Excertos do catálogo

Your healthcare, we care. A9600 Anesthesia Workstation Technical Parameters ·Volume Control - Intermittent Positive Pressure Ventilation (IPPV) ·Pressure Control Ventilation (PCV) ·Synchronized Intermittent Mandatory Ventilation with Pressure Support (SIMV + PS) ·Pressure Support with Apnea backup (PS) ·Manual ·Apnea ·Apnea CO 2 ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Continuous Pressure ·O 2 Supply Fail ·Negative Pressure ·High Breath Rate (PS) ·High PEEP ·Mixed Agents ·Low Battery ·AC Power Fail ·Technical alarms Parameters and Ranges ·Pressure target: 5 – 70 cmH 2 O ·Pressure support (delta P): 3 – 50 cmH 2 O ·Tidal Volume: 20 – 1500 mL ·Breathing Freq.: 4-100 bpm 2-60 bpm in PS, SIMV ·T INSP : 0.2-5.0s ·PEEP: OFF, 3 - 30 cmH 2 O ·Freq MIN : 2 - 60 bpm ·T pause: OFF, 5%-60% ·Trigger: 1 – 15 L/min ·I:E Ratio: 4:1-1:8 ·T SLOPE : 0 – 2 s ·Vaporizers: Sevoflurane, Desflurane, Isoflurane, Halothane, Enflurane Monitoring Continuous monitoring of inspiratory O 2 concentration, breathing frequency, airway pressure (Paw, Peak, Pmean, PEEP), minute volume and tidal volume. The measured parameters are displayed as large, easy to read digital values. Airway pressure, flow and CO 2 (optional) are shown in graphical waveforms. Optional Gas Monitoring for CO 2 and 5 Anesthetic Agents with Agent Identification Inspiratory O 2 concentration (FiO 2 ) Minute Volume (MV) Airway pressure (PAW) EtCO 2 and agents Operation Conditions: ·Operating voltage: AC100-240V, 50Hz/60Hz ·Temperature: -20 - 50 ℃ ·Relative humidity: 15~95%, non-condensing (operating) ·Weight (without vaporizer & cylinders): approx. 120Kg ·Dimensions (H x W x D): approx. 1400mmX760mmX760mm Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA AL9000 September 2012
Abrir o catálogo na página 1
A9600 Anesthesia Workstation A9600 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation. It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician. A9600 includes Adult and Child modes that provide patient-appropriate defaults and ranges. A9600 has VCV, PCV and SIMV+PS automatic ventilation modes providing flexibility in your choice of ventilation strategy. It is suitable for pediatric and adult operation. A9600 is filled with many...
Abrir o catálogo na página 2
A9600 Anesthesia Workstation A9600 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation. It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician. A9600 includes Adult and Child modes that provide patient-appropriate defaults and ranges. A9600 has VCV, PCV and SIMV+PS automatic ventilation modes providing flexibility in your choice of ventilation strategy. It is suitable for pediatric and adult operation. A9600 is filled with many...
Abrir o catálogo na página 3
A9600 Anesthesia Workstation A9600 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation. It has a user-friendly design, incorporates new technology and provides safe and effective treatment options for the clinician. A9600 includes Adult and Child modes that provide patient-appropriate defaults and ranges. A9600 has VCV, PCV and SIMV+PS automatic ventilation modes providing flexibility in your choice of ventilation strategy. It is suitable for pediatric and adult operation. A9600 is filled with many...
Abrir o catálogo na página 4
Your healthcare, we care. A9600 Anesthesia Workstation Technical Parameters ·Volume Control - Intermittent Positive Pressure Ventilation (IPPV) ·Pressure Control Ventilation (PCV) ·Synchronized Intermittent Mandatory Ventilation with Pressure Support (SIMV + PS) ·Pressure Support with Apnea backup (PS) ·Manual ·Apnea ·Apnea CO 2 ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Continuous Pressure ·O 2 Supply Fail ·Negative Pressure ·High Breath Rate (PS) ·High PEEP ·Mixed Agents ·Low Battery ·AC Power Fail ·Technical alarms Parameters and...
Abrir o catálogo na página 5
Your healthcare, we care. A9600 Anesthesia Workstation Technical Parameters ·Volume Control - Intermittent Positive Pressure Ventilation (IPPV) ·Pressure Control Ventilation (PCV) ·Synchronized Intermittent Mandatory Ventilation with Pressure Support (SIMV + PS) ·Pressure Support with Apnea backup (PS) ·Manual ·Apnea ·Apnea CO 2 ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Adjustable alarm limits ·Continuous Pressure ·O 2 Supply Fail ·Negative Pressure ·High Breath Rate (PS) ·High PEEP ·Mixed Agents ·Low Battery ·AC Power Fail ·Technical alarms Parameters and...
Abrir o catálogo na página 6Todos os catálogos e folhetos técnicos Oricare
-
V8600 Ventilator
6 Páginas
-
L2700 Series Operating Room Lamps
12 Páginas
-
L2700 Series
6 Páginas
-
T3600
16 Páginas
-
T3600 Operating Table
8 Páginas
-
P1000 Series
12 Páginas
-
M7810 Patient Monitoring System
2 Páginas
-
Anesthetic A9040 Vaporizer
2 Páginas
-
P1000 Series Ceiling Pendant Systems
6 Páginas
-
C4500 Medical Air Compressor
2 Páginas
-
V8800
6 Páginas
-
A9800
6 Páginas
-
M7600/M7400
6 Páginas
-
M7800
6 Páginas
-
P1600 Series Supply Beam Systems
2 Páginas
-
V8800 Ventilator System
2 Páginas
Catálogos arquivados
-
T3600 Operating Table
6 Páginas
-
L2700 Series Operating Room Lamps
2 Páginas
-
A9600 Anesthesia Workstation
2 Páginas