
Grupo: Randox

Excertos do catálogo

Monitoring EQA Performance : Investigating the source of the problem In order to identify the source of the problem it is useful to be aware of the most common causes of poor EQA performance. Errors can occur at any stage of the testing process however EQA is most concerned with detecting analytical errors i.e. errors that occur during the analysis of the sample. Most analytical errors can be easily divided into three main areas; clerical errors, systematic errors and random errors. Systematic errors result in inaccurate results that consistently show a positive or negative bias. Random errors on the other hand affect precision and result in fluctuations in either direction. The flowchart (below) is designed to help you investigate any apparent poor performance. Is the parameter result within acceptable limits of performance? YES • Target Score >50 • SDI <2SDPA • % Deviation < acceptable limits of performance Send corrected result to RIQAS along with relevant documentation to support the case. Verify instrument, method and units are registered correctly for each parameter. Especially important for initial submission and when registration changes have been made. Review the summary page. Are the majority of results flagged? Advise RIQAS of correct details Review Levey-Jennings charts. Are any points outside +/- 1SD? Review instrument parameters and calibration. Has the reagent batch been changed? Review IQC results from the time the EQA sample was tested. Look for trends within the data • Positive/Negative bias • Poor precision • Changes in performance due to change in reagent, calibrator or standardisation There may be a problem specific to that sample • Incorrect sample tested • Reconstitution error • Sample storage Look for shifts or trends Investigate and take corrective action The largest global EQA scheme QUALITY CONTROL Information correct at time of print. Randox Laboratories Ltd is a subsidiary of Randox Holdings Limited a company registered within Northern Ireland with company number N.I. 614690. VAT Registered Number: GB 151 6827 08. Product availability may vary from country to country. Please contact your local Randox representative for information. Products may be for Research Use Only and not for use in diagnostic procedures in the USA. Review performance over the cycle Verify that the reported result and units reflect what was obtained. Has a transcription
Abrir o catálogo na página 1Todos os catálogos e folhetos técnicos Randox Laboratories
-
LT735 Vivalytic Overview
32 Páginas
-
Acusera New Controls
8 Páginas
-
Acusera 24.7
24 Páginas
-
Acusera Third Party Controls
108 Páginas
-
Acusera SMART Controls
12 Páginas
-
Company Overview
40 Páginas
-
EDUCATIONAL GUIDE Gastroenteritis
12 Páginas
-
Superior Performance & Unique Tests
32 Páginas
-
Reagents Brochure
64 Páginas
-
sdLDL-C
8 Páginas
-
RX SERIES ANALYSER OVERVIEW
24 Páginas
-
RX modena
20 Páginas
-
RX misano
20 Páginas
-
RX Daytona Plus
20 Páginas
-
Rx Imola
20 Páginas
-
RX Monaco
20 Páginas
-
2024 Product List
64 Páginas
-
LT107 Evidence Investigator
32 Páginas
-
VeraSTAT-V
16 Páginas
-
LT033 RIQAS Explained
64 Páginas
-
VERASTAT
16 Páginas
-
Endocrine Array
4 Páginas
-
Cerebral Arrays
4 Páginas
-
Thyroid Arrays
4 Páginas
-
Respiratory Multiplex Array
8 Páginas
-
LT252 Respiratory Multiplex Array
8 Páginas
-
LT253 Molecular Diagnostics
20 Páginas
-
LT367 FH Array Brochure
4 Páginas
-
The role of EQA in QC
8 Páginas
-
Basic QC Stastics
8 Páginas
-
Commutability Guide
4 Páginas
-
How to measure uncertainty
8 Páginas
-
ISO 15189 Educational Guide
8 Páginas
-
Meeting ISO 15189 Requirements
4 Páginas
-
QC Multirules Educational Guide
8 Páginas
-
Troubleshooting QC Errors
8 Páginas
-
Qnostics
52 Páginas
-
Adiponectin LT519
28 Páginas
-
Specific Proteins
40 Páginas
-
Linearity sets
12 Páginas
-
Antioxidants
16 Páginas
-
Cardiology & Lipid Testing
28 Páginas
-
Diabetes Portfolio
28 Páginas
-
Total Bile Acids
4 Páginas
-
VIVALYTIC
30 Páginas
-
RANDOX DISCOVERY
36 Páginas
-
HbA1c
2 Páginas
-
technology at your fingertips
2 Páginas
-
RIQAS Troubleshooting checklist
1 Páginas
-
Preparing QC
1 Páginas
-
Point of Care Testing
12 Páginas
-
LT394 Using QC Multirules
1 Páginas
-
Guide to running QC
1 Páginas
-
Tumour Marker Arrays
4 Páginas
-
Which QC is the Right QC
8 Páginas
-
How often is right for QC
6 Páginas
-
Cardiac Risk Multiplex Array
4 Páginas
-
Biochip Array Technology explained
12 Páginas
-
LT250 STI Multiplex Array NOV14
8 Páginas
-
LT241 Metabolic Array MAY15
8 Páginas
-
KRAS / BRAF / PIK3CA Array*
4 Páginas
-
Custom Arrays for Biochip
12 Páginas
-
LT169 Cardiac Array
4 Páginas
Catálogos arquivados
-
ACUSERA
108 Páginas
-
Evidence Evolution
28 Páginas
-
Evidence
16 Páginas
-
Metabolic Syndrome Arrays
8 Páginas
-
STI Multiplex Array
8 Páginas
-
Molecular Testing
16 Páginas
-
Evidence Investigator
20 Páginas
-
Fertility Array
4 Páginas
-
LT107 Evidence Investigator - 2014
20 Páginas
-
Rx Daytona
16 Páginas
-
Evidence Investigator
16 Páginas
-
Evidence
16 Páginas