

Excertos do catálogo

These CO2 incubators set advanced standards in performance and freedom from contamination. The two research models have the added benefit of a high temperature decontamination facility. Advanced Microprocessor Control The specially developed microprocessor controller gives the user day to day control over all alarm settings, alarm delay and calibration adjustment. These settings are protected by an anti-tampering procedure. Sensors placed within key areas of the chamber constantly monitor and enable the control system to optimise temperature and C02 levels. After door opening, the culture conditions quickly recover without overshoot, and stable control is maintained. Profiled heating, a technique developed by LEEC, eliminates all risk of “hot-spots”. Active Contamination Control All models have a unidirectional airflow in the work area, an in-line HEPA filter and an ultra smooth stainless steel chamber with rounded edges. The indirectly heated inner glass door remains condensation free. These features all help to reduce the risk of contamination. The Research models also have a high temperature decontamination facility operated by a security keyswitch. User experience has shown high temperature to be especially effective in eliminating culture contamination. In-Vivo Simulation The advanced LEEC-20.2 microprocessor combined with the ducted airflow system ensures that temperature and CO2 stabilities (typically +0.1 °C and ±0.2%) are maintained to the tightest tolerances in order to give optimum “in-vivo” simulation. Standard Features Control • Microprocessor control with soft touch panel. • Bright LED digital displays for temperature and CO2. • Comprehensive alarm system (audible and visual) monitors all critical functions. Stainless steel outer cabinet for longer life. Ultra smooth stainless steel chamber helps contamination control. Adjustable levelling feet. Two cable access ports. • Built-in cooling coil can be connected to a source of chilled water for operation close to or below ambient temperature. • High and low alarm warnings (temperature and CO2). • Independent overtemperature safety cutout with failsafe. • Remote alarm connections (volt-free, N/0, N/C). Contamination Control • • • • Unidirectional airflow. HEPA filter removes airborne contaminants. High temperature decontamination (Research models). Indirectly heated in
Abrir o catálogo na página 1
Cell Culture Incubators ta(1) to +60°C <±0.1°at+37°C <±0.2° at +37°C Typically < 6 minutes LEEC semiconductor ta(1) to +60°C <±0.1°at+37°C <±0.2° at +37°C Typically < 6 minutes LEEC semiconductor Range Control Recovery Sensor 0 to 20% <±0.2% at 5% Typically 3 minutes LEEC tc 0 to 20% <±0.2% at 5% Typically 3 minutes LEEC tc 0 to 20% ±0.2% at 5% Typically 7 minutes LEEC tc 02 Range Control Recovery Sensor Oto21% ±0.1% at 5% Typically 7 minutes Maintenance free fuel cell Temperature Range Control Variation Recovery Sensor Construction Alarms FYR Fyrite C02 test kit (0 - 20%). FYR/02 Fyrite 02...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos LEEC
-
Post Mortem Table
2 Páginas
-
Cremator Charger
4 Páginas
-
PST 65
2 Páginas
-
P33
1 Páginas
-
TOUCH T190, T190S
12 Páginas
-
Self Contained Recirculating Coolers
1 Páginas
-
embalming station
1 Páginas
-
Lightweight Stretchers
1 Páginas
-
Coffin Bier
1 Páginas
-
Stretcher Covers
1 Páginas
-
Combination Stretchers
1 Páginas
-
First Call One Man Loader
1 Páginas
-
Multilevel Removal Trolley
1 Páginas
-
Hydraulic Stacking Trolley
2 Páginas
-
Mobile Instrument Trolley
2 Páginas
-
Low Loading Trolley
2 Páginas
-
Refrigerated Body Storage
1 Páginas
-
Mortuary Trays
1 Páginas
-
Body Identification System
2 Páginas
-
LEEC RCS
2 Páginas
-
Autopsy solid top Pedestal
1 Páginas
-
Dissecting trolley
2 Páginas
-
Ventilated Specimen Stores
6 Páginas
-
Ultrasonic Humidity Cabinets
2 Páginas
-
LEEC Precision Incubator
1 Páginas
-
LEEC Bespoke Funeral Director Range
16 Páginas
-
Viewing Trolley
1 Páginas
-
LEEC Autopsy tables brochure
1 Páginas
-
downdraft dissecting bench brochure
1 Páginas
-
Formalin Mixing Unit brochure
1 Páginas
-
Autopsy Docking Station brochure
1 Páginas
-
Foetal Storage
1 Páginas
-
Hydraulic Stacking Trollet
2 Páginas
-
Hydraulic Embalming Trolley
2 Páginas
-
Mobile Racking
1 Páginas
-
Body Storage Trays
1 Páginas
-
Lift Assist brouchure.
2 Páginas
-
Refrigerated End Loading Cabinet
2 Páginas
-
LEEC Easy Fit Cool Zone
2 Páginas
-
refrigerated side loading cabinet
1 Páginas
-
Warming Cabinets
2 Páginas
-
Drying Cabinet
2 Páginas
-
Precision Cooled Incubator brochure
1 Páginas
-
Classic Incubator brochure
2 Páginas
-
Culture Safe Precision range brochure
12 Páginas
Catálogos arquivados
-
LEEC 65st CREMATOR CHARGER XL
2 Páginas