Focus laminar air flow Focused laminar flow systems: the air is filtered through hepa filters free of microorganisms and then directed immediately onto the surgical instruments and surgical site. It is only then distributed throughout the operating theatre. This protects the critical area of the operating theatre, i.e. the instruments and the surgical site. With this system, the bacterial load on the instruments and surgical site is reduced by more than 95% compared with conventional ventilation systems.
Abrir o catálogo na página 1
Conventional ventilation system Air filtered through conventional ventilation systems is first directed towards the floor and then distributed homogenously throughout the operating theatre. Despite all measure to maintain asepsis, the floor of the operating theatre is always contaminated. Thus bacteria can be transmitted to the patient through the instruments and surgical wound. Conventional ventilation systems cannot ensure a high degree of asepsis in the wound area as the sterile flow is always hindered by surgical lights and medical stuff thus favouring bacteria to wound area. In the...
Abrir o catálogo na página 2
Focus laminar air flow
Abrir o catálogo na página 3
Operating room with laminar air flow The traditional laminar air flow protect the instruments only inside the laminar air flow Most instruments are prepared outside the traditional laminar air flow and thus already being contaminated during the preparation.
Abrir o catálogo na página 4
Mixed ventilation system ZONA PROTETTA The clean “sterile air” is first touching the unsterile floor and then distributed in the O.R. There isn’t any real protected sterile area in the operating room to keep instruments or operating field sterile!
Abrir o catálogo na página 5
The clean “sterile air” is first touching the unsterile floor and then distributed in the O.R. There isn’t any real protected sterile area in the operating room to keep instruments or operating field steri
Abrir o catálogo na página 6
Study: Possible instrument contamination in the operating room during implantation of Knee and Hip Arthroplasty Thieme Verlag 2016)
Abrir o catálogo na página 7
Study: Possible instrument contamination in the operating room during implantation of Knee and Hip Arthroplasty Thieme Verlag 2016)
Abrir o catálogo na página 8
Instrument contamination after 60 minutes (*1,2) Conclusion: Only the instruments prepared inside the laminar air flow or with the focussed laminar air flow shows good aseptic results 1) Possible instrument contamination in the operating room during implantation of knee and hip arthroplasty. Journal for orthopedic and trauma surgery. April 2016, Germany 2) Influence of different ventilations systems upon the contamination of medical devices; Hyg Med 2013; 38 – 4
Abrir o catálogo na página 9
protected zone Enlarge your protected zone with focused laminar air flow
Abrir o catálogo na página 10
protected zone protected zone protected zone protected zone
Abrir o catálogo na página 11
protected zone
Abrir o catálogo na página 12
Consumation of antibiotics in Europe consumo per 1000 abitanti e per giorno
Abrir o catálogo na página 16
Klebsiella pneumoniae : percentuale di isolati invasivi resistenti ai carbapenemici wm i 50% No data reported or levs than 10 isolates i—i Notmduded * http://ecd-C.-eur,Qpa.eu/en/healthtopics/antimicrobial resistanc e/database/Pages/database.aspx
Abrir o catálogo na página 17
Escherichia coli: percentuale di isolati invasivi resistenti alla terza generazione di cefalosporina 2010 2014
Abrir o catálogo na página 18
Epidemiological stages of nationwide spread of CPE i i Countries not participating i i No case reported i i Sporadic occurrence l i Single hospital outbreak I I Sporadic hospital outbreaks i I Regional spread Inter-regional spread Endemic situation Non-visible countries Luxembourg Malta
Abrir o catálogo na página 19
Orthopaedic surgery: The focussed oriented laminar air flow can be placed to protect the instruments and the operating field. info@normeditec.com
Abrir o catálogo na página 22
Particle counting after 90 minutes with Toul focus laminar air flow without Toul laminar air flow
Abrir o catálogo na página 23
The helmets protects the operating field but not necessarily the instruments as they are placed outside !
Abrir o catálogo na página 24
Cardiac surgery Florence
Abrir o catálogo na página 25
Transplantation surgery Torino
Abrir o catálogo na página 26
Cardiac surgery San Michele Caserta
Abrir o catálogo na página 27
Cardiac surgery Udine
Abrir o catálogo na página 28
Cardiac surgery Rome Tor Vergate
Abrir o catálogo na página 29
The instruments can be prepared in every place of the operating room under sterile conditions. Afterwards the unit is transported to the operating field protecting both the instruments and the operating field. info@normeditec.com
Abrir o catálogo na página 30
Conventional Ophthalmology room Operio Ophthalmology room The focus laminar air flow keeps the instruments and the operating field extreme sterile as there are no obstacles like surgical lights or operating staff in between info@normeditec.com
Abrir o catálogo na página 31
Intravitreal injections Intravitreal injections should be given in a clean room. Operio provides with very high aseptic conditions. The aseptic conditions achieved with Operio are superior to any operating room due to the fact that the sterile air is immediately directed to the instrument table and operating field in combination with the use of hepa h14 filters . info@normeditec.com
Abrir o catálogo na página 32
Traceability with bar code system even after years!
Abrir o catálogo na página 34
Universita Uppsala Without focussed laminar air flow with focussed Laminar air flow
Abrir o catálogo na página 35
San Martino Genova instrument contamination Riduzione: 100 % Università degli studi di Genova Sossai –Dagnino 2007
Abrir o catálogo na página 36Todos os catálogos e folhetos técnicos Normeditec
-
HVAC system for eye surgery room
8 Páginas
-
Hospital tent for ophthalmic surgery
8 Páginas
-
low cost ventilation for IVOM
4 Páginas
-
Mobile operating theatres
4 Páginas
-
Tavi instrument table
3 Páginas
-
Mother table Operating room
4 Páginas
-
Operating Room Ventilation
16 Páginas
-
Operating Theatre Ventilation ISO 5
4 Páginas
-
Operating Theatre Ventilation ISO 5
4 Páginas
-
Laminar flow for orthopaedic surgery
3 Páginas
-
Periprosthetic joint infection
5 Páginas
-
Prevent Breast Implant Infections
3 Páginas
-
Ophthalmic Operating Theatre
2 Páginas