IG-1000 Plus
1 / 16Páginas

{{requestButtons}}

Excertos do catálogo

IG-1000 Plus - 1

Single Nano Particle Size Analyzer

Abrir o catálogo na página 1
IG-1000 Plus - 2

Voyaging into the Single Nano Region

Abrir o catálogo na página 2
IG-1000 Plus - 3

I G- 100 0 P lus Si ngl e N a n o P a r t i c l e S i z e An a ly ze r High-Sensitivity Analysis of Single Nano Particles The IG-1000 Plus measures optical signals from a diffraction grating formed by the particles, rather than scattered light being emitted by the particles. This means that even in the single nano region, a sufficient S/N ratio can be obtained and stable measurement with good reproducibility is possible. In addition, the IG-1000 Plus can achieve a sensitivity 10 times higher than the IG-1000. Resistance to Contamination The new measurement principle is resistant to...

Abrir o catálogo na página 3
IG-1000 Plus - 5

Beyond the Single Nano Region and Into the Sub-Nano Region The IG-1000 Plus Single Nano Particle Size Analyzer The IG-1000 Plus uses the induced grating (IG) method, which is based on a new principle for measuring the size of nano particles using the phenomenon of dielectrophoresis and diffracted light. The conventional method measures the light scattered by particles, but this decreases sharply for particle sizes of less than 100 nm. Furthermore, in the single nano region (i.e. particle sizes of less than 10 nm), there are physical restrictions that make it difficult to detect scattered...

Abrir o catálogo na página 5
IG-1000 Plus - 6

Measurement Data Examples M eas ur eme n t o f P i g m e n t ed In k Na n o P a rticle s Nano particles tend to aggregate easily, but when they are used as pigmented inks it is important that they remain in a well-dispersed state for a long period of time without aggregating or precipitating. It is difficult for light to pass through highly-absorbent particles. With a short optical path cell (special accessory), which decreases the absorption of samples, the IG-1000 Plus overcomes this restriction, making it a powerful tool for quality control in the ink and paint industries. Particle size...

Abrir o catálogo na página 6
IG-1000 Plus - 7

M eas ur em e n t o f N a n o P a rticle s in S u n scre e n Ultrafine particles (nano particles) such as titanium oxide or zinc oxide are used in sunscreen to block exposure to ultraviolet rays. The use of such nano particles reduces the scattering of visible light rays, resulting in sunscreens with high transparency that do not turn white upon application. Titanium Oxide Nano particles may easily aggregate to form larger particles, which increase the amount of scattered light, resulting in the loss of transparency. Therefore, it is important that the nano particles are kept in a...

Abrir o catálogo na página 7
IG-1000 Plus - 8

F ur t her D a t a E x a m p l e s The following data was obtained by analyzing various sample particle groups of various sizes with the IG-1000 Plus. Fullerene hydroxide, an example of a substance in the single nano region, can be analyzed with high reproducibility. Particle Size Distribution (Volumetric Basis) Normalized Particle Amount Fullerene Hydroxide Particle Diameter (nm) (Sample provided by Prof. Kokubo of Osaka University) Even with samples containing a wide range of particle sizes, there is no bias toward larger particles, and the existence of smaller particles is accurately...

Abrir o catálogo na página 8
IG-1000 Plus - 9

Anal ys i s o f Mi x e d S a m p l es With methods based on scattered light, even if the volume is the same, the signal size is proportional to the cube of the particle diameter, making evaluation of mixed samples difficult. The IG method uses the diffusion of the diffraction grating created by particles; therefore, the signal size does not depend on the particle size, allowing the analysis of mixed samples. Particle Size Distribution (Volumetric Basis) Normalized Particle Amount Colloidal silica Particle Size Distribution (Volumetric Basis) Normalized Particle Amount Polystyrene latex...

Abrir o catálogo na página 9
IG-1000 Plus - 10

The Science Behind the Clarity What I s t h e " I n d u c e d G r a tin g Me th o d " ? A periodic concentration distribution of particles formed in a medium by an external force functions as a diffraction grating. When the external force is removed, the particles spread out and the diffraction grating disappears. The IG method measures the decay of the particle density diffraction grating through changes in intensity of the diffracted light, and determines the diffusion coefficient. Batch cell Semiconductor laser Condensing lens Optical detector Intensity of diffracted light Large...

Abrir o catálogo na página 10
IG-1000 Plus - 11

Diffraction Grating Formed by Dielectrophoresis An alternating voltage is applied to cyclically arranged electrodes, and a cyclic concentration distribution of microscopic particles is formed in the liquid by dielectrophoresis. Although the cyclic concentration distribution of microscopic particles acts as a diffraction grating, if the alternating voltage is stopped, the grating diffuses and disappears (Patent No. 4375576). Optical detector Diffracted light created by particles Diffracted light created by electrodes Optical detector -Precision Measurement By Changing Electrode...

Abrir o catálogo na página 11
IG-1000 Plus - 12

Powerful Measurement Functions A ppl yi ng A t t e n u a t i o n D a ta In addition to the measurement results for particle size distributions, data on changes in the intensity of diffracted light (i.e. attenuation) can also be used. This data can be output to Excel, allowing users to try out their own analytical techniques. Validate Results Using Attenuation Data If the particles are small, the attenuation gradient is high, whereas if the particles are large, the attenuation gradient is small. This means that the relative (average) sizes of particles can be ascertained at a glance....

Abrir o catálogo na página 12
IG-1000 Plus - 13

Check Measurement Conditions With Intensity Data It is necessary to set the parameters below. Application duration: 10 to 1,000 ms Applied voltage: 5 to 35 Vpp Frequency: 1 kHz to 1 MHz If the maximum intensity of the diffracted light is between these two lines, the measurement conditions are appropriate. It is possible to check whether or not these are the optimum measurement conditions using the optical intensity level and the upper and lower limit lines displayed on the screen. Relative Light Intensity Diffracted Light Intensity Check Diffusion Time (msec) I np u t Sam ple In Thr ee Si m...

Abrir o catálogo na página 13

Todos os catálogos e folhetos técnicos Shimadzu

  1. RADspeed Pro EDGE

    5 Páginas

  2. UV-1900i

    4 Páginas

  3. LCMS-9030

    12 Páginas

  4. LCMS-8050

    20 Páginas

  5. LCMS-8045

    12 Páginas

  6. XRD-6100

    32 Páginas

  7. EDX-LE

    16 Páginas

  8. PDA-8000

    16 Páginas

  9. AA-6200

    12 Páginas

  10. UV-3600i Plus

    20 Páginas

  11. SPM-9700HT

    27 Páginas

  12. SALD-2300

    20 Páginas

  13. MB140

    4 Páginas

  14. ATX/ATY Series

    6 Páginas

  15. MOC63u

    2 Páginas

  16. MOC-120H

    4 Páginas

  17. MOC63u

    8 Páginas

  18. UW/UX Series

    4 Páginas

  19. New products 1

    1 Páginas

  20. New products

    1 Páginas

  21. BL series

    2 Páginas

  22. BW-K/BX-K

    2 Páginas

  23. TX/TXB/TXC Series

    8 Páginas

  24. HMV- 2 brochure

    8 Páginas

  25. Solutions Brochure

    24 Páginas

  26. PSSM - 8 System

    8 Páginas

  27. MOC-120H

    4 Páginas

Catálogos arquivados

  1. MOC63U Flyer

    2 Páginas

  2. UW/UX Series

    4 Páginas

  3. SALD-7101

    16 Páginas

  4. MOC63U

    6 Páginas