2019 VeriLinkRx
1 / 4Páginas

{{requestButtons}}

Excertos do catálogo

2019 VeriLinkRx - 1

TPN, COMPOUNDING AND DRUG DIVERSION SYSTEM. Close the broken link in your narcotics chain of custody program Validate Fentanyl with VeriLinkRx

Abrir o catálogo na página 1
2019 VeriLinkRx - 2

Do you know what is in your syringe? • Diversion is a problem, because 15% of healthcare professionals struggle with drug dependence at some point in their career contributing to the drug diversion problem. • Testing narcotics returned to the hospital pharmacy with the VeriLinkRx alerts staff to tampered or sub-therapeutic dosage levels. ® • The VeriLinkRx can be used to test Morphine, Hydromorphone, Fentanyl, and other narcotics e.g. hundreds of injectable solutions have been tested and added to the system library. ® • Standard existing chain of custody control measures like biometric...

Abrir o catálogo na página 2
2019 VeriLinkRx - 3

Why $200 - $ 1,000 hand held refractometers don’t work? Handheld refractometers are performance limited because their inexpensive components drift and fluctuate with temperature and sample conditions. Handheld refractometers work fine to differentiate between a 10° and 11° Brix food product, but they do not have the refractive index accuracy and temperature control stability to distinguish the Refractive Index difference between substances such as Fentanyl and water. The VeriLinkRx was developed by Rudolph using technology predicated on rigorous pharmaceutical standards such as USP<831>. To...

Abrir o catálogo na página 3
2019 VeriLinkRx - 4

VeriLinkRx tests proprietary formulations for Compounding and TPN. ® Concentration Fentanyl Saline ug/ml 50 The VeriLinkRx tests the quality of formulations and verifies the ingredients are 40 mixed properly. For example, the VeriLinkRx can validate if a dextrose or insulin conµg/mL centration is mixed too high or low. The VeriLinkRx can also be used 30 special drug for 20 formulations in Children Hospitals such as Fentanyl to verify it is mixed properly in low 10 dosages. An example for the Fentanyl calibrations is shown below, and the system comes 0 pre-calibrated for special formulations...

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos Rudolph Research Analytical

  1. AutoFlex ® R837

    8 Páginas

  2. Alcotest® RI

    6 Páginas

  3. The Autopol® IV

    6 Páginas

  4. The Autopol® III

    2 Páginas

  5. The Autopol® II

    2 Páginas

  6. The Autopol® I

    2 Páginas

  7. Autopol ® V PLUS

    4 Páginas

  8. AutoPol

    6 Páginas

  9. AutoFlex R837

    4 Páginas

  10. AutoFill

    4 Páginas

  11. ECS

    2 Páginas

  12. VeriLinkRx

    4 Páginas

Catálogos arquivados