue growth, thus facilitating removal of the implant at a later date.
Abrir o catálogo na página 17Todos os catálogos e folhetos técnicos I.T.S.
-
ufs
1 Páginas
-
DHL
2 Páginas
-
ITS
2 Páginas
-
DHL - Distal Humeral Locking Plates
20 Páginas
-
PHL
24 Páginas
-
ACLS
20 Páginas
-
CFN
32 Páginas
-
OLS
24 Páginas
-
PHLs
20 Páginas
-
UOL - Ulna Osteotomy Locking Plate
32 Páginas
-
SR Sacral Rods
20 Páginas
-
HCS
24 Páginas
-
TOS Twist-Off Screw
20 Páginas
-
TLS
20 Páginas
-
PRS-RX
32 Páginas
-
HLS
20 Páginas
-
PLS - Pilon Locking Plates System
24 Páginas
-
ES
20 Páginas
-
SR
20 Páginas
-
FL
24 Páginas
-
PL - Pilon Locking Plate small
12 Páginas
-
PRS - Pelvic Reconstruction System
28 Páginas
-
PRL - PROlock Radius Locking Plate
20 Páginas
-
OHL - Olecranon Hook Locking Plate
24 Páginas
-
OL - Olecranon Locking Plate
24 Páginas
-
PHL - Proximal Humeral Locking Plate
28 Páginas
-
CAS
40 Páginas
-
FCN
20 Páginas
-
HOL
24 Páginas
-
FLS
24 Páginas
-
PFL
20 Páginas
-
DTL
24 Páginas
-
HTO
24 Páginas
-
PTL
32 Páginas
-
DFL
32 Páginas
-
SCL
32 Páginas
-
SLS
24 Páginas
-
CAL
20 Páginas
-
DUL
24 Páginas
-
CLS
28 Páginas