
Grupo: Randox

Excertos do catálogo

CARDIOLOGY & LIPID TESTING COMPLETE CARDIOLOGY & LIPID TESTING FROM RANDOX
Abrir o catálogo na página 1
CARDIOLOGY & LIPID TESTING Complete Cardiology and Lipid Testing from Randox
Abrir o catálogo na página 2
sdLDL CHOLESTEROL APOLIPOPROTEIN C-III DIAGNOSTIC BIOCHIP PRODUCTS RESEARCH BIOCHIP PRODUCTS ORDERING INFORMATION GLOBAL DIAGNOSTIC SOLUTIONS PROVIDER NP NICHE PRODUCT When you see this symbol you will know that Randox have one of the only automated biochemistry assays available on the market UF UNIQUE FEATURE When you see this symbol you will know that this feature is unique to the Randox product
Abrir o catálogo na página 3
BENEFITS OF RANDOX REAGENTS Randox offers an extensive range of third party diagnostic reagents which are internationally recognised as being of the highest quality; producing accurate and precise results. We have a considerable test menu of over 100 assays, covering over 100 disease markers including: antioxidants, diabetes, drugs of abuse testing, lipids, specific proteins, therapeutic drug monitoring and veterinary testing. EXPAND YOUR TEST MENU WITHOUT EXPANDING YOUR LAB There is no need to buy any extra equipment in order to expand your test menu. Our reagents can be programmed onto...
Abrir o catálogo na página 4
INTRODUCTION TO RANDOX CARDIOLOGY AND LIPID TESTING International bodies, including the National Lipid Association and the European Guidelines on Cardiovascular Disease (CVD) Prevention in Clinical Practice advocate measuring lipids to truly identify CVD risk. However, the traditional lipid panel of cholesterol, HDL-C, triglycerides and LDL-C only detect approximately 20% of all coronary artery disease (CAD) patients. Advanced lipid testing is recommended to optimise patient treatment, both in primary and secondary risk categories and as such provide the necessary tools to prevent and...
Abrir o catálogo na página 5
HDL CHOLESTEROL Clinical Significance Key Features of the Randox HDL Cholesterol Assay UF High-density lipoproteins (HDL) are one of the major classes of plasma lipoproteins. HDL-C is often referred to as ‘good cholesterol’ as it transports from the tissues to the liver for removal from the body. High levels of HDL-C can lower the risk of developing heart disease. Superior direct clearance methodology ensuring truly accurate results even with abnormal samples Liquid ready-to-use reagents for convenience and ease of use Extensive measuring range of 0.189 - 3.73mmol/L Applications available...
Abrir o catálogo na página 6
Fig. 3 Specificity of Randox Direct Clearance Assay for HDL Cholesterol Specificity of the Randox direct clearance HDL-C assay was verified against gel filtration. Fig. 3 indicates how specific the Randox direct clearance method is for HDL-C. Our kit was found to only react with the HDL-C fractions separated by gel filtration. Total Cholesterol Reagent 1 Randox HDL Cholesterol Reagent THE DIAGRAM ABOVE SHOWS HOW SPECIFIC THE RANDOX DIRECT CLEARANCE METHOD IS All ordering information can be found on Page 20-2
Abrir o catálogo na página 7
LDL CHOLESTEROL Key Features of the Randox LDL Cholesterol Assay • • • • UF Superior direct clearance methodology ensuring truly accurate results are delivered Liquid ready-to-use reagents for convenience and ease-of-use Extensive measuring range of 0.189 – 22.2mmol/L for the measurement of clinically significant levels Applications available detailing instrument-specific settings for the convenient use of the Randox LDL Cholesterol (LDL-C) assay on a wide range of clinical chemistry analysers Benefits of the Randox Direct Clearance Method The Randox direct clearance method eliminates...
Abrir o catálogo na página 8
Fig. 5 Specificity of the Randox Direct Clearance Assay for LDL Cholesterol Specificity of the Randox direct clearance LDL-C assay was verified against gel filtration. Fig. 5 indicates how specific the Randox direct clearance method is for LDL-C. Our kit was found to only react with the LDL-C fractions separated by gel filtration. Randox LDL Cholesterol Total Cholesterol 1 THE FRIEDEWALD FORMULA HAS BEEN REPORTED TO MISCLASSIFY UP TO 50% OF PATIENTS3 % of samples misestimated by more than 10% All ordering information can be found on Page 20-2
Abrir o catálogo na página 9
TOTAL CHOLESTEROL & TRIGLYCERIDES Triglycerides: recommended levels below Cholesterol: recommended levels below CHOLESTEROL (TOTAL) Key Features of the Randox Cholesterol Assay Key Features of the Randox Triglycerides Assay Wide range of kits available ensuring laboratories of all sizes can find a product to suit their needs Liquid ready-to-use reagents for convenience and ease-of-use Standards included in certain kits for user convenience (these are for manual and semi-automated use only) Extensive measuring range of 0.865-16.6 mmol/L for the measurement of clinically significant levels...
Abrir o catálogo na página 10
sdLDL CHOLESTEROL SMALL-DENSE LDL CHOLESTEROL (sdLDL-C) Fig. 6 Correlation of Ultracentrifugation and Denka Seiken Methods. 6 Key Features of the Randox sdLDL Cholesterol Assay Until recently, the primary methods of assessing a patient’s sdLDL-C levels were based on techniques such as ultracentrifugation and electrophoresis both of which are extremely laborious and time-consuming. 4 sdLDL-C can now be assessed in the routine biochemistry laboratory using the Randox Clearance assay. • Randox sdLDL-C utilises the clearance method which produces results in ten minutes. There are two main...
Abrir o catálogo na página 11
Criteria to overcome challenges of Lp(a) measurement Traditional challenges of Lp(a) measurement The widespread use of Lp(a) as an independent risk factor for cardiovascular disease risk has, until recently, been impeded by the lack of internationally accepted standardisation and the fact that many commercial Lp(a) methods suffer from apolipoprotein (a) (apo(a)) size related bias, potentially leading to patient misclassification. The size heterogeneity of apo(a) affects, to varying degrees the results of many commercially available Lp(a) kits. This may result in an underestimation of Lp(a)...
Abrir o catálogo na página 12
Clinical Significance The determination of Lp(a) levels is intended for use in conjunction with the clinical evaluation, patient risk assessment and other lipid tests to evaluate disorders of lipid metabolism and to assess coronary heart disease in specific populations. The size of the apo(a) protein is genetically determined and varies widely. As such, the levels of Lp(a) can vary up to 1000-fold between individuals.9 Recent years have seen major scientific advances in the understanding of Lp(a) and its causal role in premature cardiovascular disease (CVD). Elevated Lp(a) levels are...
Abrir o catálogo na página 13Todos os catálogos e folhetos técnicos Randox Laboratories
-
LT735 Vivalytic Overview
32 Páginas
-
Acusera New Controls
8 Páginas
-
Acusera 24.7
24 Páginas
-
Acusera Third Party Controls
108 Páginas
-
Acusera SMART Controls
12 Páginas
-
Company Overview
40 Páginas
-
EDUCATIONAL GUIDE Gastroenteritis
12 Páginas
-
Superior Performance & Unique Tests
32 Páginas
-
Reagents Brochure
64 Páginas
-
sdLDL-C
8 Páginas
-
RX SERIES ANALYSER OVERVIEW
24 Páginas
-
RX modena
20 Páginas
-
RX misano
20 Páginas
-
RX Daytona Plus
20 Páginas
-
Rx Imola
20 Páginas
-
RX Monaco
20 Páginas
-
2024 Product List
64 Páginas
-
LT107 Evidence Investigator
32 Páginas
-
VeraSTAT-V
16 Páginas
-
LT033 RIQAS Explained
64 Páginas
-
VERASTAT
16 Páginas
-
Endocrine Array
4 Páginas
-
Cerebral Arrays
4 Páginas
-
Thyroid Arrays
4 Páginas
-
Respiratory Multiplex Array
8 Páginas
-
LT252 Respiratory Multiplex Array
8 Páginas
-
LT253 Molecular Diagnostics
20 Páginas
-
LT367 FH Array Brochure
4 Páginas
-
The role of EQA in QC
8 Páginas
-
Basic QC Stastics
8 Páginas
-
Commutability Guide
4 Páginas
-
How to measure uncertainty
8 Páginas
-
ISO 15189 Educational Guide
8 Páginas
-
Meeting ISO 15189 Requirements
4 Páginas
-
QC Multirules Educational Guide
8 Páginas
-
Troubleshooting QC Errors
8 Páginas
-
Qnostics
52 Páginas
-
Adiponectin LT519
28 Páginas
-
Specific Proteins
40 Páginas
-
Linearity sets
12 Páginas
-
Antioxidants
16 Páginas
-
Diabetes Portfolio
28 Páginas
-
Total Bile Acids
4 Páginas
-
VIVALYTIC
30 Páginas
-
RANDOX DISCOVERY
36 Páginas
-
HbA1c
2 Páginas
-
technology at your fingertips
2 Páginas
-
RIQAS Troubleshooting checklist
1 Páginas
-
Preparing QC
1 Páginas
-
Point of Care Testing
12 Páginas
-
LT630 Monitoring EQA Performance
1 Páginas
-
LT394 Using QC Multirules
1 Páginas
-
Guide to running QC
1 Páginas
-
Tumour Marker Arrays
4 Páginas
-
Which QC is the Right QC
8 Páginas
-
How often is right for QC
6 Páginas
-
Cardiac Risk Multiplex Array
4 Páginas
-
Biochip Array Technology explained
12 Páginas
-
LT250 STI Multiplex Array NOV14
8 Páginas
-
LT241 Metabolic Array MAY15
8 Páginas
-
KRAS / BRAF / PIK3CA Array*
4 Páginas
-
Custom Arrays for Biochip
12 Páginas
-
LT169 Cardiac Array
4 Páginas
Catálogos arquivados
-
ACUSERA
108 Páginas
-
Evidence Evolution
28 Páginas
-
Evidence
16 Páginas
-
Metabolic Syndrome Arrays
8 Páginas
-
STI Multiplex Array
8 Páginas
-
Molecular Testing
16 Páginas
-
Evidence Investigator
20 Páginas
-
Fertility Array
4 Páginas
-
LT107 Evidence Investigator - 2014
20 Páginas
-
Rx Daytona
16 Páginas
-
Evidence Investigator
16 Páginas
-
Evidence
16 Páginas