Frequently Asked Questions General Questions Is the Thermo Scientific™ picoSpin™ 45 NMR spectrometer really the world’s first compact NMR spectrometer? Haven’t desktop NMR machines been around for years? In a proton NMR spectrum, lines are typically separated by a few parts per million (ppm). To qualify as a true spectrometer, an NMR system must have resolution well below 1 ppm. The picoSpin 45’s resolution is better than 0.06 ppm, or 60 ppb (parts per billion). Before the picoSpin 45, all commercial compact NMR machines had resolution that was too poor for them to qualify as spectrometers....

Abrir o catálogo na página 3
picoSpin Spectrometer - 4

Frequently Asked Questions Sample Handling Why does the picoSpin have a capillary cartridge? For convenient replacement. When reasonable precautions are observed, problems with clogging and contamination of the capillary can be avoided. However, accidents do occur, and when they do, it is a great advantage to be able to replace the capillary in the field. Cartridge changes only take a few minutes. The unit should be reshimmed whenever the cartridge is changed. What experiments can I do other than 1-D spectroscopy? The picoSpin contains a general-purpose programmable pulse sequencer with 20...

Abrir o catálogo na página 4
picoSpin Spectrometer - 5

Frequently Asked Questions Chemical Applications Chemical Applications What kind of samples can I measure? Any proton-containing liquid, not too viscous for injection into a 0.4 mm ID capillary, can be used. Will the signal I am looking for be strong enough to see? Good question! It is always a good idea to estimate the signal-to-noise ratio (SNR) before you get started with unfamiliar samples. The exact SNR depends on many things, including the magnet shim and the way data is recorded and analyzed. However, you can usually make an adequate estimate like this: The picoSpin single-scan SNR...

Abrir o catálogo na página 5
picoSpin Spectrometer - 6

Frequently Asked Questions Installation Installation Where can I install a picoSpin spectrometer? There are no special facilities or environmental requirements. You can place a picoSpin spectrometer in any indoor location where a person would be comfortable; however, temperature changes must be gradual during the course of a data acquisition. AC magnetic fields generated by nearby utility power that are stronger than 1 mGauss amplitude will cause small side-bands to appear on spectra. In unusual cases where this is a problem, the unit can be oriented so that the AC field vector is...

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos Thermo Scientific

  1. CryoStar NX50

    2 Páginas

  2. MSC-Advantage BSC

    54 Páginas

  3. Multifuge

    58 Páginas

  4. MaxQ 6000

    40 Páginas

  5. Multi Tube Rotator

    13 Páginas

  6. 1300 Series A2

    76 Páginas

  7. CO2 incubators

    7 Páginas

  8. Varioskan™ LUX

    54 Páginas

  9. Q Exactive Plus

    4 Páginas

  10. LTQ XL™

    4 Páginas

  11. SureTect Range

    4 Páginas

  12. QuantStudio™ 3

    8 Páginas

  13. Furnaces

    2 Páginas

  14. native MS

    16 Páginas

  15. RM 200 EG

    4 Páginas

  16. Darwin LIMS

    2 Páginas

  17. FBS Alternatives

    8 Páginas

  18. Konelab 20

    2 Páginas

  19. Indiko

    6 Páginas