RX MODENA A Fully Automated Clinical Chemistry Analyser CAPABLE OF PERFORMING UP TO 1200 TESTS PER HOUR
Abrir o catálogo na página 1
THE RX MODENA IS A FULLY AUTOMATED, CLINICAL CHEMISTRY ANALYSER, THAT PROMISES TO REVOLUTIONISE YOUR LABORATORY
Abrir o catálogo na página 2
SYSTEM OVERVIEW TEST MENU ORDERING INFORMATION RANDOX - A GLOBAL DIAGNOSTIC SOLUTIONS PROVIDER
Abrir o catálogo na página 3
BENEFITS The RX modena is a high throughput, floor standing clinical chemistry analyser, capable of performing up to 1200 tests per hour including ISE. With the ever expansive, unrivalled RX series test menu, the RX modena offers a winning combination for large multi-disciplinary laboratories. The icon based, interactive touch-screen technology offers an easy to use solution. The RX modena presents a new class of efficiency without compromising on the precision, reliability and accuracy that the RX series is famed for. TEST MENU TEST MENU & CONSOLIDATION ACCURATE RESULTS UNRIVALLED...
Abrir o catálogo na página 4
QUALITY CONTROL FLEXIBILITY & VERSATILITY COST SAVINGS Increased functionality Smart technology designed confidence in your results maximises testing capabilities to avoid additional costs Simple twice yearly preventative charts, calibration curves and QC can be generated via diffraction grating maintenance reduces the likelihood statistics for reliable results. ensuring a multitude of chemistries Users can view QC history. are possible on one system. Extensive test menu allows consolidation 7 different calibration options Continuous loading hatch allows of testing, and the ability to run...
Abrir o catálogo na página 5
SYSTEM OVERVIEW REAGENT CAROUSEL The RX modena reagent carousel has 100 cooled positions for 50x70ml & 50x20ml reagent bottles. An automatic barcode will identify the reagents added to the carousel which will be cooled between 8oC and 15oC to allow for a greater on-board stability. CUVETTES On-board the RX modena there are 153 semi-permanent cuvettes with a life span of 3-6 months. Cuvette check function ensures that only clean and viable reaction vessels are used. The user will be notified when cuvettes are required to be replaced. WASH STATION A 7 stage washing process includes acid,...
Abrir o catálogo na página 7
THE RX SERIES TEST MENU CLINICAL AUTOIMMUNE: Complement Component 3 Complement Component 4 CRP CRP Full Range (0.3-160mg/l) CRP High Sensitivity IgA IgE IgG IgM Rheumatoid Factor BASIC METABOLIC PROFILE: Calcium CO2 Total Chloride Creatinine Glucose Potassium Sodium Urea BONE PROFILE: Alkaline Phosphatase Calcium Phosphorus Total Protein CARDIAC: Cholesterol CK -MB CK-NAC CRP CRP Full Range (0.3 -160mg/l) CRP High Sensitivity Direct HDL Cholesterol Direct LDL Cholesterol Homocysteine Lipoprotein (a) sdLDL Triglycerides COMPREHENSIVE METABOLIC PROFILE: Albumin Alkaline Phosphatase ALT AST...
Abrir o catálogo na página 8
Albumin Alkaline Phosphatase ALT (GPT) Aldolase Ammonia Amylase AST (GOT) Bile Acids Bilirubin Calcium Chloride Cholesterol Cholinesterase (Butyryl) CK-NAC CO2 Total Copper Creatinine Canine CRP Fructosamine Gamma - GT GLDH Glucose Glycerol Iron (UIBC) Lactate Lactate Dehydrogenase LDL Lipase Magnesium NEFA (Non-Esterified Fatty Acids) Phosphorus (Inorganic) Potassium Ranbut (D-3-Hydroxybutyrate) Ransel (Glutathione Peroxidase) Ransod (Superoxide Dismutase) Sodium Total Protein Triglycerides Urea Uric Acid Urinary Protein Zinc THERAPEUTIC DRUGS: Phenobarbitol Valproic Acid DRUGS OF ABUSE:...
Abrir o catálogo na página 9
SOFTWARE The RX modena offers intuitive software through an interactive, Windows based touch screen display. This technology allows the user to easily navigate through the testing screens of the analyser, enabling easy access to information and control of operations from the main screen using informative tabs. Smart software automatically calculates remaining reagent volumes and the number of tests available, including their stability. The RX modena software is capable of connecting to LIMS (Laboratory Information Management System) via ASTM standard. CHEMISTRY PARAMETERS The operator can...
Abrir o catálogo na página 10
Maintenance on the RX modena is fast and effective. The run monitor displays full patient demographics. There are several simple steps to carry out daily, weekly and This screen indicates the number of tests and time left until monthly. Minimal daily maintenance is required. completion. The operator can add emergency STAT samples from this screen. QUALITY CONTROL The QC screen generates Levey-Jennings charts and The software displays the current valid calibration for each calibration curves, allowing for a visual performance assessment assay installed, the reagent blank absorbance (if...
Abrir o catálogo na página 11
Fully automated on-board haemolysis function for HbA1c testing Economic platform with water consumption of less than 20 litres per hour at peak usage Continuous loading hatch allows samples to be analysed quickly and 09 easily during each run Automatic wake up and sleep functionality including programmable daily maintenance 153 cuvettes on-board with cuvette check function Interactive touch-screen technology with Windows® based software
Abrir o catálogo na página 12
ORDERING & CUSTOMER SUPPORT In choosing to purchase the RX modena from Randox you are partnering with a company that has over 40 years’ experience in the IVD industry and clinical chemistry analyser placements in over 120 countries worldwide. Customers needs vary and Randox sales staff and distributor partners will work with your laboratory to create a bespoke package to suit your requirements. Randox Laboratories provide customers with an unrivalled technical support service. ORDERING INFORMATION RX modena analyser For more information contact your local representative, or email us at:...
Abrir o catálogo na página 13
SPECIFICATIONS PHYSICAL DIMENSIONS Height PERFORMANCE CHARACTERISTICS Throughput 1200 tests per hour including ISE 800 photometric tests per hour Analyser accreditation Analyser type Compact fully automated random access floor standing clinical analyser Assay types End point, 2 point end, rate, 2 point rate and ISE REAGENT & SAMPLE SYSTEM Reagent capacity 11 Reagent identification Reagent inventory Reagent pipette Removable tray with 100 cooled positions (50 positions for 70ml bottles and 50 positions for 20ml bottles) Automatic barcode reagent identification Calculation of remaining...
Abrir o catálogo na página 14Todos os catálogos e folhetos técnicos Randox Laboratories
-
LT735 Vivalytic Overview
32 Páginas
-
Acusera New Controls
8 Páginas
-
Acusera 24.7
24 Páginas
-
Acusera Third Party Controls
108 Páginas
-
Acusera SMART Controls
12 Páginas
-
Company Overview
40 Páginas
-
EDUCATIONAL GUIDE Gastroenteritis
12 Páginas
-
Superior Performance & Unique Tests
32 Páginas
-
Reagents Brochure
64 Páginas
-
sdLDL-C
8 Páginas
-
RX SERIES ANALYSER OVERVIEW
24 Páginas
-
RX misano
20 Páginas
-
RX Daytona Plus
20 Páginas
-
Rx Imola
20 Páginas
-
RX Monaco
20 Páginas
-
2024 Product List
64 Páginas
-
LT107 Evidence Investigator
32 Páginas
-
VeraSTAT-V
16 Páginas
-
LT033 RIQAS Explained
64 Páginas
-
VERASTAT
16 Páginas
-
Endocrine Array
4 Páginas
-
Cerebral Arrays
4 Páginas
-
Thyroid Arrays
4 Páginas
-
Respiratory Multiplex Array
8 Páginas
-
LT252 Respiratory Multiplex Array
8 Páginas
-
LT253 Molecular Diagnostics
20 Páginas
-
LT367 FH Array Brochure
4 Páginas
-
The role of EQA in QC
8 Páginas
-
Basic QC Stastics
8 Páginas
-
Commutability Guide
4 Páginas
-
How to measure uncertainty
8 Páginas
-
ISO 15189 Educational Guide
8 Páginas
-
Meeting ISO 15189 Requirements
4 Páginas
-
QC Multirules Educational Guide
8 Páginas
-
Troubleshooting QC Errors
8 Páginas
-
Qnostics
52 Páginas
-
Adiponectin LT519
28 Páginas
-
Specific Proteins
40 Páginas
-
Linearity sets
12 Páginas
-
Antioxidants
16 Páginas
-
Cardiology & Lipid Testing
28 Páginas
-
Diabetes Portfolio
28 Páginas
-
Total Bile Acids
4 Páginas
-
VIVALYTIC
30 Páginas
-
RANDOX DISCOVERY
36 Páginas
-
HbA1c
2 Páginas
-
technology at your fingertips
2 Páginas
-
RIQAS Troubleshooting checklist
1 Páginas
-
Preparing QC
1 Páginas
-
Point of Care Testing
12 Páginas
-
LT630 Monitoring EQA Performance
1 Páginas
-
LT394 Using QC Multirules
1 Páginas
-
Guide to running QC
1 Páginas
-
Tumour Marker Arrays
4 Páginas
-
Which QC is the Right QC
8 Páginas
-
How often is right for QC
6 Páginas
-
Cardiac Risk Multiplex Array
4 Páginas
-
Biochip Array Technology explained
12 Páginas
-
LT250 STI Multiplex Array NOV14
8 Páginas
-
LT241 Metabolic Array MAY15
8 Páginas
-
KRAS / BRAF / PIK3CA Array*
4 Páginas
-
Custom Arrays for Biochip
12 Páginas
-
LT169 Cardiac Array
4 Páginas
Catálogos arquivados
-
ACUSERA
108 Páginas
-
Evidence Evolution
28 Páginas
-
Evidence
16 Páginas
-
Metabolic Syndrome Arrays
8 Páginas
-
STI Multiplex Array
8 Páginas
-
Molecular Testing
16 Páginas
-
Evidence Investigator
20 Páginas
-
Fertility Array
4 Páginas
-
LT107 Evidence Investigator - 2014
20 Páginas
-
Rx Daytona
16 Páginas
-
Evidence Investigator
16 Páginas
-
Evidence
16 Páginas