

Excertos do catálogo

Bonded Silica-Based Columns for HPLC Thermo Scientific brand
Abrir o catálogo na página 1
Ordering and Warranty Information In the U.S. Acclaim 120 Acclaim 300 Acclaim PA/PA2 Acclaim OA All Orders Including: • Credit Card Orders (VISA, American Express, MasterCard) • Blanket Orders • Emergency Orders Call 1-800-Dionex-0 (1-800-346-6390) or Acclaim 120 Acclaim PA Acclaim Explosives FAX 1-408-736-4476 Ordering by Credit Card Dionex accepts payment by MasterCard, VISA, and American Express cards with minimum orders of $50.00. Call 1-800-DIONEX-0 (1-800-346-6390) for more information. Blanket Orders Acclaim OA Acclaim PA/PA2 Acclaim 120 Dionex will arrange for blanket orders with a...
Abrir o catálogo na página 2
Introduction INTRODUCTION Par I: Introduction t Acclaim Column Families at a Glance Dionex Acclaim columns are silica-based columns designed for high efficiency separations and manufactured using ultra-high purity silica. Product families consists of a broad spectrum of stationary phases in the form of the conventional C8 and C18 phases. polar embedded phases. and several specialty phases, each designed for a specific application or group of applications. All Acclaim columns are designed and manufactured at Dionex, to tight specifications, to ensure consistent performance. General Purpose...
Abrir o catálogo na página 4
Dionex phase Bonded phase Ultrapure silica Ultrapure silica Ultrapure silica Ultrapure silica Ultrapure silica Particle shape Particle size Average pore diameter Total carbon content Acclaim General Purpose Column Specifications Acclaim Specialty Column Specifications Specialty HPLC Columns Dionex phase Acclaim Surfactant Bonded phase na na Specialty column for fast organic acid analysis Yes Yes Endcapped Substrate Particle shape Particle size The Acclaim OA column features a patented polar-embedded stationary phase optimized and use tested for hydrophilic Ultrapure silica Ultrapure OA...
Abrir o catálogo na página 5
Introduction INTRODUCTION Selecting an Acclaim Column There are four questions to consider when choosing an HPLC column: 1. What are the goals of the separation? • Speed of analysis • Critical peaks requiring resolution strongly hydrophobic molecules and this will be the only retention mechanism. As the density of the bonded phase decreases, other retention mechanisms will come into play, such as ion exchange interactions between the sample and residual silanol groups on the surface of the silica gel, or sieving effects for similar sized molecules of different shapes. Thus, these studies...
Abrir o catálogo na página 6
Introduction INTRODUCTION Acclaim Selectivity Column: Mobile Phase: Temperature: Flow Rate: 4.6 × 150 mm 49/51 w/w methanol/phosphate buffer, pH 7.0 40 °C 1 mL/min Column: Mobile Phase: Temperature: Flow Rate: Ethyl benzoate Dimethylaniline 0.4 Phenol Aniline Pyridine Retention Time Relative to Toluene Relative Retention Time vs Toluene o-Terphenyl 2 Ethylbenzene Toluene Hydrophobic Compounds Probe Molecules Property Indicator Hydrophobic interaction Selectivity for molecular shape Phenol, aniline and pyridine Dipole-dipole interactions and hydrogen bonding Choosing the Appropriate Particle...
Abrir o catálogo na página 7
Introduction INTRODUCTION Understanding More about the Bonded Phase Column Diameter Dionex offers highest quality silica-based reversed phase packing materials. The type of bonding, carbon load and endcapping are all factors that contribute to the superior bonded phase. Type of Bonding Functional groups are attached to the silica substrate either via a single attachment (monomeric bonding), or via multiple attachments (multidentate bonding). Monomeric bonded phases provide higher column efficiencies, than polymeric phases, but polymeric phases are very stable under pH extremes. Select a...
Abrir o catálogo na página 8
The effect of mobile phase composition on column lifetime should be part of the consideration for designing a method. Use the highest practical quality of water, solvent, and buffer components; HPLC-grade material has low UV absorbance and is submicron-filtered by the manufacturer. To prevent fouling of your Acclaim column, use mobile phases that have been filtered through a 0.5-µm or smaller filter. Both alkaline conditions and strong acid conditions will degrade silica-based columns over time. The silica substrate resists acids, but is soluble in alkali. The upper pH limit is determined...
Abrir o catálogo na página 9
Introduction INTRODUCTION Acclaim Columns Dedicated to High Quality Base Asymmetry Acclaim Columns Base Performance: Amitriptyline Reliability and Durability At Dionex we know that quality and reliability are essential to a successful analysis. Our columns are thoroughly tested individually, so that chromatographers can have full confidence in them. Manufacturing starts with an ultrapure silica substrate, using only carefully selected lots with narrow ranges of physical parameters. By design, the bonding processes are clean and repeatable with no unexpected changes in performance. Each...
Abrir o catálogo na página 10
Introduction Steric Selectivity Evaluation of Metal Contamination Column: Dimensions: Mobile Phase: Temperature: Flow Rate: Comparison of Steric Selectivity for Acclaim 120 C18 and Acclaim PA Acclaim 300 C18, 3 µm 4.6 × 150 mm 50/50 v/v water/methanol 30 °C 1.0 mL/min Columns: Mobile Phase: Temperature: Flow Rate: Inj. Volume: 1. Toluene 2. Phenanthrene 3. o-Terphenyl 4. Triphenylene Column: Dimensions: Mobile Phase: Temperature: Flow Rate: Inj. Volume: Detection: As indicated 90% methanol 30 °C 1 mL/min 5 µL Metal Contamination Peaks: 1. Toluene 2. Phenanthrene 3. o–Terphenyl 4....
Abrir o catálogo na página 11
Performance Specifications Polar selectivity ratio Base asymmetry High performance reversed-phase columns for the separation of small molecules Metal activity ratio Steric selectivity ratio Retention time Chromatographic specifications for Acclaim 120 C18 4.6 × 150 mm columns. Please refer to Part 4 for a detailed description of the tests and specifications. Specifications are subject to change at the discretion of Dionex. The Acclaim 120 C18 series columns feature a densely bonded monolayer of octadecyldimethylsiloxane on a highly pure, spherical, silica substrate with 120 Å pore...
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos Thermo Scientific
-
CryoStar NX50
2 Páginas
-
Precise sections – perfectly simple
6 Páginas
-
MSC-Advantage BSC
54 Páginas
-
Multifuge
58 Páginas
-
Sorvall WX+ Ultracentrifuge Series
8 Páginas
-
Thermo Scientific Pico 17 / 21
52 Páginas
-
Forma Series II Water Jacket CO2 Incubator
104 Páginas
-
CO2 Incubator HERAcell 150 i / 240 i
196 Páginas
-
Revco® Blood Bank Refrigerators
37 Páginas
-
Multidrop Combi nL
4 Páginas
-
Forma Environmental Chambers
25 Páginas
-
MaxQ 6000
40 Páginas
-
Multi Tube Rotator
13 Páginas
-
picoSpin Spectrometer
6 Páginas
-
1300 Series A2
76 Páginas
-
CO2 Incubator Family
28 Páginas
-
CO2 incubators
7 Páginas
-
Series 8000 Direct-Heat CO2 Incubators
84 Páginas
-
MaxQ Mini 4450 Shaker
40 Páginas
-
E1-ClipTip Electronic Pipette
108 Páginas
-
Varioskan™ LUX
54 Páginas
-
Spinnaker Advanced Benchtop Robot
2 Páginas
-
ISQ Series Mass Spectrometers
412 Páginas
-
Thermo Scientific GasBench II
8 Páginas
-
Q Exactive™ BioPharma
16 Páginas
-
Q Exactive Plus
4 Páginas
-
LTQ XL™
4 Páginas
-
Thermo Scientific Exactive Plus
4 Páginas
-
Platinum DNA polymerases
6 Páginas
-
-80°C Benchtop Freezer
2 Páginas
-
Heratherm Heating and Drying Ovens
20 Páginas
-
Thermo Scientific Benchtop Shakers
28 Páginas
-
Nicolet iS10 FT-IR Spectrometer
12 Páginas
-
Nunc Cell Factory Shaker System
8 Páginas
-
mySPIN Mini Centrifuge Series
4 Páginas
-
Anza Restriction Enzyme Cloning System
12 Páginas
-
Ion S5 and Ion S5 XL Systems
2 Páginas
-
SureTect Range
4 Páginas
-
QuantStudio™ 3
8 Páginas
-
Furnaces
2 Páginas
-
Nunc Serological Pipettes
3 Páginas
-
Nunc Cell Factory system equipment
4 Páginas
-
Nunc Cell Factory systems
8 Páginas
-
Vanquish Duo UHPLC System [ZH]
12 Páginas
-
native MS
16 Páginas
-
Compound Discoverer Software
12 Páginas
-
Vanquish Horizon UHPLC System
16 Páginas
-
Sentinel Multiscan Metal Detector
4 Páginas
-
Continuous Flow Isotope Ratio MS
5 Páginas
-
Thermo Scientific TSQ Duo
9 Páginas
-
Thermo Scientific TSQ 8000 Evo
16 Páginas
-
Nunc Cell Factory System Equipment
4 Páginas
-
Heraeus Labofuge 300
2 Páginas
-
Heraeus Labofuge 200 Centrifuge
2 Páginas
-
Heraeus Cryofuge 5500i
8 Páginas
-
Heraeus Clinifuge Centrifuge
2 Páginas
-
Vials and Closures Catalog 2014-2015
128 Páginas
-
Heratherm Large Capacity Ovens
2 Páginas
-
RM 200 EG
4 Páginas
-
Darwin LIMS
2 Páginas
-
Immunohistory Solutions
292 Páginas
-
Remel and Oxoid Product Catalog, Europe
84 Páginas
-
Foodborne Pathogens Testing Guide
32 Páginas
-
Finnpipette Finntip Product Catalog
40 Páginas
-
Process Water Products Catalog
68 Páginas
-
Technical Training Catalog
15 Páginas
-
Smart-Vue Wireless Monitoring Solution
16 Páginas
-
Reagents, Solvents and Accessories
56 Páginas
-
FBS Alternatives
8 Páginas
-
European Prepared Media Selection Guide
66 Páginas
-
iCAP Q Consumables and Parts Catalog
7 Páginas
-
LC Columns and Accessories Catalog 2014-2015
246 Páginas
-
Pierce Magnetic Beads
16 Páginas
-
Thermo Scientific TRACE 1300 Series
12 Páginas
-
interactive catalog today
222 Páginas
-
HERAGUARD HPH clean benches
2 Páginas
-
Forma 1800 Series Clean Bench
2 Páginas
-
MBC 240 Bench Top Analyzer
4 Páginas
-
Konelab 20
2 Páginas
-
Indiko
6 Páginas