lifesensevet sensors.qxp veterinary pulse oximetry Veterinary Sensors and Their Placement This document does not replace NONIN’s Operator’s Manual. The Operator’s Manual must be read, with special attention to the “Warnings”, “Cautions”, and “Contraindications” section before using a NONIN veterinary pulse oximeter. When monitoring oxygen saturation (SpO2), the sensor site must meet the following criteria: Sensor site must be well perfused. Sensor site must allow light to be transmitted through the tissue. (Skin must not be overly pigmented and fur/feathers etc. may need to be removed.) Sensor site must allow proper attachment of the sensor. (Note: Certain veterinary drugs may cause reduced perfusion to the sensor site. This could compromise the function of a pulse oximeter.) Lingual Sensor (Model 2000SL) This sensor can be placed on the right side, left side, or the end of the tongue. Wait approximately 10 to 15 seconds for an adequate pulse signal. If you are unable to obtain an SpO2 reading, move the sensor to another site on the tongue and wait 10 to 15 seconds until an adequate pulse signal is displayed. It is a good idea to secure the cables so the weight of the cable doesn’t move the sensor. If you still have difficulty getting an SpO2 reading, examine the tongue to see if it is quivering. This could be a reaction to certain medications. If the tongue continues to quiver, choose a different sensor site. » The vulva or prepuce* If the animal is large enough, it has been reported by some veterinarians that the prepuce or vulva might be an alternate site for the lingual clip sensor. Remember that this site must be well perfused and not pigmented. » Achilles tendon* On light colored animals (a color of gray or lighter), an alternate application site may be the Achilles tendon. Remove the hair and make sure the skin is not pigmented. Transflectance Sensor (Model 2000T) The transflectance sensor requires more technique to use than the lingual sensor. Tips for using the transflectance sensor are: If you wrap this sensor too tightly, you may impede perfusion to the sensor site. Wrap this sensor so that it is “snug”. If the sensor is wrapped too loosely, it may move and display erroneous readings. The most common site for this sensor is at the base of the tail close to the anus. Be sure there is no hair at this site and that the skin is not pigmented. *Possible sensor sites as reported by veterinary professionals.
Abrir o catálogo na página 1
lifesensevet sensors.qxp veterinary pulse oximetry Another site to consider is a pink paw pad*. Be sure the pink area of the pad will cover the front and back diodes on the sensor. Don’t wrap it too tightly. Wait 10 to 15 seconds for an adequate pulse signal. If the transflectance sensor is used between the toes*, in the webbed area, make sure to remove any dark hair and position the sensor up against the webbing. Wrap the whole foot with enough pressure to hold the sensor in place, but not enough to impede perfusion. An optional site is the metatarsal*. There is a spot immediately behind...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos Nonin
-
Unmatched Pulse Oximetry
1 Páginas
-
Multiple Parameters. One Solution.
2 Páginas
-
NoninConnect Elite 3240
4 Páginas
-
8204CA
4 Páginas
-
8000 series
2 Páginas
-
6000 C series
2 Páginas
-
Nonin Onyx Finger Puise Oximeters
6 Páginas
Catálogos arquivados
-
SenSmart® 8006 Hybrid Sensor
2 Páginas
-
WristOx2 ® Model 3150 USB
2 Páginas
-
Narcotrend Compact-M
2 Páginas
-
9840/8500 Series
1 Páginas
-
Onyx III 9591
2 Páginas
-
USB-Desaturation
1 Páginas
-
Capnography-for-CPR.
2 Páginas
-
Nonin3230-3231
4 Páginas
-
PalmSAT 2500 Brochure
2 Páginas
-
Capnography Pain Management
2 Páginas
-
CapnographyEMSTransport
2 Páginas
-
incorporating capnography monitoring
2 Páginas
-
RespSense
2 Páginas
-
Why Nonin Sensors
4 Páginas
-
PureSAT Advantage
2 Páginas
-
Product Catalog
21 Páginas
-
Avant 2120
2 Páginas
-
Model 7500 Series
2 Páginas
-
PureLight Sensors Brochure
2 Páginas
-
3150 Sleep Flyer
2 Páginas
-
Obstructive Sleep Apnea (OSA)
4 Páginas
-
LifeSense VET Brochure
2 Páginas
-
SenSmart Universal Oximetry System Adult
14 Páginas
-
Nonin Onyx Brochure
6 Páginas
-
LifeSense®
2 Páginas
-
9840 Series
2 Páginas
-
WristOx 3100 Brochure
2 Páginas
-
ipod Specifications
6 Páginas
-
WIDESCREEN Pulse Oximeter
2 Páginas
-
Vet Family Brochure
4 Páginas
-
System Story Brochure
2 Páginas
-
OEM Xpod Brochure
2 Páginas
-
Avant® 9600
2 Páginas
-
Onyx II, Model 9560 Brochure
3 Páginas
-
SenSmart 8100 Soft SpO2 Sensor
2 Páginas
-
Avant® 9700
2 Páginas
-
Model 8500 Series
2 Páginas
-
Capnography Use in Homecare
2 Páginas
-
Capnography Use in Sleep Labs
2 Páginas
-
EQUANOX?, Model 7600
2 Páginas
-
Flexi-Form ® III 7000 Series
2 Páginas
-
Cloth 6000C Series
2 Páginas
-
Onyx Vantage 9590
2 Páginas
-
Dr Petty GO2 Brochure
13 Páginas
-
System Story Brochure Old
4 Páginas
-
nVision
4 Páginas
-
2500A VET Spec Sheet
2 Páginas
-
PulseSense VET Brochure
2 Páginas
-
RespSense VET Brochure
2 Páginas
-
9847V Brochure
2 Páginas
-
Vet Family Brochure Old
4 Páginas
-
Model 8500AV Brochure
2 Páginas
-
3150 Ambulatory Flyer
2 Páginas
-
LifeSense® Old
2 Páginas
-
LifeSense®
2 Páginas
-
WristOx2?
2 Páginas
-
Model 7500
4 Páginas
-
PulseSense? WIDESCREEN OXYMETRY
2 Páginas
-
Avant® 9600
1 Páginas
-
SpO2 Disposable Sensors
4 Páginas
-
9500 Spec Sheet
2 Páginas
-
Onyx® II 9550
2 Páginas
-
Onyx9550
4 Páginas
-
Onyx® II, Model 9560
4 Páginas
-
Product catalog
21 Páginas