
Grupo: Randox

Excertos do catálogo

SUPERIOR PERFORMANCE & UNIQUE TESTS DESIGNED TO MEET THE NEEDS OF YOUR LABORATORY 1
Abrir o catálogo na página 1
HIGH PERFORMANCE & UNIQUE TESTS Cardiology and Lipids | Diabetes | Renal Function | Antioxidants | Clinical Chemistry 2
Abrir o catálogo na página 2
RENAL FUNCTION CLINICAL CHEMISTRY UNIQUE FEATURE NICHE PRODUCT When you see this symbol you will know that this feature is unique to the Randox product When you see this symbol you will know that Randox have one of the only automated biochemistry assays available on the market
Abrir o catálogo na página 3
Benefits of Randox Reagents Randox offers an extensive range of third party diagnostic reagents which are internationally recognised as being of the highest quality; producing accurate and precise results. We have an extensive test menu of over 100 assays, covering over 100 disease markers including: antioxidants, diabetes, cardiology & lipid testing, specific proteins, therapeutic drug monitoring and veterinary testing. A wide range of formats and methods are available providing greater flexibility and choice for any laboratory size. In addition to flexible pack sizes and a comprehensive...
Abrir o catálogo na página 4
CARDIOLOGY & LIPIDS Lipoprotein (a) | Small Dense LDL Cholesterol (sdLDL - C) | Homocysteine Apolipoprotein C - II | Apolipoprotein C - III | Apolipoprotein E 02
Abrir o catálogo na página 5
Lipoprotein(a) (Lp(a)) Elevated levels of Lipoprotein(a) (Lp(a)), are considered to be both a causal risk factor and independent genetic marker of atherosclerotic disorders. The major challenge associated with Lp(a) measurement is the size variation of the apo(a) molecule within Lp(a). Dependent upon the size of the apo(a) in the assay calibrator, many assays under or overestimate apo(a) size in the patient sample. Numerous commercially available products suffer from apo(a) size related bias, resulting in an over estimation of Lp(a) in samples with large apo(a) molecules and an under...
Abrir o catálogo na página 6
Small - dense LDL (Low Density Lipoprotein) Cholesterol (sdLDL - C) Small - dense LDL Cholesterol (sdLDL - C) is a subtype of LDL cholesterol. All LDL transports triglycerides and cholesterol to bodily tissues but their atherogenicity varies according to size. Smaller particles such as sdLDL - C can permeate the inner arterial wall more readily and are more susceptible to oxidation, making sdLDL - C particularly atherogenic. Research has found that individuals with a predominance of sdLDL - C have a three - fold increased risk of myocardial infarction, making sdLDL - C measurement extremely...
Abrir o catálogo na página 7
Apolipoprotein C - II Apolipoprotein C - II (Apo C - II) is an amino acid protein synthesised mainly in the liver and to a lesser extent in the intestine. Apo C-II acts as a co - factor for lipoprotein lipase; an enzyme that hydrolyses triglycerides in chylomicrons and VLDL - C. Patients have been identified with hypertriglyceridemia due to a deficiency in Apo C - II which leads to an increased risk of the patient developing coronary artery disease. Additional disease states associated with Apo C - II deficiency include chylomicronemia, xanthomas and recurrent pancreatitis. S Indicates...
Abrir o catálogo na página 8
Apolipoprotein E Apolipoprotein E (Apo E) is an amino acid protein synthesised mainly in the liver but also in the brain, spleen, lungs, adrenals, ovaries, kidneys, muscle cells and in macrophages. The polymorphism of Apo E has been implicated in several diseases including cardiovascular disease and neurodegenerative diseases such as Alzheimer’s. Apo E deficiency causes high serum cholesterol and triglyceride levels and leads to premature atherosclerosis. A number of factors can affect Apo E concentrations including: genetic polymorphisms, oral contraceptive intake, puberty, BMI and age. S...
Abrir o catálogo na página 9
DIABETES Fructosamine | Non - Esterified Fatty Acids (NEFA) | D - 3 - Hydroxybutyrate (Ranbut) 07
Abrir o catálogo na página 10
(Glycated Serum Protein) Fructosamine is a mid - term indicator of diabetic control as it can provide information on a person’s average blood glucose levels over the preceding 14 - 21 days. After commencing therapy, fructosamine level decrease earlier (within a week) than HbA1c (after 4 - 8 weeks) and so, it is often used to evaluate the effectiveness of medication changes and to monitor the treatment of gestational diabetes. Fructosamine is also particularly useful in situations where HbA1c cannot be reliably measured when individuals have, for example: haemolytic anaemia, thalassemia or...
Abrir o catálogo na página 11
Randox D-3-Hydroxybutyrate (Ranbut) D - 3 - Hydroxybutyrate is the most sensitive ketone for the diagnosis of ketosis, in particular diabetic ketoacidosis. Ketosis, a metabolic process, occurs when the body switches from glucose to predominantly fat metabolism for energy production when carbohydrate availability reaches low levels. Metabolism of fatty acids in the liver results in the production of 3 ketones: acetone, acetoacetate and D - 3 - Hydroxybutyrate. Levels of ketone bodies in the blood are elevated (ketosis) when synthesis exceeds breakdown. Superior methodology when compared to...
Abrir o catálogo na página 12
RENAL FUNCTION Liquid Enzymatic Creatinine | Microalbumin 10
Abrir o catálogo na página 13
Liquid Enzymatic Creatinine Creatinine clearance in the kidneys provides a measure of the Glomerular Filtration Rate (GFR) and is the standard marker for renal function. The enzymatic method of Creatinine measurement displays several advantages over the JAFFE method: highly specific, no interferences from endogenous creatinine as it is not involved in the pathway and eliminates the requirement for urea determination. Systemic errors from JAFFE creatinine provides unreliable renal function estimates, resulting in the risk of incorrect drug dosage adjustments, misclassification in Chronic...
Abrir o catálogo na página 14
Microalbumin The Microalbumin assay detects very low levels of albumin in urine. The detection of albumin in urine can be an indicator of kidney injury which can result in irreversible damage if left untreated. Low albumin concentrations in urine (20 - 200mg/ day) is the earliest marker of renal damage and therefore enables preventative measures to be taken. Microalbumin testing can identify individuals with diabetic nephropathy approximately 5 - 10 years earlier than proteinuria tests helping reduce the incidence of end stage renal disease. Standard supplied with kit simplifying the...
Abrir o catálogo na página 15Todos os catálogos e folhetos técnicos Randox Laboratories
-
LT735 Vivalytic Overview
32 Páginas
-
Acusera New Controls
8 Páginas
-
Acusera 24.7
24 Páginas
-
Acusera Third Party Controls
108 Páginas
-
Acusera SMART Controls
12 Páginas
-
Company Overview
40 Páginas
-
EDUCATIONAL GUIDE Gastroenteritis
12 Páginas
-
Reagents Brochure
64 Páginas
-
sdLDL-C
8 Páginas
-
RX SERIES ANALYSER OVERVIEW
24 Páginas
-
RX modena
20 Páginas
-
RX misano
20 Páginas
-
RX Daytona Plus
20 Páginas
-
Rx Imola
20 Páginas
-
RX Monaco
20 Páginas
-
2024 Product List
64 Páginas
-
LT107 Evidence Investigator
32 Páginas
-
VeraSTAT-V
16 Páginas
-
LT033 RIQAS Explained
64 Páginas
-
VERASTAT
16 Páginas
-
Endocrine Array
4 Páginas
-
Cerebral Arrays
4 Páginas
-
Thyroid Arrays
4 Páginas
-
Respiratory Multiplex Array
8 Páginas
-
LT252 Respiratory Multiplex Array
8 Páginas
-
LT253 Molecular Diagnostics
20 Páginas
-
LT367 FH Array Brochure
4 Páginas
-
The role of EQA in QC
8 Páginas
-
Basic QC Stastics
8 Páginas
-
Commutability Guide
4 Páginas
-
How to measure uncertainty
8 Páginas
-
ISO 15189 Educational Guide
8 Páginas
-
Meeting ISO 15189 Requirements
4 Páginas
-
QC Multirules Educational Guide
8 Páginas
-
Troubleshooting QC Errors
8 Páginas
-
Qnostics
52 Páginas
-
Adiponectin LT519
28 Páginas
-
Specific Proteins
40 Páginas
-
Linearity sets
12 Páginas
-
Antioxidants
16 Páginas
-
Cardiology & Lipid Testing
28 Páginas
-
Diabetes Portfolio
28 Páginas
-
Total Bile Acids
4 Páginas
-
VIVALYTIC
30 Páginas
-
RANDOX DISCOVERY
36 Páginas
-
HbA1c
2 Páginas
-
technology at your fingertips
2 Páginas
-
RIQAS Troubleshooting checklist
1 Páginas
-
Preparing QC
1 Páginas
-
Point of Care Testing
12 Páginas
-
LT630 Monitoring EQA Performance
1 Páginas
-
LT394 Using QC Multirules
1 Páginas
-
Guide to running QC
1 Páginas
-
Tumour Marker Arrays
4 Páginas
-
Which QC is the Right QC
8 Páginas
-
How often is right for QC
6 Páginas
-
Cardiac Risk Multiplex Array
4 Páginas
-
Biochip Array Technology explained
12 Páginas
-
LT250 STI Multiplex Array NOV14
8 Páginas
-
LT241 Metabolic Array MAY15
8 Páginas
-
KRAS / BRAF / PIK3CA Array*
4 Páginas
-
Custom Arrays for Biochip
12 Páginas
-
LT169 Cardiac Array
4 Páginas
Catálogos arquivados
-
ACUSERA
108 Páginas
-
Evidence Evolution
28 Páginas
-
Evidence
16 Páginas
-
Metabolic Syndrome Arrays
8 Páginas
-
STI Multiplex Array
8 Páginas
-
Molecular Testing
16 Páginas
-
Evidence Investigator
20 Páginas
-
Fertility Array
4 Páginas
-
LT107 Evidence Investigator - 2014
20 Páginas
-
Rx Daytona
16 Páginas
-
Evidence Investigator
16 Páginas
-
Evidence
16 Páginas