Grupo: Telic Group
Excertos do catálogo

Technical data sheet The product consists on the active electrode to be connected into the tip of the electrosurgical pencil. C€ 0197 Product charasteristics • Sterile by Ethylene Oxide. • Shelf life: 4 years upon the manufacturing date Technical specifications H Materials • Electrode: Stainless Steel • Electrode tip: Tungsten . Tube: PTFE . Tube: Blue PVC • Pouch: • Cellulose, medical grade . PET/PE Film B Main dimensional properties This document is the property of Telic, S.A.U. Transmission to third-parties or non-authorized copies are not allowed 1 - 3
Abrir o catálogo na página 1
Technical data sheet B Other properties • Requirements established by electrical safety standard IEC 60601-2-2 are met. • Disposable tungsten electrodes are compatible with all references of Blayco electrosurgical pencils. Biocompatibility • ISO 10993-5: No cytotoxic. • ISO 10993-10: No sensitizing. • ISO 10993-10: Negative intracutaneous irritation test. • Conclusion: product is biocompatible. B Storage and maintenance • Keep protected from direct sunlight / the outside. • Keep in a dry place. • Temperature range: -20°C - 60°C • Single use product. No maintenance required. B Packaging #...
Abrir o catálogo na página 2
Technical data sheet • BLAYCO Electrosurgical Accessories are designed for use with BLAYCO Electrosurgical Pencils. Prior to use, carefully read the manufacturer instructions on how to operate the electrosurgical unit and accessories. • Visually examine the package for damages before opening. Replace the product in case that the package or the electrode tip itself shows signs of damage. • Check the production and expiry date printed on the package. In case that the product is expired, replace by a backup device within expire date. • Open the package using aseptic technique. • Operate...
Abrir o catálogo na página 3Todos os catálogos e folhetos técnicos Telic
-
Defibrillation electrodes adults
5 Páginas
-
CUp Electrodes
3 Páginas
-
Disposable electrode tip cleaner
2 Páginas
-
ECG electrodes for neonatal patients
2 Páginas
-
Surface electrodes
2 Páginas
-
Concentric needles
2 Páginas
-
Corkscrew subdermal needles
2 Páginas
-
Conductive gel
3 Páginas
-
Telic Groupe
27 Páginas
-
Blayco dermal curette
2 Páginas
-
Blayco biopsy punches
3 Páginas
-
Dormo electrodes for neurophysiology
11 Páginas
-
Blayco-Pad
2 Páginas
-
Skin marker
2 Páginas
-
Lubricating water soluble gel
2 Páginas
-
Nasal holder for gastric catheters
2 Páginas
-
Cover for surgical light handle
2 Páginas
-
Desfi-Dormo ED-1010
3 Páginas
-
G-15/1 Ultrasound transmission gel
3 Páginas
-
Dormo-Strip
3 Páginas