Excertos do catálogo

r\ M I DISTAL HUMERAL LOCKING PLATES I I L emergency team for broken bones®
Abrir o catálogo na página 1
Medial Plate Dorsolateral Plate DISTAL HUMERAL PLATES emergency team for broken bones® 37351-XX-N Cortical Screw, locking, D=3.5mm, SH 61273-100 Spiral Drill, D=2.7mm, L=100mm, AO Connector 56252 Screwdriver, WS 2.5, self-holding sleeve 32351-XX Cortical Screw, D=3.5mm 61273-100 Spiral Drill, D=2.7mm, L=100mm, AO Connector 56252 Screwdriver, WS 2.5, self-holding sleeve 37422-XX-N Cancellous Screw, locking, D=4.2mm, SH 61253-180 Spiral Drill, D=2.5mm, L=180mm, AO Connector 56252 Screwdriver, WS 2.5, self-holding sleeve 35164-150 Guide Wire, Steel, D=1.6mm, L=150mm, TR, with Thrd. 02 i.t.s.
Abrir o catálogo na página 2
Features Features Implant: Material: • ultidirectional Locking M • ree choice of screw angle F • eft and right version L • natomically contoured A • 4.2 mm locking Cancellous Ø Screw • 3.5 mm Cortical Screw Ø • 3.5 mm locking Cortical Screw Ø • late material: Titanium P • aterial of screws: TiAL6V4 ELI M • asier removal of implant after fracture has E healed • mproved fatigue strength of implant I • educed risk of cold bonding R • educed risk of inflammation and allergy R locking DISTAL HUMERAL PLATES All I.T.S. locking plates are anatomically pre-contoured. In the unlikely event that the...
Abrir o catálogo na página 3
Indications Contraindications • Supra- & diacondylar upper-arm fractures • evere osteoporosis S • Existing infections in the area of the fracture • trongly reduced general S condition. DISTAL HUMERAL PLATES emergency team for broken bones® Time of operation Approach Implantation • Within the first hours of the trauma or in the following days. • If the operation is not primary, arm should be immobilised in a splint. Median incision in the ulnar rim on the distal upper arm above the olecranon. Exposure and retraction of the ulnar nerve. Depending on the type of fracture, olecranonosteotomy...
Abrir o catálogo na página 4
Postoperative treatment • n case of stable repair of I fracture, dressing and movement therapy. • n case of poor bone quality or I insecure fixation, movement fixator for a maximum of 6 weeks or upper-arm plaster cast for a maximum of 3 weeks. • To prevent heterotopic ossification, Indometazin (Indozid) 50 mg 2 x daily for 2 weeks. locking DISTAL HUMERAL PLATES i.t.s. 05
Abrir o catálogo na página 5
DISTAL HUMERAL PLATES emergency team for broken bones® Order No. New Humeral Plate, Distal, 4-Hole, Left, Dorsolateral 21242-4 New Humeral Plate, Distal, 4-Hole, Right, Dorsolateral 21241-4 1 Humeral Plate, Distal, 5-Hole, Left, Dorsolateral 21242-5 2 Humeral Plate, Distal, 5-Hole, Right, Dorsolateral 21241-5 New Humeral Plate, Distal, 6-Hole, Left, Dorsolateral 21242-6 New Humeral Plate, Distal, 6-Hole, Right, Dorsolateral 21241-6 New Humeral Plate, Distal, 7-Hole, Left, Dorsolateral 21242-7 New Humeral Plate, Distal, 7-Hole, Right, Dorsolateral 21241-7 3 Humeral Plate, Distal, 8-Hole,...
Abrir o catálogo na página 6
DISTAL HUMERAL PLATES emergency team for broken bones® Cortical Screw, D=3.5mm, L=24mm Cortical Screw, D=3.5mm, L=26mm 32351-26 Cortical Screw, D=3.5mm, L=28mm 32351-28 Cortical Screw, D=3.5mm, L=30mm 32351-30 Cortical Screw, D=3.5mm, L=32mm 32351-32 Cortical Screw, D=3.5mm, L=34mm 32351-34 Cortical Screw, D=3.5mm, L=36mm 32351-36 Cortical Screw, D=3.5mm, L=38mm 32351-38 Cortical Screw, D=3.5mm, L=40mm 7 32351-24 32351-40 37422-14-N Cancellous Screw, Locking, D=4.2mm, L=16mm, SH 37422-16-N Cancellous Screw, Locking, D=4.2mm, L=18mm, SH 37422-18-N Cancellous Screw, Locking, D=4.2mm, L=20mm,...
Abrir o catálogo na página 8
DISTAL HUMERAL PLATES emergency team for broken bones® Cancellous Screw, Locking, D=4.2mm, L=48mm, SH 37422-48-N Cancellous Screw, Locking, D=4.2mm, L=50mm, SH 37422-50-N Cancellous Screw, Locking, D=4.2mm, L=55mm, SH 37422-55-N Cancellous Screw, Locking, D=4.2mm, L=60mm, SH 37422-60-N 8 56252 9 Depth Gauge , Solid Small Fragment Screws 59022 10 Cortical Counter Sink, with Stop Support 63404 11 Spiral Drill, D=2.5mm, L=180mm, AO-Connector 61253-180 12 Spiral Drill, D=2.7mm, L=100mm, AO-Connector 61273-100 13 Drill Guide, D=2.0/2.7mm 14 Guide Wire, Steel, D=1.6mm, L=150mm, TR, w. Gew 15...
Abrir o catálogo na página 10
LOCKING Locking works because of: • Screw material (TiAlV) is slightly harder than plate material (Titanium Grade 2) • Screw head forms thread into the plate (no cutting) Benefits: • • • • • ± 15° and Locking No pre threading No cold welding No debris Re-setting of screw (up to 3 times) 30° ® DOTIZE Chemical process - anodization in a strong alkaline solution * Type III anodization Dotize Type II anodization Layer thickness 60-200nm Layer thickness 2000-10 000nm + Different colors + Film become an interstitial part of the titanium - Implant surface remains sensitive to: Chipping Peeling...
Abrir o catálogo na página 12
Sterilization Guidelines The following remarks should serve as a guideline in the sterilization of medical products. IMPORTANT INDICATIONS FOR DOCTORS AND OPERATING THEATRE PERSONNEL This instruction leaflet refers to all supplied nonsterile implants and all reusable instruments from I.T.S. GmbH. Detailed information for the identification of the product (such as system classification, cat. no.) can be found in the product identification code and/ or on the package label. Make sure that you are familiar with the possibilities of application, combinability and correct handling of the...
Abrir o catálogo na página 14
Sterilization Guidelines Disinfection Equipment: Commercially available disinfectants authorized for use with medical products e.g.. MEDICLEAN FORTE) can be used (but only according to the instructions of the disinfectant producer). In the case of automatic cleaning, a final rinse cycle at 90 °C for 5 minutes can be finally carried out to provide thermal disinfection. Drying Drying as part of the cleaning/ disinfection cycle should not exceed 110 °C. Checking, Maintenance and Inspection • Each instrument or implant is to be inspected carefully to make sure that all visible dirt has been...
Abrir o catálogo na página 15Todos os catálogos e folhetos técnicos I.T.S.
-
ufs
1 Páginas
-
DHL
2 Páginas
-
ITS
2 Páginas
-
DHL - Distal Humeral Locking Plates
20 Páginas
-
PHL
24 Páginas
-
ACLS
20 Páginas
-
CFN
32 Páginas
-
OLS
24 Páginas
-
PHLs
20 Páginas
-
CTN - Cannulated Tibia Nail
28 Páginas
-
UOL - Ulna Osteotomy Locking Plate
32 Páginas
-
SR Sacral Rods
20 Páginas
-
HCS
24 Páginas
-
TOS Twist-Off Screw
20 Páginas
-
TLS
20 Páginas
-
PRS-RX
32 Páginas
-
HLS
20 Páginas
-
PLS - Pilon Locking Plates System
24 Páginas
-
ES
20 Páginas
-
SR
20 Páginas
-
FL
24 Páginas
-
PL - Pilon Locking Plate small
12 Páginas
-
PRS - Pelvic Reconstruction System
28 Páginas
-
PRL - PROlock Radius Locking Plate
20 Páginas
-
OHL - Olecranon Hook Locking Plate
24 Páginas
-
OL - Olecranon Locking Plate
24 Páginas
-
PHL - Proximal Humeral Locking Plate
28 Páginas
-
CAS
40 Páginas
-
FCN
20 Páginas
-
HOL
24 Páginas
-
FLS
24 Páginas
-
PFL
20 Páginas
-
DTL
24 Páginas
-
HTO
24 Páginas
-
PTL
32 Páginas
-
DFL
32 Páginas
-
SCL
32 Páginas
-
SLS
24 Páginas
-
CAL
20 Páginas
-
DUL
24 Páginas
-
CLS
28 Páginas