video corpo

Leica TCS SP8 STED 3X
1 / 24Páginas

Excertos do catálogo

Leica TCS SP8 STED 3X - 1

A Decade of Super-Resolution Innovation Working with passion for the global research community: The TCS SP8 STED 3X marks one decade of innovative super-resolution technology by Leica Microsystems - providing quality data and efficient processes foryour science. Dual color for TCS SP8 STED TCS SP8 TCS STED (CW) and gated STED STED 3X LASER RADIATION VISIBLE AND INVISIBLE - CLASS 3B AVOID DIRECT EXPOSURE TO BEAM LASER RADIATION VISIBLE AND INVISIBLE - CLASS 4 AVOID EYE OB SKIN EXPOSURE TO DIRECT OR SCAITEBED RAOIATION Order no.: English 1593003011 ■ Copyright © by Leica Microsystems CMS GmbH, Mannheim, Germany, 2014 Subject to modifications. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH

Abrir o catálogo na página 1
Leica TCS SP8 STED 3X - 2

Your Next Dimension

Abrir o catálogo na página 2
Leica TCS SP8 STED 3X - 4

Welcome To Your Next Dimension! The new TCS SP8 STED 3X opens up new dimensions for your research: Discover the possibilities of super-resolution in real 3D.

Abrir o catálogo na página 4
Leica TCS SP8 STED 3X - 6

Pure Physics, More Efficiency The new TCS SP8 STED 3X strengthens your science: ››Tunable and direct super-resolution in x, y and z reveal smallest details ›› Multiple STED lines open up the full spectrum of visible light ›› Gated detection improves resolution and increases live cell capabilities ›› STED WHITE objective has optimal color correction for the full spectrum ›› Auto beam alignment provides stability and reliability ›› Modular concept based on the TCS SP8 allows you to upgrade at any time ›› Smart STED Wizard intuitively controls your experiments ›› Huygens deconvolution gets...

Abrir o catálogo na página 6
Leica TCS SP8 STED 3X - 8

TCS SP8 STED 3X – Here’s Your Next Dimension! Here’s Your Next Dimension! STED microscopy by Leica Microsystems has revolutionized the study of subcellular a ­ rchitecture and cell dynamics at the nanoscale. The fully integrated STED (STimulated Emission Depletion) system meets the requirements of daily research and provides fast, intuitive, and purely optical access to structural details far beyond the diffraction limit. Gated STED substantially improves resolution to below 50 nm and increases live cell viability. Now, the next generation of STED, the TCS SP8 STED 3X, broadens the scope of...

Abrir o catálogo na página 8
Leica TCS SP8 STED 3X - 9

Pure Physics, More Reliability STimulated Emission Depletion imaging reaches lateral resolution below 50 nm in true optical sections by downscaling the spot from where fluorescence is generated. STED is pure physics: What you see is what you get. The principle Super-resolution – fast and direct The basic principle of STED, which was A phase mask filter determines the area STED technology provides fast and direct first described by Stefan Hell in 1994 , is in the focus plane where STED light is access to structural details at the nano- simple. The effective focal spot scanning dominant, e.g....

Abrir o catálogo na página 9
Leica TCS SP8 STED 3X - 10

TCS SP8 STED 3X – Pure Physics, More Reliability STED Intensity Achieved resolution (left) correlates with STED laser power (right). Right panel: STED donut with area of stimulated emission in red, area of fluorescence in green. Resolution improvement achieved by STED microscopy is purely optical and does not rely on mathematics. Of course, you can further process your images with deconvolution. STED allows you to directly compare the outcome with the raw data and makes your results more reliable. Don’t waste time with artifacts! Key Publications ›› Hell, S. W. & Wichmann, J. Breaking the...

Abrir o catálogo na página 10
Leica TCS SP8 STED 3X - 11

Life Happens in 3D – Now Observe its Detail Immunofluorescence stain of Golgi marker in HeLa cells: Surface rendered 3D reconstruction after Huygens deconvolution of a z stack (20 planes), 3D donut 100%. STED data (green) show a clear resolution increase compared to the confocal result (red). Data courtesy of Dr. Timo Zimmermann, Center for Genomic Regulation, Barcelona, Spain.

Abrir o catálogo na página 11
Leica TCS SP8 STED 3X - 12

xy view xz view Histone H3-Alexa 568 in HeLa cells: The highest lateral resolution increase is achieved by the vortex donut, maximal resolution increase in x, y and z by 3D STED. Note the loss of structures of objects that are not in the super-resolved focus plane when using 3D STED. 3D STED also achieves an increase of resolution in the xy dimension. Confocal x axis z axis XZ axis plot of Histone H3-Alexa 568 in HeLa cells. 0% z donut allocates all STED light to the vortex donut resulting in maximal resolution increase in x and y, but not in z compared to confocal microscopy. A small focal...

Abrir o catálogo na página 12
Leica TCS SP8 STED 3X - 13

Push the Boundaries! Organisms, tissues and cells are three dimensional. To investigate cellular processes you want to consider all directions. The new TCS SP8 STED 3X allows you to extend the boundaries of super-resolution in all dimensions. Discover more details in X, Y and Z Engineer your PSF to your science With TCS SP8 STED 3X, two STED light paths generate TCS SP8 STED 3X gives you the possibility to match the different STED patterns (see figure below). For best resolution resolution of your microscope in all dimensions to your scientific in x and y the light is allocated to the STED...

Abrir o catálogo na página 13
Leica TCS SP8 STED 3X - 14

Immunostaining of endosomal marker (Lamp M) in TCS SP8 STED 3X – Subchapter 13 HeLa cells. Note the loss of structures out of superresolved focal plane (white arrows) in the middle compared to confocal images. Courtesy of Shem Johnson, University of Geneva, Switzerland. gSTED with maximum z resolution Push the limits even further The powerful Huygens STED deconvolution package, exclusively supplied with every TCS SP8 STED 3X system, helps to improve your data. Huygens decreases noise levels dramatically and also enhances resolution in x, y and z. After deconvolution of STED data, even...

Abrir o catálogo na página 14
Leica TCS SP8 STED 3X - 15

See the Full Spectrum of Life Seeing subcellular structures in nanoscopic detail opens a new world to scientists. Multicolor applications give access to detailed information about the interrelationships of various structures. The new STED 3X module offers multiple STED laser lines at different wavelengths in one instrument. Super-resolved colocalization studies have never been so easy. Tunable spectral super-resolution – the freedom to choose Super-resolution and standard labeling strategies are not mutually exclusive. A broad variety of popular dyes and fluorescent proteins in the green...

Abrir o catálogo na página 15

Todos os catálogos e folhetos técnicos Leica Microsystems

  1. M844 F40/F20

    16 Páginas

  2. EnFocus

    12 Páginas

  3. M822 F40 / F20

    12 Páginas

  4. M320 for ENT

    12 Páginas

  5. ARveo 8

    16 Páginas

  6. Emspira 3

    4 Páginas

  7. Exalta

    2 Páginas

  8. FLEXACAM C1

    4 Páginas

  9. EM KMR3

    8 Páginas

  10. EM UC7

    16 Páginas

  11. EM TRIM2

    8 Páginas

  12. EM RAPID

    8 Páginas

  13. EM ICE

    12 Páginas

  14. EM TXP

    10 Páginas

  15. EM RES102

    12 Páginas

  16. EM TIC 3X

    16 Páginas

  17. TL4000 BFDF

    16 Páginas

  18. F12 I floor stand

    6 Páginas

  19. XL Stand

    4 Páginas

  20. KL300 LED

    8 Páginas

  21. LED1000

    16 Páginas

  22. LED3000 BLI

    20 Páginas

  23. LED5000 NVI

    20 Páginas

  24. LED3000 NVI

    20 Páginas

  25. LED3000 DI

    20 Páginas

  26. LED5000 HDI

    20 Páginas

  27. LED5000 CXI

    20 Páginas

  28. LED2500

    8 Páginas

  29. LED5000 MCI

    20 Páginas

  30. LED3000 MCI

    20 Páginas

  31. LED5000 SLI

    20 Páginas

  32. LED3000 SLI

    20 Páginas

  33. LED2000

    8 Páginas

  34. LED5000 RL

    20 Páginas

  35. LED3000 RL

    20 Páginas

  36. MZ10 F

    4 Páginas

  37. M165 FC

    16 Páginas

  38. M205 FCA, M205 FA

    16 Páginas

  39. A60 F, A60 S

    16 Páginas

  40. M50, M60, M80

    12 Páginas

  41. DVM6

    16 Páginas

  42. HCS A

    20 Páginas

  43. TCS SPE

    20 Páginas

  44. DFC450 C

    6 Páginas

  45. DFC295

    6 Páginas

  46. MC170 HD

    6 Páginas

  47. DFC3000 G

    6 Páginas

  48. DMC4500

    4 Páginas

  49. ICC50 W, ICC50 E

    6 Páginas

  50. DFC9000

    2 Páginas

  51. IC90 E

    6 Páginas

  52. DMC6200

    8 Páginas

  53. DMC5400

    8 Páginas

  54. SFL7000

    4 Páginas

  55. EL6000

    4 Páginas

  56. SFL100

    4 Páginas

  57. SFL4000

    4 Páginas

  58. DMi8 S Platform

    2 Páginas

  59. DMi8 M / C / A

    12 Páginas

  60. DM IL LED

    12 Páginas

  61. DMi1

    6 Páginas

  62. DM3 XL

    7 Páginas

  63. FS M

    4 Páginas

  64. FS C

    4 Páginas

  65. FS CB

    4 Páginas

  66. DM3000, DM3000 LED

    16 Páginas

  67. DM750 M

    12 Páginas

  68. DM750

    12 Páginas

  69. DM500

    12 Páginas

  70. DM300

    8 Páginas

  71. DM12000 M

    8 Páginas

  72. DM8000 M

    8 Páginas

  73. DM1750 M

    12 Páginas

  74. DM4 M, DM6 M

    12 Páginas

  75. DM2000, DM2000 LED

    16 Páginas

  76. DM1000

    16 Páginas

  77. DCM8

    16 Páginas

  78. DM1000 LED

    16 Páginas

  79. DM2500

    16 Páginas

  80. DM4 B & DM6 B

    16 Páginas

  81. DM6 M LIBS

    2 Páginas

  82. S9 Series

    12 Páginas

  83. Z6 APO

    16 Páginas

  84. Z16 APO

    16 Páginas

  85. M620 F20

    8 Páginas

  86. M220 F12

    8 Páginas

  87. Proveo 8

    16 Páginas

  88. M525 F20

    12 Páginas

  89. PROvido

    8 Páginas

  90. Leica M530 OHX

    16 Páginas

  91. Leica AOBS

    16 Páginas

  92. Leica DMC2900

    6 Páginas

  93. Leica DMshare

    2 Páginas

  94. Leica_SL801-Flyer

    2 Páginas

  95. DM2700 M

    12 Páginas