Grupo: Randox

Excertos do catálogo

Biochip Array Technology explained The 'Gold Standard' in multiplex testing
Abrir o catálogo na página 1
Biochip Background Established in 1982, Randox is a market leader in the field of high quality diagnostic solutions. With origins in clinical chemistry, Randox adapted its expertise and product range to include immunoassays, quality management and life science solutions. Randox’s vision is to develop innovative and clinically meaningful diagnostics, ultimately improving laboratory testing and healthcare solutions worldwide. Approximately 2% of all healthcare costs are diagnostics; however, 70-80% of all clinical decisions are based on the results of diagnostic tests. Traditionally six or...
Abrir o catálogo na página 2
Put simply, Biochip Array Technology is a multi-analyte testing platform allowing the simultaneous quantitative or qualitative detection of a wide range of analytes from a single sample. It provides a unique platform for assessment of biological samples in a rapid, accurate and easy to use format. The problem with traditional diagnosis Traditional diagnosis takes the form of single analyte assays, even though several tests are usually required. This may result in multiple patient blood draws, increased reagent volume, ultimately increasing time to diagnosis. The solution In response, Randox...
Abrir o catálogo na página 3
Biochip sheets ready for spotting Formatting equipment delivers the droplets of antibody A camera takes an image of every biochip QUALITY CONTROL Many years of development and the exper tise of highly qualified scientists have gone into the creation of the Biochip. We have integrated various different innovative technologies into the biochip production process. Some of which include: Quality is a top priority at Randox throughout our entire product range. The process of ensuring high standards begins at the research stage and is continued into manufacturing, therefore producing a final...
Abrir o catálogo na página 4
ASSAY FORMATS Protein / Antibody assay formats Competitive immunoassay In a competitive immunoassay, the more analyte present in a sample, the less labelled conjugate that will bind to the immunoreaction site. Therefore the signal produced will be low. If there is little analyte in the sample, more labelled conjugate will bind to the capture antibody resulting in a higher signal. Sandwich immunoassay In a sandwich immunoassay, the more analyte present in a sample, the more conjugate will bind to the capture antibody. As a result, the signal will be high. Conversely, lower signal is produced...
Abrir o catálogo na página 5
The biochip detection system is based on a chemiluminescent signal. This is the emission of light, without heat, as a result of a chemical reaction. An enzyme is used to catalyse the chemical reaction on the biochip which generates the chemiluminescent signal. The light emitted from the chemiluminescent reaction that takes place in each DTR is simultaneously detected and quantified using a Charge - Coupled Device (CCD) Camera. This CCD Camera simultaneously records the light emission from all the discrete test sites on each biochip on the biochip carrier. Analysis process on biochip systems...
Abrir o catálogo na página 6
Key Features and Benefits Highly accurate testing • BAT has a proven high standard of accurate test results with CV’s <10% • Multiplex analysis minimises analytical variation between tests Better patient diagnosis • Testing for multiple markers simultaneously increases the amount of patient information rapidly available to the clinician, allowing for more informed patient diagnosis Optimum efficiency • M ulti-analyte reagents and quality control material, provides highly efficient testing while eliminating any wastage Small sample volume • Reduced sample volume requirements puts the patient...
Abrir o catálogo na página 7
Biochip Test Menu Clinical Arrays Cardiac Array Creatine-Kinase Muscle Brain (CK-MB) Heart Type Fatty Acid Binding Protein (H-FABP) Myoglobin(Myo) Troponin I (cTnI) Thyroid Total Array Thyroid Stimulating Hormone (TSH) Total Thyroxine (TT4) Total Tri-iodothyronine (TT3) Fertility Hormone Array Estradiol (EST) Follicle Stimulating Hormone (FSH) Luteinising Hormone (LH) Progesterone (PROG) Prolactin (PRL) Testosterone (TEST) Vitamin D Array* Vitamin D (VITD) Thyroid Free Array Free Thyroxine (FT4) Free Tri-iodothyronine (FT3) Thyroid Stimulating Hormone (TSH) Tumour PSA Array Carcinoembryonic...
Abrir o catálogo na página 8
Biochip Test Menu Toxicology Arrays Drugs of Abuse Array I Plus Amphetamine Barbiturates Benzodiazepine 1 Benzodiazepine 2 Buprenorphine Cannabinoids Cocaine metabolite (Benzoylecgonine) MDMA Methadone Methamphetamine Opiates Phencyclidine Tricyclic Antidepressants (TCAs Generic) Drugs of Abuse Array III Chloral Hydrate Metabolite Ethyl Glucuronide Fentanyl Ketamine Metabolite Meperidine Meprobamate Zaleplon Zolpidem Zopiclone Flunitrazepam Drugs of Abuse Array IV Acetaminophen Dextromethorphan Escitalopram Drugs of Abuse Array II Buprenorphine Ethyl Glucuronide Fentanyl Fluoxetine Generic...
Abrir o catálogo na página 9
Biochip Test Platforms Fully automated, floor standing Random Access Ideal for STAT samples Multiple tests from 7µl sample Sample matrices include plasma, serum, whole blood Capacity for 200 biochips onboard Barcode scanner for sample traceability Bar-coded samples and RF1D-tagged reagents Applicable for all standard collection tubes Robust Bio-drive robotics Integrated Graphical User Interface Automatic software update via internet Probe liquid level, clot and bubble detection Real time data filtering and reporting User-defined cut-off levels without recalibration Extensive QC data...
Abrir o catálogo na página 10
Biochip Test Platforms Fully automated, floor standing Multiple tests from 7µl sample Barcode scanner for sample traceability Bar-coded samples and reagents Internal back-up stores over 6 years of results User-defined cut-off levels without recalibration Extensive QC data generation Retrospective reporting Automatic disposal of biochips Chain of custody features Suitable for high throughput laboratories Onboard refrigeration of reagents Semi-automated, bench-top Multiple tests from 25µl sample Ability to store and retrieve work lists saving time Barcode scanner for sample traceability...
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos Randox Laboratories
-
LT735 Vivalytic Overview
32 Páginas
-
Acusera New Controls
8 Páginas
-
Acusera 24.7
24 Páginas
-
Acusera Third Party Controls
108 Páginas
-
Acusera SMART Controls
12 Páginas
-
Company Overview
40 Páginas
-
EDUCATIONAL GUIDE Gastroenteritis
12 Páginas
-
Superior Performance & Unique Tests
32 Páginas
-
Reagents Brochure
64 Páginas
-
sdLDL-C
8 Páginas
-
RX SERIES ANALYSER OVERVIEW
24 Páginas
-
RX modena
20 Páginas
-
RX misano
20 Páginas
-
RX Daytona Plus
20 Páginas
-
Rx Imola
20 Páginas
-
RX Monaco
20 Páginas
-
2024 Product List
64 Páginas
-
LT107 Evidence Investigator
32 Páginas
-
VeraSTAT-V
16 Páginas
-
LT033 RIQAS Explained
64 Páginas
-
VERASTAT
16 Páginas
-
Endocrine Array
4 Páginas
-
Cerebral Arrays
4 Páginas
-
Thyroid Arrays
4 Páginas
-
Respiratory Multiplex Array
8 Páginas
-
LT252 Respiratory Multiplex Array
8 Páginas
-
LT253 Molecular Diagnostics
20 Páginas
-
LT367 FH Array Brochure
4 Páginas
-
The role of EQA in QC
8 Páginas
-
Basic QC Stastics
8 Páginas
-
Commutability Guide
4 Páginas
-
How to measure uncertainty
8 Páginas
-
ISO 15189 Educational Guide
8 Páginas
-
Meeting ISO 15189 Requirements
4 Páginas
-
QC Multirules Educational Guide
8 Páginas
-
Troubleshooting QC Errors
8 Páginas
-
Qnostics
52 Páginas
-
Adiponectin LT519
28 Páginas
-
Specific Proteins
40 Páginas
-
Linearity sets
12 Páginas
-
Antioxidants
16 Páginas
-
Cardiology & Lipid Testing
28 Páginas
-
Diabetes Portfolio
28 Páginas
-
Total Bile Acids
4 Páginas
-
VIVALYTIC
30 Páginas
-
RANDOX DISCOVERY
36 Páginas
-
HbA1c
2 Páginas
-
technology at your fingertips
2 Páginas
-
RIQAS Troubleshooting checklist
1 Páginas
-
Preparing QC
1 Páginas
-
Point of Care Testing
12 Páginas
-
LT630 Monitoring EQA Performance
1 Páginas
-
LT394 Using QC Multirules
1 Páginas
-
Guide to running QC
1 Páginas
-
Tumour Marker Arrays
4 Páginas
-
Which QC is the Right QC
8 Páginas
-
How often is right for QC
6 Páginas
-
Cardiac Risk Multiplex Array
4 Páginas
-
LT250 STI Multiplex Array NOV14
8 Páginas
-
LT241 Metabolic Array MAY15
8 Páginas
-
KRAS / BRAF / PIK3CA Array*
4 Páginas
-
Custom Arrays for Biochip
12 Páginas
-
LT169 Cardiac Array
4 Páginas
Catálogos arquivados
-
ACUSERA
108 Páginas
-
Evidence Evolution
28 Páginas
-
Evidence
16 Páginas
-
Metabolic Syndrome Arrays
8 Páginas
-
STI Multiplex Array
8 Páginas
-
Molecular Testing
16 Páginas
-
Evidence Investigator
20 Páginas
-
Fertility Array
4 Páginas
-
LT107 Evidence Investigator - 2014
20 Páginas
-
Rx Daytona
16 Páginas
-
Evidence Investigator
16 Páginas
-
Evidence
16 Páginas