Excertos do catálogo

Thermo Scientific Orion 2001SC Product Specifications Greater stability and reliability, with ± 0.02 pH accuracy over long periods of time. Virtually drift resistant, saving valuable time by reducing calibration frequency while maximizing up-time! High Purity ROSS® pH Electrode High Purity Water pH Measurements with Complete Assurance Markets • Power Generation • Pulp and Paper • Semiconductor • Pharmaceutical • Drinking Water Applications • Boiler Water • Condensate • Bottling Water • Municipal Water • Water for Injection • Water for Fabrication The Thermo Scientific Orion 2001SC high purity ROSS pH electrode is a combination electrode designed for online applications when the highest accuracy and precision are required. The pH sensing and reference electrodes are combined into a single electrode best suited for high purity measurements. The 2001SC electrode is designed to be used in the Thermo Scientific Orion stainless steel flow cell, which holds and positions the electrode for optimal results. The 2001SC high purity ROSS pH electrode is a research-grade electrode engineered specifically for use in online pH measurement applications. It is designed with a sidearm, for attachment to a reservoir of specially formulated ROSS reference filling solution. This ensures the outer reference chamber is always full, allowing the ceramic liquid junction to flow freely. With its unique internal element system, the high purity ROSS pH electrode provides superior stability, faster response and greater accuracy than other conventional electrodes with silver chloride or calomel internal systems. The electrode response is fast; even in samples varying by 50 °C or more. Drift is less than 0.002 pH units per day, eliminating the need for frequent standardization. The ROSS internal system is designed to have virtually zero temperature coefficient, that is, the potential difference between the elements is zero regardless of the difference in the temperature of the elements. The internal elements of the combination pH electrodes are housed in an electrode body that, in use, is partially immersed in the sample and partially exposed to the ambient air. Thus, the internal elements may be at different temperatures.
Abrir o catálogo na página 1
Specifications and Product Information 2001SC High Purity ROSS Electrode Benefits • Unmatched drift-free reference system — with precision of 0.02 pH • Reliable, reproducible results in high purity samples Less than 0.002 pH units • Fastest response for online pH electrodes Isopotential Point Ceramic frit • Unparalleled pH response to temperature changes Internal Reference Electrode Diameter: 12 mm Electrode Length: 125 mm Electrode Cap Diameter: 16 mm Electrode Cap Length: 30 mm Detachable Cable Cable Length Filling Solution ROSS reference filling solution • Eliminates junction potential...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos Thermo Scientific
-
CryoStar NX50
2 Páginas
-
Precise sections – perfectly simple
6 Páginas
-
MSC-Advantage BSC
54 Páginas
-
Multifuge
58 Páginas
-
Sorvall WX+ Ultracentrifuge Series
8 Páginas
-
Thermo Scientific Pico 17 / 21
52 Páginas
-
Forma Series II Water Jacket CO2 Incubator
104 Páginas
-
CO2 Incubator HERAcell 150 i / 240 i
196 Páginas
-
Revco® Blood Bank Refrigerators
37 Páginas
-
Multidrop Combi nL
4 Páginas
-
Forma Environmental Chambers
25 Páginas
-
MaxQ 6000
40 Páginas
-
Multi Tube Rotator
13 Páginas
-
picoSpin Spectrometer
6 Páginas
-
1300 Series A2
76 Páginas
-
CO2 Incubator Family
28 Páginas
-
CO2 incubators
7 Páginas
-
Series 8000 Direct-Heat CO2 Incubators
84 Páginas
-
MaxQ Mini 4450 Shaker
40 Páginas
-
E1-ClipTip Electronic Pipette
108 Páginas
-
Varioskan™ LUX
54 Páginas
-
Spinnaker Advanced Benchtop Robot
2 Páginas
-
ISQ Series Mass Spectrometers
412 Páginas
-
Thermo Scientific GasBench II
8 Páginas
-
Q Exactive™ BioPharma
16 Páginas
-
Q Exactive Plus
4 Páginas
-
LTQ XL™
4 Páginas
-
Thermo Scientific Exactive Plus
4 Páginas
-
Platinum DNA polymerases
6 Páginas
-
-80°C Benchtop Freezer
2 Páginas
-
Heratherm Heating and Drying Ovens
20 Páginas
-
Thermo Scientific Benchtop Shakers
28 Páginas
-
Nicolet iS10 FT-IR Spectrometer
12 Páginas
-
Nunc Cell Factory Shaker System
8 Páginas
-
mySPIN Mini Centrifuge Series
4 Páginas
-
Anza Restriction Enzyme Cloning System
12 Páginas
-
Ion S5 and Ion S5 XL Systems
2 Páginas
-
SureTect Range
4 Páginas
-
QuantStudio™ 3
8 Páginas
-
Furnaces
2 Páginas
-
Nunc Serological Pipettes
3 Páginas
-
Nunc Cell Factory system equipment
4 Páginas
-
Nunc Cell Factory systems
8 Páginas
-
Vanquish Duo UHPLC System [ZH]
12 Páginas
-
native MS
16 Páginas
-
Compound Discoverer Software
12 Páginas
-
Vanquish Horizon UHPLC System
16 Páginas
-
Sentinel Multiscan Metal Detector
4 Páginas
-
Continuous Flow Isotope Ratio MS
5 Páginas
-
Thermo Scientific TSQ Duo
9 Páginas
-
Thermo Scientific TSQ 8000 Evo
16 Páginas
-
Nunc Cell Factory System Equipment
4 Páginas
-
Heraeus Labofuge 300
2 Páginas
-
Heraeus Labofuge 200 Centrifuge
2 Páginas
-
Heraeus Cryofuge 5500i
8 Páginas
-
Heraeus Clinifuge Centrifuge
2 Páginas
-
Vials and Closures Catalog 2014-2015
128 Páginas
-
Heratherm Large Capacity Ovens
2 Páginas
-
RM 200 EG
4 Páginas
-
Darwin LIMS
2 Páginas
-
Immunohistory Solutions
292 Páginas
-
Remel and Oxoid Product Catalog, Europe
84 Páginas
-
Foodborne Pathogens Testing Guide
32 Páginas
-
Finnpipette Finntip Product Catalog
40 Páginas
-
Process Water Products Catalog
68 Páginas
-
Technical Training Catalog
15 Páginas
-
Smart-Vue Wireless Monitoring Solution
16 Páginas
-
Reagents, Solvents and Accessories
56 Páginas
-
FBS Alternatives
8 Páginas
-
European Prepared Media Selection Guide
66 Páginas
-
iCAP Q Consumables and Parts Catalog
7 Páginas
-
LC Columns and Accessories Catalog 2014-2015
246 Páginas
-
Pierce Magnetic Beads
16 Páginas
-
Thermo Scientific TRACE 1300 Series
12 Páginas
-
interactive catalog today
222 Páginas
-
HERAGUARD HPH clean benches
2 Páginas
-
Forma 1800 Series Clean Bench
2 Páginas
-
MBC 240 Bench Top Analyzer
4 Páginas
-
Konelab 20
2 Páginas
-
Indiko
6 Páginas