Excertos do catálogo

Targeted sequencing has never been simpler Ion Torrent™ technology has been referenced in over 1,500 publications in just the first 4 years since its introduction. Now you can drive your research forward using this highly cited technology with the latest innovation in leadingedge benchtop next-generation sequencing: the Ion S5™ and Ion S5™ XL Systems. Whether it’s the Ion S5 System for small-scale studies and lower weekly throughput or the Ion S5 XL System for faster analysis and higher weekly throughput, you’ve got a simple and scalable sequencer that can match your unique project needs. • Less than 15 minutes of sequencer hands-on time. • ess than 45 minutes of hands-on time for a DNA-to-data L targeted sequencing workflow. • ingle sequencer, multiple applications and multiple S chip formats to match dynamic research needs. Cancer research • Identify fusion transcripts in tissue samples. • xplore SNPs, indels, CNVs and even gene expression E levels from 10ng of FFPE DNA or RNA. Speed • 2.5 to 4 hours for a sequencing run. Inherited disease research • Investigate known variants associated with drug metabolism. • As little as 24 hours to go from DNA to data. • Sequence both small and large gene research panels. • iscover SNPs, indels and CNVs for research of rare D or unknown disorders by whole exome sequencing. Small sample input • 0ng low-quality DNA or RNA needed to generate 1 mutational or gene expression profiles. † Automated analysis time includes aligned BAM files. Infectious disease research • Identify and type microbes through genome sequencing. • Assess known variants associated with antibiotic resistance. Aneuploidy research • High–throug
Abrir o catálogo na página 1
Simple, rapid workflow with less than 45 minutes of hands-on time The combination of Ion AmpliSeq™ technology for target selection, the Ion Chef™ System for automated library and template preparation, and Ion Reporter™ Software for automated variant annotation has made targeted sequencing simpler than ever. Construct library Prepare template Analyze data Hands-on time: 15 minutes Run time: 7 hours Hands-on time: 15 minutes Run time: 11 hours (overnight run) Hands-on/setup time: <15 minutes Run time: 2.5 hours Hands-on time: N/A Run time: 5 hours Ion AmpliSeq™ Cancer Hotspot Panel v2 on the...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos Thermo Scientific
-
CryoStar NX50
2 Páginas
-
Precise sections – perfectly simple
6 Páginas
-
MSC-Advantage BSC
54 Páginas
-
Multifuge
58 Páginas
-
Sorvall WX+ Ultracentrifuge Series
8 Páginas
-
Thermo Scientific Pico 17 / 21
52 Páginas
-
Forma Series II Water Jacket CO2 Incubator
104 Páginas
-
CO2 Incubator HERAcell 150 i / 240 i
196 Páginas
-
Revco® Blood Bank Refrigerators
37 Páginas
-
Multidrop Combi nL
4 Páginas
-
Forma Environmental Chambers
25 Páginas
-
MaxQ 6000
40 Páginas
-
Multi Tube Rotator
13 Páginas
-
picoSpin Spectrometer
6 Páginas
-
1300 Series A2
76 Páginas
-
CO2 Incubator Family
28 Páginas
-
CO2 incubators
7 Páginas
-
Series 8000 Direct-Heat CO2 Incubators
84 Páginas
-
MaxQ Mini 4450 Shaker
40 Páginas
-
E1-ClipTip Electronic Pipette
108 Páginas
-
Varioskan™ LUX
54 Páginas
-
Spinnaker Advanced Benchtop Robot
2 Páginas
-
ISQ Series Mass Spectrometers
412 Páginas
-
Thermo Scientific GasBench II
8 Páginas
-
Q Exactive™ BioPharma
16 Páginas
-
Q Exactive Plus
4 Páginas
-
LTQ XL™
4 Páginas
-
Thermo Scientific Exactive Plus
4 Páginas
-
Platinum DNA polymerases
6 Páginas
-
-80°C Benchtop Freezer
2 Páginas
-
Heratherm Heating and Drying Ovens
20 Páginas
-
Thermo Scientific Benchtop Shakers
28 Páginas
-
Nicolet iS10 FT-IR Spectrometer
12 Páginas
-
Nunc Cell Factory Shaker System
8 Páginas
-
mySPIN Mini Centrifuge Series
4 Páginas
-
Anza Restriction Enzyme Cloning System
12 Páginas
-
Ion S5 and Ion S5 XL Systems
2 Páginas
-
SureTect Range
4 Páginas
-
QuantStudio™ 3
8 Páginas
-
Furnaces
2 Páginas
-
Nunc Serological Pipettes
3 Páginas
-
Nunc Cell Factory system equipment
4 Páginas
-
Nunc Cell Factory systems
8 Páginas
-
Vanquish Duo UHPLC System [ZH]
12 Páginas
-
native MS
16 Páginas
-
Compound Discoverer Software
12 Páginas
-
Vanquish Horizon UHPLC System
16 Páginas
-
Sentinel Multiscan Metal Detector
4 Páginas
-
Continuous Flow Isotope Ratio MS
5 Páginas
-
Thermo Scientific TSQ Duo
9 Páginas
-
Thermo Scientific TSQ 8000 Evo
16 Páginas
-
Nunc Cell Factory System Equipment
4 Páginas
-
Heraeus Labofuge 300
2 Páginas
-
Heraeus Labofuge 200 Centrifuge
2 Páginas
-
Heraeus Cryofuge 5500i
8 Páginas
-
Heraeus Clinifuge Centrifuge
2 Páginas
-
Vials and Closures Catalog 2014-2015
128 Páginas
-
Heratherm Large Capacity Ovens
2 Páginas
-
RM 200 EG
4 Páginas
-
Darwin LIMS
2 Páginas
-
Immunohistory Solutions
292 Páginas
-
Remel and Oxoid Product Catalog, Europe
84 Páginas
-
Foodborne Pathogens Testing Guide
32 Páginas
-
Finnpipette Finntip Product Catalog
40 Páginas
-
Process Water Products Catalog
68 Páginas
-
Technical Training Catalog
15 Páginas
-
Smart-Vue Wireless Monitoring Solution
16 Páginas
-
Reagents, Solvents and Accessories
56 Páginas
-
FBS Alternatives
8 Páginas
-
European Prepared Media Selection Guide
66 Páginas
-
iCAP Q Consumables and Parts Catalog
7 Páginas
-
LC Columns and Accessories Catalog 2014-2015
246 Páginas
-
Pierce Magnetic Beads
16 Páginas
-
Thermo Scientific TRACE 1300 Series
12 Páginas
-
interactive catalog today
222 Páginas
-
HERAGUARD HPH clean benches
2 Páginas
-
Forma 1800 Series Clean Bench
2 Páginas
-
MBC 240 Bench Top Analyzer
4 Páginas
-
Konelab 20
2 Páginas
-
Indiko
6 Páginas