What is Transcranial Electrical Stimulation? 产品介绍 Transcranial Electrical Stimulation (tEs) is a non-invasive neurostimulation technique that applies a specific, low-intensity current (usually 0-2 mA) to specific brain regions through electrodes to modulate neural activity in the cerebral cortex. the goal of. This technique includes a variety of stimulation methods, which can be divided into: Transcranial Direct Current Stimulation (tDCS) Transcranial Alternating Current Stimulation (tACS) 恒稳直流电 Transcranial Random Noise Stimulation (tRNS) Transcranial pulsed current Stimulation (tPCS)...

Abrir o catálogo na página 2
TDCS-02 - 3

What is the difference between transcranial direct current stimulation 产品介绍 适用范围 and transcranial magnetic stimulation? pTranscranial Magnetic Stimulation(TMS) * Suprathreshold stimulation; * Generate action potentials, causing neurons to fire; * Brain stimulation technology. pTranscranial direct current stimulation(tDCS) * Subthreshold stimulus; * Acts by modulating resting membrane potential, modulating spontaneous neuronal network activity; * Neuromodulat

Abrir o catálogo na página 3
TDCS-02 - 4

Product Description E-TDCS Transcranial Electrical Stimulator Transcranial electrical stimulator is a non-invasive technology that uses constant, low-intensity current (0-2mA) to modulate nerves. The current is delivered to the designated brain area through electrodes, and the intracranial current will increase or decrease the neuron cell's activation. Excitability (depending on the polarity of the electrodes), increased or decreased excitability can cause changes in brain function that can be used to treat diseases or study brain function. It has been widely used in clinical work because...

Abrir o catálogo na página 4
TDCS-02 - 5

Effect on cerebral blood flow适用范围 产品介绍 基本配置 Anodal stimulation induced a large increase (17.1%) in rCBF during stimulation, which returned to baseline after the current was turned off, but exhibited an increase in rCBF again in the post-stimulation period. Cathodal stimulation induced a smaller increase (5.6%) during stimulation, a significant decrease compared to baseline (−6.5%) after cessation, and a continued d

Abrir o catálogo na página 5
TDCS-02 - 7

The longer the stimulation time, the more obvious the follow-up effect Duration

Abrir o catálogo na página 7
TDCS-02 - 8

Stimulation depth of tDCS Thalamus Dorsal brain stem Toralf Neuling 1 † , Sven Wagner 2 † , Carsten H. Wolters .Finite-element model predicts current density distribution for clinical applications of tDCS and tACS. ORIGINAL RESEARCH ARTICLE published: 24 Sep

Abrir o catálogo na página 8
TDCS-02 - 9

Structural form Handheld Total number of channels Single group of 2 channels Operation mode Button Dual groups of channels (with 2 channels or high precision 5 channels multiple stimulation modes) Touch screen Eight groups of channels (with 2-channel or high-precision 5channel multiple stimulation modes) Management system 19 inch monito

Abrir o catálogo na página 9
TDCS-02 - 10

Application This product is suitable for the treatment of motor dysfunction, language cognitive impairment, and swallowing disorders caused by brain injury. Application field Ø Rehabilitation of neurological and psychiatric diseases: movement disorders, balance disorders, cognitive disorders, speech and language disorders, visual perception disorders, disorders of consciousness, dystonia, etc. caused by brain injury, spinal cord injury, epilepsy, insomnia, depression, anxiety disorders , schizophrenia, stroke, aphasia, etc. Ø Rehabilitation of children: children with cerebral palsy, autism,...

Abrir o catálogo na página 10
TDCS-02 - 11

Contraindications and people with caution 产品介绍 Those with metal implants in the body; metal materials (including MRI-compatible materials such as titanium metal), arterial clips, etc.; ü Those with implanted devices in the body: pacemakers, deep brain stimulators (DBS); ü patients with metal implants; Intracranial hypertension, skull defect, tumor patients; ü malignant tumor patients; Serious heart disease, physical disease and other unstable vital signs; acute phase of cerebrovascular disease; ü pregnant women and children; Those who have adverse reactions to electrical stimulation;...

Abrir o catálogo na página 11
TDCS-02 - 12

Five treatment modes产品介绍 for a wider range of treatments 基本配置 适用范围 tDCS(transcranial Direct Current Stimulation) tACS(transcranial alternating current Stimulation) tPCS(transcranial pulsed current Stimulation) tRNS(transcranial Random Noise Stimulation) CES(Cranial Electrotherapy

Abrir o catálogo na página 12
TDCS-02 - 13

Multiple stimulus output modes Stimulus output mode 1) 2-channel output (anode/cathode): a two-channel stimulation method of one yin and one yang is adopted, and the output of the stimulation type is set by the control software, which acts on the cerebral cortex with weakly polarized direct current. 2) 5-channel output (high-precision output: one yang and four yin or one yin and four yang): It integrates the low-intensity, safety and breakthrough high-precision target control technology of traditional tDCS, which greatly improves the focus of tDCS High-precision tDCS produces neuroplastic...

Abrir o catálogo na página 13
TDCS-02 - 14

Safe, non-invasive & long-lasting Safe and non-invasive: Transcranial electrical stimulation uses an auxiliary fixation device to fix the head electrodes. It is a non-invasive technology that uses low-intensity current to regulate neuronal activity in the cerebral cortex without causing any trauma. At the same time, the relevant safety literature shows that: Transcranial electrical stimulation does not induce or cause other risks of brain injury. Precise control: The output current intensity is four gears: 0-0.5mA, 0-1mA, 0-1.5mA, 02mA, and the adjustment range is 0-255 levels. The output...

Abrir o catálogo na página 14
TDCS-02 - 15

Clinical application - how to operate 1. The stimulation effect is determined by the stimulation site, the intensity of the current, the area and polarity of the electrode pads; Assessment + Imaging - Stimulation Site - Stimulation Method - Current Strength - Start Treatment 2. Stimulation method: Anodal stimulation: the anode electrode is placed in the target brain area, excited; Cathodal stimulation: The cathode electrode is placed in the target brain area, inhibiting; Pre-stimulation: During the stimulation process, the current rises to the predetermined current and then drops to 0; the...

Abrir o catálogo na página 15

Todos os catálogos e folhetos técnicos Shanghai Goodmed Medical Device

  1. AIR902

    1 Páginas

  2. XY-K-JLC-D

    3 Páginas

  3. S610

    2 Páginas

  4. S400

    2 Páginas

  5. S110

    1 Páginas

  6. OM-A-ECP1 EECP

    1 Páginas

  7. OM-A-II ECP

    1 Páginas

  8. OM-A ECP

    4 Páginas

  9. GD-FA

    9 Páginas

  10. HB102

    1 Páginas

  11. HB101

    1 Páginas

  12. HB100

    1 Páginas

  13. HB-400W

    1 Páginas

  14. HB-200W

    1 Páginas

  15. AMT-B

    24 Páginas

  16. RTM06

    2 Páginas

  17. RTM05

    2 Páginas

  18. RTM04

    2 Páginas

  19. RTM03

    2 Páginas

  20. RTM02

    2 Páginas

  21. HB510B rtms

    7 Páginas

  22. Smart Tecar

    9 Páginas

  23. PMST-4 NEO 2 in 1

    5 Páginas

  24. WB003

    84 Páginas

  25. SWT300

    2 Páginas

  26. Ruilex

    1 Páginas

  27. XY-CJB-II

    6 Páginas

  28. HBY-FL15

    9 Páginas

  29. HBY-FL20

    9 Páginas

  30. 4500U1

    9 Páginas

  31. S720

    1 Páginas

  32. S530

    1 Páginas

  33. S500

    1 Páginas

  34. WB-W-E

    6 Páginas

  35. AMT-C

    24 Páginas

  36. HB-200C

    1 Páginas

  37. TMS

    14 Páginas

  38. MAGREX-A

    2 Páginas

  39. PMST-3

    5 Páginas

  40. R02

    13 Páginas

  41. RTM01

    2 Páginas

  42. ZP4

    1 Páginas

  43. SJ1

    1 Páginas

  44. HB520B rtms

    7 Páginas

  45. RT1100

    14 Páginas