video corpo

Leica AOBS
1 / 16Páginas

Excertos do catálogo

Leica AOBS - 1

AOBS – The Most Versatile Beam Splitter ® Acousto-Optical Beam Splitter for the TCS SP8 Confocal • High transparency and narrow excitation bands increase cell viability and reduce photobleaching. • The freely programmable AOBS perfectly adapts to challenging multicolor experiments, new laser lines, and the tunable White Light Laser of the TCS SP8 X. • Provides fast line sequential imaging of living cells having spectrally close uorophores.

Abrir o catálogo na página 1
Leica AOBS - 2

Discover the AOBS® – Changing Confocal Imaging Fluorescence imaging is performed in an incident light configuration: the excitation light enters the specimen on the same side from which the emission is collected. This setup requires a device that separates excitation and emission light: a beam splitter. The AOBS is a uniquely flexible, efficient, and fast beam splitting device. FLEXIBILITY AND VERSATILITY SIMPLIFY GAIN MORE LIGHT WITH MAXIMUM FAST, RELIABLE SWITCHING MULTICOLOR IMAGING The position of the band for excitation The reflection bands for excitation Reprogramming the AOBS is a...

Abrir o catálogo na página 2
Leica AOBS - 3

Transmission Curves for Different Beam Splitting Devices 488 nm Fig. 1a: Dichroic. Non-flexible reflections on bands. Fig. 1b: AOBS. All wavelength are fully flexible, adjusting to your experiment. Comparing the transmission curves of a typical triple dichroic mirror (blue) and AOBS (red) for excitation with 488, 561, and 633 nm shows two major advantages of the AOBS: • The AOBS reection bands have steep edges and narrow bandwidth – allowing the collection of more emission light. • The AOBS is more exible and can accomodate up to eight reection bands – facilitating the simultaneous imaging...

Abrir o catálogo na página 3
Leica AOBS - 4

A Comparison of Beam Splitting Methods Classically, beam splitting is done by dichroic mirrors that reflect certain color bands and transmit between them. The reflecting part is used for excitation; the emission is collected through the transmitting band. An AOBS also separates excitation and emission light, but works in a completely different way as compared to a dichroic mirror. It is an active, programmable device that is uniquely flexible, efficient, and fast. SPLITTING MIRRORS HAVE FIXED AOBS: A SINGLE, FLEXIBLE, AND RELIABLE OPTICAL ELEMENT For different applications, the dichroic...

Abrir o catálogo na página 4
Leica AOBS - 5

Acousto-Optical Beam Splitting Technology in Detail Beam splitting by the AOBS is based The grid constant is variable and depends crystal. These crystals are fully transparent applied wave, which makes it easily from below 400 nm to more than 4 μm. Applying a mechanical wave at radio- If excitation light of the desired color frequency results in periodic density enters the crystal at an appropriate variations within the crystal. The crystal angle, the light will be acousto-optically density affects the refractive index. refracted and will merge with the Thus, the acoustic wave creates a...

Abrir o catálogo na página 5
Leica AOBS - 6

plasma membrane early endosomes

Abrir o catálogo na página 6
Leica AOBS - 7

A Versatile Beam Splitter for all Confocal Imaging Applications The AOBS is ideal for both single parameter fluorescence and sophisticated multichannel imaging – without changing dichroic mirrors. Upon selecting a set of colors for excitation, the AOBS will automatically be programmed to direct these lines onto the specimen and transmit the emission between them. No need to think about which mirror to use. The TCS SP8 with AOBS is perfect for core imaging facilities, where so many different fluorochromes need to be imaged each day. It largely reduces the training time needed for novice...

Abrir o catálogo na página 7
Leica AOBS - 9

Live Cell Imaging with Spectrally Close Fluorophores With dichroic beam splitters, fluorophores with a large spectral separation between excitation peaks must be selected for multiple staining of biological specimens. Otherwise, there is insufficient space for emission collection. Additionally, multichroic mirrors do not allow for closely adjacent excitation lines. This limitation is removed with the AOBS. CHOOSE SIMULTANEOUS OR FAST SWITCHING FOR LIVE CELL FAST SPECTRAL SEPARATION OF GFP SEQUENTIAL MODE The AOBS offers excitation with laser The AOBS offers sufficiently short The efficiency...

Abrir o catálogo na página 9
Leica AOBS - 10

Detect Fluorescence and Reflection Simultaneously The AOBS can easily convert to a 50/50 splitter for a desired wavelength for optimal reflected light contrast. Simultaneously, other laser lines can still be used for fluorescence excitation and corresponding emission. FREELY COMBINE FLUORESCENCE FAST SWITCHING BETWEEN REFLECTION STUDY OF CANCER CELL INVASION WITH REFLECTION The AOBS is not just a programmable Any excitation color can be employed for An interesting application example for chromatic splitter. It can be used as a reflected light. And you may even wish combining reflection and...

Abrir o catálogo na página 10
Leica AOBS - 11

Fig. 7: NIH3T3 fibroblasts. Actin Alexa 488, Ex 488 nm, Em 500-550 nm (green). Reflection of focal contacts, Ill 476 nm Det 467-492 nm (gray). Paxilin Cy3, Ex 561 nm, Em 570-627 nm (red). Image courtesy of M. Bastmeyer, KIT Karlsruhe, Germany. Fig. 8: Arabidopsis thaliana, root tissue. PINI-GFP (membrane, green), REV-2xYFP (nucleus, red), reflection (gray). Image courtesy of M. Heisler, EMBL Heidelberg, Germany.

Abrir o catálogo na página 11
Leica AOBS - 12

Background Information: White Light With supercontinuum fiber lasers, a light source is available that covers a wide spectral range and fulfills the requirements for confocal microscopy. A truly white source emits photons in a spectral range, e.g. visible light, without gaps. Light composed of three laser lines, e.g. red, yellow, and blue, is perceived by the human eye as “white” as well, but is far from covering a spectral range without gaps. Such devices should not be called “white sources”.

Abrir o catálogo na página 12
Leica AOBS - 13

A Freely Tunable Beam Splitter for the White Light Laser The White Light Laser (WLL) used in the TCS SP8 X combines a white light source that covers the spectral range from 470 nm to 670 nm and an acousto-optical tunable device for the selection of single lines. Up to eight lines can be selected from the spectrum, each line being freely tunable in both color and intensity. TUNABLE EXCITATION REQUIRES FREELY FAST AND EASY AUTOMATIC SETUP OF TRUE SPECTRAL DETECTION WITH TUNABLE BEAM SPLITTING The WLL provides any color combination The continuously tunable illumination within the visible...

Abrir o catálogo na página 13

Todos os catálogos e folhetos técnicos Leica Microsystems

  1. M844 F40/F20

    16 Páginas

  2. EnFocus

    12 Páginas

  3. M822 F40 / F20

    12 Páginas

  4. M320 for ENT

    12 Páginas

  5. ARveo 8

    16 Páginas

  6. Emspira 3

    4 Páginas

  7. Exalta

    2 Páginas

  8. FLEXACAM C1

    4 Páginas

  9. EM KMR3

    8 Páginas

  10. EM UC7

    16 Páginas

  11. EM TRIM2

    8 Páginas

  12. EM RAPID

    8 Páginas

  13. EM ICE

    12 Páginas

  14. EM TXP

    10 Páginas

  15. EM RES102

    12 Páginas

  16. EM TIC 3X

    16 Páginas

  17. TL4000 BFDF

    16 Páginas

  18. F12 I floor stand

    6 Páginas

  19. XL Stand

    4 Páginas

  20. KL300 LED

    8 Páginas

  21. LED1000

    16 Páginas

  22. LED3000 BLI

    20 Páginas

  23. LED5000 NVI

    20 Páginas

  24. LED3000 NVI

    20 Páginas

  25. LED3000 DI

    20 Páginas

  26. LED5000 HDI

    20 Páginas

  27. LED5000 CXI

    20 Páginas

  28. LED2500

    8 Páginas

  29. LED5000 MCI

    20 Páginas

  30. LED3000 MCI

    20 Páginas

  31. LED5000 SLI

    20 Páginas

  32. LED3000 SLI

    20 Páginas

  33. LED2000

    8 Páginas

  34. LED5000 RL

    20 Páginas

  35. LED3000 RL

    20 Páginas

  36. MZ10 F

    4 Páginas

  37. M165 FC

    16 Páginas

  38. M205 FCA, M205 FA

    16 Páginas

  39. A60 F, A60 S

    16 Páginas

  40. M50, M60, M80

    12 Páginas

  41. DVM6

    16 Páginas

  42. HCS A

    20 Páginas

  43. TCS SPE

    20 Páginas

  44. DFC450 C

    6 Páginas

  45. DFC295

    6 Páginas

  46. MC170 HD

    6 Páginas

  47. DFC3000 G

    6 Páginas

  48. DMC4500

    4 Páginas

  49. ICC50 W, ICC50 E

    6 Páginas

  50. DFC9000

    2 Páginas

  51. IC90 E

    6 Páginas

  52. DMC6200

    8 Páginas

  53. DMC5400

    8 Páginas

  54. SFL7000

    4 Páginas

  55. EL6000

    4 Páginas

  56. SFL100

    4 Páginas

  57. SFL4000

    4 Páginas

  58. DMi8 S Platform

    2 Páginas

  59. DMi8 M / C / A

    12 Páginas

  60. DM IL LED

    12 Páginas

  61. DMi1

    6 Páginas

  62. DM3 XL

    7 Páginas

  63. FS M

    4 Páginas

  64. FS C

    4 Páginas

  65. FS CB

    4 Páginas

  66. DM3000, DM3000 LED

    16 Páginas

  67. DM750 M

    12 Páginas

  68. DM750

    12 Páginas

  69. DM500

    12 Páginas

  70. DM300

    8 Páginas

  71. DM12000 M

    8 Páginas

  72. DM8000 M

    8 Páginas

  73. DM1750 M

    12 Páginas

  74. DM4 M, DM6 M

    12 Páginas

  75. DM2000, DM2000 LED

    16 Páginas

  76. DM1000

    16 Páginas

  77. DCM8

    16 Páginas

  78. DM1000 LED

    16 Páginas

  79. DM2500

    16 Páginas

  80. DM4 B & DM6 B

    16 Páginas

  81. DM6 M LIBS

    2 Páginas

  82. S9 Series

    12 Páginas

  83. Z6 APO

    16 Páginas

  84. Z16 APO

    16 Páginas

  85. M620 F20

    8 Páginas

  86. M220 F12

    8 Páginas

  87. Proveo 8

    16 Páginas

  88. M525 F20

    12 Páginas

  89. PROvido

    8 Páginas

  90. Leica M530 OHX

    16 Páginas

  91. Leica DMC2900

    6 Páginas

  92. Leica DMshare

    2 Páginas

  93. Leica_SL801-Flyer

    2 Páginas

  94. DM2700 M

    12 Páginas