Grupo: Randox

Excertos do catálogo

VIVALYTIC THE ALL IN ONE MOLECULAR SOLUTION
Abrir o catálogo na página 1
MAKING A POINT TO CARE 55 Diamond Road, Crumlin, Co. Antrim, United Kingdom, BT29 4QY Email. marketing@randox.com Tel. +44 (0) 28 9442 2413
Abrir o catálogo na página 2
CONTENTS Vivalytic & Cartridges Vivalytic Vivalytic Cartridges Vivalytic Workflow Vivalytic Test Menu Respiratory Infection Testing Hospital Acquired Infection Testing Genitourinary Infection Testing Vivalytic Specification Specifications Vivasuite Vivalytic Ordering Information Ordering Information
Abrir o catálogo na página 3
Vivalytic & Cartridges
Abrir o catálogo na página 5
Vivalytic Molecular Diagnostics at the Point of Care Vivalytic brings innovation to the Molecular Diagnostic testing market. It is the result of a successful collaboration between German technology expert, Bosch Healthcare Solutions and Randox Laboratories, a global IVD company and one of Bosch’s first bio-content partners. Bosch Healthcare Solutions has developed the Vivalytic system, which includes the test cartridge and analyser. Randox as the first partner on the Vivalytic platform, supplies Bosch with biological components needed inside the test cartridges to detect different pathogens...
Abrir o catálogo na página 6
Vivalytic Cartridges Vivalytic cartridges are compact, technologically advanced Molecular Diagnostic tests utilising micro-fluidics to enable simple and accurate diagnostic testing. Vivalytic cartridges are powered by a variety of technologies, dependent upon the test application. High-Plex and Low-Plex tests can be analysed on the Vivalytic system. High-Plex tests utilise Randox patented Biochip Array Technology, enabling end-point qualitative PCR and providing multiple test results simultaneously from one patient sample. Low-Plex tests are based on a variety of detection methods including...
Abrir o catálogo na página 8
High-Plex Vivalytic Cartridges Powered by Randox Biochip Technology Randox patented Biochip Technology allows simultaneous detection of multiple targets from a single patient sample. The biochip detection system is based on a chemiluminescent signal as a result of a chemical reaction. Each biochip is prefabricated with spatially discrete testing regions (DTR’s). Each DTR represents an individual test. Each DTR can be occupied with oligonucleotides specific to a pathogen or target of interest. The High-Plex capabilities of Biochip Technology eliminates the need to run multiple time consuming...
Abrir o catálogo na página 9
Vivalytic Workflow 4 Easy Steps for Optimised Workflow Intuitive engineering of Vivalytic ensures the analyser is user friendly. The process of patient sample to result comprises a very simple 4 step workflow. To begin the test, the user scans or enters sample information. The cartridge code is then scanned into the embedded Vivalytic software. The user then adds sample into the dedicated cartridge slot, closes the lid and inserts the cartridge into the Vivalytic. The touchscreen display will countdown the time remaining to test completion. Results will be displayed on the screen. Multiple...
Abrir o catálogo na página 10
Vivalytic Test Menu
Abrir o catálogo na página 13
Respiratory SARS-CoV-2 Dual Target SARS-CoV-2 dual target real time PCR cartridge provides clear and concise results in a timely manner, direct at the point of care. This enables individuals to take the recommended safety precautions without delay. The SARS-CoV-2 dual target rapid test allows for detection of both the E-gene and N-gene sequence. Sample Type: Nasopharyngeal or Oropharyngeal Swab (eNAT) Sample Volume: 300 μL Detection Method: Real-Time PCR Time to Result: 53 minutes VIRUS SARS-CoV-2 (E gene and N gene sequence) SARS-CoV-2, Flu A/B, and RSV Patients infected with SARS-CoV-2,...
Abrir o catálogo na página 14
Vivalytic MPXV The Vivalytic MPXV test is a rapid, user-friendly tool to support the global response against Monkeypox. This zoonotic virus, part of the Orthopoxvirus genus, spreads through animal bites, bodily fluids, and human contact via lesions, respiratory droplets, or contaminated objects. Sexual contact is a key transmission method during outbreaks. The Vivalytic MPXV Panel detects Monkeypox and non-variola orthopoxviruses, delivering fast and accurate results in just 45 minutes, aiding in outbreak control and prevention. Sample Type: Swab Sample Volume: 300 μL Detection Method:...
Abrir o catálogo na página 15
Hospital Acquired Infections MRSA/SA MRSA/SA is a qualitative test detecting and differentiating between methicillin-resistant Staphylococcus aureus (MRSA), methicillin-sensitive Staphylococcus aureus (MSSA) and methicillin-resistant coagulasenegative Staphylococci (MRCoNS). By using one single cartridge, the Vivalytic MRSA/SA test aids in the diagnosis of MRSA infection in a speedy manner so that appropriate antibiotic treatment can be applied, and complications prevented. Sample Type: Nasal or Oropharyngeal swab in liquid amies Sample Volume: 600 μL Detection Method: Real-Time PCR Time to...
Abrir o catálogo na página 16
Vivalytic Bacterial Meningitis Bacterial meningitis, an infectious disease-causing inflammation of the meninges, has significant global morbidity and mortality. Despite early diagnosis and adequate treatment, 8-15% of patients die within 2448 hours of symptom onset. Prompt and proper diagnosis and treatment are crucial to prevent death and lifelong disability among survivors. The introduction and widespread use of vaccines have led to a substantial decrease in meningitis cases, reducing global deaths by 21% from 1990 to 2016. Young children are at the highest risk, with new-borns vulnerable...
Abrir o catálogo na página 17
Vivalytic Norovirus Noroviruses are known as causing winter-vomiting disease or stomach-flu referring to their rapid spread in human populations especially during the winter period. Norovirus causes most of all gastrointestinal infections and are highly contagious. Rotaviruses are the very cause of severe diarrhoeal illness in infants and young children. Transmission mostly takes place in healthcare institutions such as hospitals, patient to patient, contaminated hands of healthcare workers or by environmental contamination. Sample Type: Swab samples from liquid or soft human stool...
Abrir o catálogo na página 18
Genitourinary Sexually Transmitted Infections (STI) The Sexually Transmitted Infections (STI) is the broadest cartridge-based STI panel on the market. The test simultaneously detects 10 bacterial, viral and protozoan infections for a comprehensive sexual health profile. Sample Type: Swab or Urine (eNAT, Roche COBAS medium, or PBS) Sample Volume: 300 μL Detection Method: Randox Biochip Technology (end-point PCR) Time to Result: 2 hours 20 minutes INFECTIONS Chlamydia trachomatis (CT) Herpes simplex virus 1 (HSV-1) Herpes simplex virus 2 (HSV-2) Treponema pallidum (Syphilis) (TP) MG, MH,...
Abrir o catálogo na página 19Todos os catálogos e folhetos técnicos Randox Laboratories
-
Acusera New Controls
8 Páginas
-
Acusera 24.7
24 Páginas
-
Acusera Third Party Controls
108 Páginas
-
Acusera SMART Controls
12 Páginas
-
Company Overview
40 Páginas
-
EDUCATIONAL GUIDE Gastroenteritis
12 Páginas
-
Superior Performance & Unique Tests
32 Páginas
-
Reagents Brochure
64 Páginas
-
sdLDL-C
8 Páginas
-
RX SERIES ANALYSER OVERVIEW
24 Páginas
-
RX modena
20 Páginas
-
RX misano
20 Páginas
-
RX Daytona Plus
20 Páginas
-
Rx Imola
20 Páginas
-
RX Monaco
20 Páginas
-
2024 Product List
64 Páginas
-
LT107 Evidence Investigator
32 Páginas
-
VeraSTAT-V
16 Páginas
-
LT033 RIQAS Explained
64 Páginas
-
VERASTAT
16 Páginas
-
Endocrine Array
4 Páginas
-
Cerebral Arrays
4 Páginas
-
Thyroid Arrays
4 Páginas
-
Respiratory Multiplex Array
8 Páginas
-
LT252 Respiratory Multiplex Array
8 Páginas
-
LT253 Molecular Diagnostics
20 Páginas
-
LT367 FH Array Brochure
4 Páginas
-
The role of EQA in QC
8 Páginas
-
Basic QC Stastics
8 Páginas
-
Commutability Guide
4 Páginas
-
How to measure uncertainty
8 Páginas
-
ISO 15189 Educational Guide
8 Páginas
-
Meeting ISO 15189 Requirements
4 Páginas
-
QC Multirules Educational Guide
8 Páginas
-
Troubleshooting QC Errors
8 Páginas
-
Qnostics
52 Páginas
-
Adiponectin LT519
28 Páginas
-
Specific Proteins
40 Páginas
-
Linearity sets
12 Páginas
-
Antioxidants
16 Páginas
-
Cardiology & Lipid Testing
28 Páginas
-
Diabetes Portfolio
28 Páginas
-
Total Bile Acids
4 Páginas
-
VIVALYTIC
30 Páginas
-
RANDOX DISCOVERY
36 Páginas
-
HbA1c
2 Páginas
-
technology at your fingertips
2 Páginas
-
RIQAS Troubleshooting checklist
1 Páginas
-
Preparing QC
1 Páginas
-
Point of Care Testing
12 Páginas
-
LT630 Monitoring EQA Performance
1 Páginas
-
LT394 Using QC Multirules
1 Páginas
-
Guide to running QC
1 Páginas
-
Tumour Marker Arrays
4 Páginas
-
Which QC is the Right QC
8 Páginas
-
How often is right for QC
6 Páginas
-
Cardiac Risk Multiplex Array
4 Páginas
-
Biochip Array Technology explained
12 Páginas
-
LT250 STI Multiplex Array NOV14
8 Páginas
-
LT241 Metabolic Array MAY15
8 Páginas
-
KRAS / BRAF / PIK3CA Array*
4 Páginas
-
Custom Arrays for Biochip
12 Páginas
-
LT169 Cardiac Array
4 Páginas
Catálogos arquivados
-
ACUSERA
108 Páginas
-
Evidence Evolution
28 Páginas
-
Evidence
16 Páginas
-
Metabolic Syndrome Arrays
8 Páginas
-
STI Multiplex Array
8 Páginas
-
Molecular Testing
16 Páginas
-
Evidence Investigator
20 Páginas
-
Fertility Array
4 Páginas
-
LT107 Evidence Investigator - 2014
20 Páginas
-
Rx Daytona
16 Páginas
-
Evidence Investigator
16 Páginas
-
Evidence
16 Páginas