Implants trauma Ulna Osteotomy Locking Plate
Abrir o catálogo na página 1
All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or bent several times. This is particularly important in the case of titanium implants, to prevent material fatigue and subsequent failure. The method of bending is the conscious responsibility of the operating doctor;...
Abrir o catálogo na página 2
1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 8 Indications & Contraindications 2. Surgical Technique P. 10 Assembling of the instruments P. 11 Pre-operative patient preparation P. 11 Exposure P. 12 Plate insertion P. 13 Placement of the tension bolts P. 15 Shortening P. 18 Reduction P. 20 Placement of the screws P. 22 Removal of the instruments P. 24 Postoperative treatment P. 24 Explantation P. 24 Summary 3. Information P. 25 Notes P. 27 Locking P. 27 Dotize® P. 28 Order list P. 30 Reconditioning Manual
Abrir o catálogo na página 3
Preface The Ulna Osteotomy Locking Plate provides a plate system (hybrid system) to be fixated with locking screws and compression screws, which is specially adapted to the anatomic and biomechanic requirements after a shortening osteotomy of the distal ulna. In a single device, the Ulna Osteotomy Locking Plate allows for a unique coplanar orientation of the incision with rotation-stable shortening and the option for compression. The standardization of multiple surgical procedures into a single device system improves the quality of the surgical procedure.
Abrir o catálogo na página 5
o Screws Cortical Screw, Locking, D=3.0mm Spiral Drill, D=2.4mm, L=I00mm, AO Connector Screwdriver, Torque, T9x70 Self-holding sleeve, Screwdriver, Torque 9 Cortical Screw, D=2.7mm Spiral Drill, D=2.0mm, L=I00mm, AO Connector Screwdriver, Torque, T9x70 Self-holding sleeve, Screwdriver, Torque 9 Cancellous Screw, locking, D=3.0mm Spiral Drill, D=2.0mm, L=I00mm, AO Connector Screwdriver, Torque, T9x70 Self-holding sleeve, Screwdriver, Torque 9
Abrir o catálogo na página 6
o Properties Properties of the material: ♦ Plate material: Titanium ♦ Material of screws: TiAl6V4 ELI ♦ Easier removal of the implant after the fracture has healed ♦ Improved fatigue strength of the implant ♦ Reduced risk of cold welding ♦ Reduced risk of inflammation and allergy Properties of the implant: ♦ Multi-directional Locking ♦ Anatomically shaped ♦ Plate length: 5-hole ♦ No dislocation of the parts of the bone due to fixation using longhole ♦ Positioning of the plate prior to the osteotomy ♦ Compression instrument for simple joining of the osteotomy surfaces (selective compression...
Abrir o catálogo na página 7
Indications: ♦ Impaction syndrome of the ulnar wrist ♦ Symptomatic, post-traumatic ulnar malpositon in the distal radio-ulnar joint (DRUJ) ♦ Degenerative ulnar wrist ♦ Correction of the ulnar position relative to the unaffected other side up to a maximum of 6mm in one step or 13mm in two steps (see figure page 19) Extended Indications: ♦ Primary ulnar shortening in forearm fractures with insufficient reconstruction of the length of the radius ♦ Deformities ♦ Degenerative ulnar variant in conically shaped DRUJ according to Forstner Contraindications: ♦ Severe osteoporosis ♦ Existing bone or...
Abrir o catálogo na página 8
Surgical Technique
Abrir o catálogo na página 9
Part for left version Part of right version
Abrir o catálogo na página 10
Pre-operative patient preparation Place the patient in a supine position, cover the arm to be freely mobile and place it on an X-ray transparent table at a shoulder abduction of 90°. Perform the operation under regional or general anaesthesia with or without using a tourniquet on the upper arm. The shape of the implant allows for palmar, ulnar or dorsal positioning of the plate. The plate should be completely fitted to the bone without protruding. As the the distal palmar section of the ulna is usually curved, more proximal positioning of the plate or pre-bending of the implant are...
Abrir o catálogo na página 11
Plate insertion After opening the forearm fascia, mobilize bluntly the belly of the FCU (M. flexor carpi ulnaris) at its insertion point at the ulna and retract it medial using Hohmann retractors. Define the optimal position of the plate and incise the dorsal forearm fascia in the designated osteotomy area.
Abrir o catálogo na página 12
Placement of the tension bolts Place the assembled osteotomy system jig upon the ulna osteotomy plate, which is attached to the ulna using the plate holes alternating from the outside centrer; distally with D=3.0mm locking cancellous screws (37302-XX) or D=3.0mm locking cortical screws (37301-XX) (spiral drill, D=2.0mm, L=100mm, AO Connector (61203-100) for locking cancellous screw / spiral drill, D=2.4mm, L=100mm, AO Connector (61243-100) for locking cortical screw), proximally with 2 tension bolts (680859) after inserting the drill guide, D=2.0mm (62208) for the tension bolt and a D=2.0mm...
Abrir o catálogo na página 13
Shortening Incise the periosteum at the osteotomy site and minimally retract it before starting. Using the transection gauge and producing as little heat as possible, make two atraumatic, parallel cuts according to the measured shortening. The maximum recommended osteotomy length is 6mm. Caution: In osteoporotic bones, traction bolts may tilt due to high traction forces (malformation of drilled holes in osteoporotic bone). The thickness of the saw blade is a maximum of 0.7mm. We recommend a saw blade 0.5 – 0.7mm in thickness, to achieve a precise cut.
Abrir o catálogo na página 15
Reduction After removal of the dissection, the osteotomy surfaces must be cleaned meticulously of bone or soft tissue remnants. After loosening the tension bolts (1/2 to 3/4 turn), shortening is performed using the set screw. If there are excessive tensions and shortening difficulties, this is usually the consequence of bone or soft tissue remnants. After contact of the osteotomy surfaces, prior to a desired compression, the reduction may additionally be secured using holding forceps. Finally, tighten the tension bolts firmly.
Abrir o catálogo na página 18Todos os catálogos e folhetos técnicos I.T.S.
-
ufs
1 Páginas
-
DHL
2 Páginas
-
ITS
2 Páginas
-
DHL - Distal Humeral Locking Plates
20 Páginas
-
PHL
24 Páginas
-
ACLS
20 Páginas
-
CFN
32 Páginas
-
OLS
24 Páginas
-
PHLs
20 Páginas
-
CTN - Cannulated Tibia Nail
28 Páginas
-
SR Sacral Rods
20 Páginas
-
HCS
24 Páginas
-
TOS Twist-Off Screw
20 Páginas
-
TLS
20 Páginas
-
PRS-RX
32 Páginas
-
HLS
20 Páginas
-
PLS - Pilon Locking Plates System
24 Páginas
-
ES
20 Páginas
-
SR
20 Páginas
-
FL
24 Páginas
-
PL - Pilon Locking Plate small
12 Páginas
-
PRS - Pelvic Reconstruction System
28 Páginas
-
PRL - PROlock Radius Locking Plate
20 Páginas
-
OHL - Olecranon Hook Locking Plate
24 Páginas
-
OL - Olecranon Locking Plate
24 Páginas
-
PHL - Proximal Humeral Locking Plate
28 Páginas
-
CAS
40 Páginas
-
FCN
20 Páginas
-
HOL
24 Páginas
-
FLS
24 Páginas
-
PFL
20 Páginas
-
DTL
24 Páginas
-
HTO
24 Páginas
-
PTL
32 Páginas
-
DFL
32 Páginas
-
SCL
32 Páginas
-
SLS
24 Páginas
-
CAL
20 Páginas
-
DUL
24 Páginas
-
CLS
28 Páginas