Grupo: Lumibird Medical
Excertos do catálogo

optimiB Fusion NEXT GENERATION SLT/YAG LASER LUMIBIRD MEDICAL
Abrir o catálogo na página 1
Quantel Medical’s cutting edge laser technology has brought constant and multiple innovations to ophthalmologists worldwide since 1993. Optimis Fusion combines traditional YAG photodisruption treatments and advanced SLT photoregenaration therapy in one integrated platform. Optimis™ Fusion from Quantel Medical The Next Generation of SLT/YAG Technology Quantel Medical’s proprietary technology is based on an engineering breakthrough, which enables infrared and visible green nanosecond pulses to be produced by a single dual-mode cavity reducing complexity and resulting in a more elegant,...
Abrir o catálogo na página 2
l ibird Medica Lum l, a brand of ca uantel Medi Q Gentle Laser Delivery No Thermal Damage. Repeatable. Selective Laser Trabeculoplasty (SLT) targets melanin rich cells which absorb the laser energy to induce a healing response that begins to restore the function of the trabecular meshwork. The laser energy is delivered in short, fixed pulses over a large, homogeneous spot size, resulting in no thermal damage. Due to the gentle delivery and no permanent destruction to the trabecular meshwork, SLT leaves the structures intact and can be repeated if necessary. YAG Mode The YAG mode delivers...
Abrir o catálogo na página 3
A Glaucoma, Cataract and Retina Laser in One
Abrir o catálogo na página 4
First choice treatment for managing glaucoma and lowering IOP. Repeatable Proven Gentle and non-invasive Primary or adjunct therapy No compliance issues No side effects*
Abrir o catálogo na página 5
Laser source: Q-switched, frequency doubled Nd:YAG Q-switched Nd:YAG Energy levels/Power: Pulse duration/Exposure: Spot Size: 10 microns (86.4% energy in diameter) 8 microns FWHM Repetition rate: Offset: (Anterior and Posterior) Pulse mode: Single pulse COMMON TO BOTH Aiming beam: Slit lamp: Size (laser only): Weight (laser only): Power requirements: Delivery Systems: AVAILABLE MODELS Optimis™ Fusion system Optimis™ Fusion and VITRA 2® SingleSpot laser platform 0459 Manufacturer Quantel Medical 1 Rue du Bois Joli – CS40015 63808 Cournon d’Auvergne – FRANCE Tel.: +33 (0)4 73 745 745 Email:...
Abrir o catálogo na página 6Todos os catálogos e folhetos técnicos Quantel Medical - Ophthalmology
-
Vitra 810, Glaucoma treatment
6 Páginas
-
C.DIAG, ULTRA SMART POWERFUL IMAGING
5 Páginas
-
EASYRET
5 Páginas
-
Vitra 689, Next generation PDT laser
2 Páginas
-
AXIalis, biometry and pachymetry
3 Páginas
-
CSTIM, IPL for dry eye treatment
5 Páginas