2SC General Specifications
1 / 2Páginas

Excertos do catálogo

2SC General Specifications - 1

GENERAL SPECIFICATIONS 2 BODY, MORGUE COOLER, SIDE OPENING EXTERIOR - FRONT: 20 GA. (.91mm) TYPE 304 POLISHED STAINLESS STEEL, #4 FINISH SIDES, BACK, TOP: .032" (.81mm) STUCCO EMBOSSED ALUMINUM INTERIOR - WALLS, CEILING: .032" (.81mm) STUCCO EMBOSSED ALUMINUM DOOR: 20 GA. (.91mm) TYPE 304 STAINLESS STEEL, #4 FINISH FLOOR: 20GA (.91mm) GALVANIZED STEEL INSULATION - NOMINAL 4" (102mm) FOAMED IN PLACE POLYURETHANE INSULATION DOOR HEATERS - PERIMETER ANTI-SWEAT DEVICE, REPLACEABLE, HARDWARE - ADJUSTABLE, EDGEMOUNT TYPE, CHROME PLATED; EDGE MOUNTED KEYED LATCH; CARD HOLDER(S) GASKET - EXTRUDED VINYL, WELDED CORNERS, DART STYLE, REPLACEABLE CARRIAGE & FRAME - DOOR MOUNTED ROLLER FRAME, STAINLESS STEEL, ZINC PLATED BALL BEARING ROLLERS REMOVABLE TRAYS - QUANTITY 2, MT1 16 GA. (1.5mm) TYPE 304 POLISHED STAINLESS STEEL CONDENSING UNIT - DROP IN, SELF CONTAINED (TOP MOUNT), INDOOR REFRIGERATION SYSTEM; DESIGN LOAD OF 5,183 BTUH AT 95°F (35°C) AMBIENT TEMPERATURE AND 35°F (2°C) BOX TEMPERATURE; R-404A REFRIGERANT; OFF CYCLE DEFROST TIMER; 115 VOLTS/60 HERTZ/1 PHASE ELECTRICAL, 14.5 UNIT AMPS, PSC TYPE MOTORS ON CONDENSING UNIT WITH EC TYPE MOTORS ON EVAPORATOR; SYSTEM IS FACTORY-ASSEMBLED, EVACUATED, CHARGED, AND RUN TESTED DIGITAL TEMPERATURE READOUT SECTIONAL CONSTRUCTION SHIPPED ASSEMBLED UNLESS OTHERWISE SPECIFIED SHIPPING WEIGHT -1,550 LB. (703 KG.) APPROXIMATELY AVAILABLE OPTIONS: □ LIGHTING FIXTURE WITH PILOT SWITCH □ STAINLESS STEEL INTERIOR □ STAINLESS STEEL EXTERIOR □ STAINLESS STEEL TRIM ENCLOSURE PANELS □ ROLLER FRAME TRAY RAILS WITH ANTI-TILT FOR CSI/JEWETT BODY TRANSPORT SYSTEMS □ MODEL DTPM TEMPERATURE AND POWER MONITORING SYSTEM □ MODEL 7ER CIRCULAR SEVEN DAY CHART RECORDER □ CONTACT CSI/JEWETT FOR CUSTOM SPECIFICATIONS OR OPTIONS

Abrir o catálogo na página 1
2SC General Specifications - 2

PLAN VIEW CONDENSING UNIT PACKAGE SYSTEM FRONT ELEVATION SIDE ELEVATION 1. (1) 115 VOLTS/60 HERTZ/1 PHASE, 15 AMP CIRCUIT FOR DOOR HEATERS, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL REGULATIONS. PROVIDE THE ABOVE REQUIREMENTS TO AN AREA ABOVE THE REFRIGERATOR AND WITHIN 5'-0" OF DESIGNATED AREA ON DRAWING. 2. (1) 115 VOLTS/ 60 HERTZ/1 PHASE, 20 AMP CIRCUIT FOR CONDENSING UNIT, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL REGULATIONS....

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos Spire Integrated Solutions

  1. CWC Series

    4 Páginas

  2. STERIPLUS™ 40

    2 Páginas

  3. Tesalys

    8 Páginas

  4. Model DPEM

    2 Páginas

  5. Medicine Station

    2 Páginas

  6. MC2-B-MT1

    2 Páginas

  7. Model DPV

    2 Páginas

  8. DP AUTOPSY TABLE

    2 Páginas

  9. R1910-31L/R

    2 Páginas

  10. SR1910-30

    2 Páginas

  11. REMOTE MORGUE

    2 Páginas

  12. 6R2W SPECS

    2 Páginas

  13. 4R2W Specs

    2 Páginas

  14. 3R1W SUBMITTAL

    1 Páginas

  15. 2R1W SUBMITTAL

    1 Páginas

  16. 1R SUBMITTAL

    1 Páginas