Excertos do catálogo
Thermo Scientific Hamilton Laboratory Fume Hood Capabilities Part ofThermo Fisher Scientific
Abrir o catálogo na página 1A Legacy of Quality and Performance Over the past 125 years, we have built a reputation by creating the finest laboratory products in the world. Today, through the support of an experienced full-service team and the most comprehensive fume hood test program in the industry, our commitment to the scientific community is unequaled. The combined support of our dealers and company representatives keeps us attuned to requirements in customer personnel, procedures and technology. Market Leader in Innovative Product Design The legacy of leading the industry with user driven design solutions to...
Abrir o catálogo na página 2Fume Hood Testing / Technical Support Thermo Scientific Hamilton fume hoods are subjected to ASHRAE 110 testing with a report attached to each fume hood shipped, providing performance validation. Our commitment to testing was instituted with the onset of ASHRAE 110 procedures and continues to be unmatched. Technical support is offered by both distributors of Thermo Scientific Hamilton Fume Hoods and employees specializing in fume hood technology, performance and safety. Conserving Air and Energy Our products address the changing needs of today’s end-users, while contributing to a safer,...
Abrir o catálogo na página 335" High Sightline Provides users with optimum visibility of fume hood interior. Thermo Scientific Hamilton Pioneer Designed to maximize containment performance and energy efficiency, the Thermo Scientific Hamilton Directed Airflow Technology makes this possible. Subjected to both standard and modified ASHRAE test procedures, the Pioneer® has been tested at face velocities as low as 50 fpm, sash fully open, with unmatched performance. Fixed Baffle System Dual Performance Monitor The baffle system is factory-tuned for optimal airflow characteristics and requires no adjustment. A...
Abrir o catálogo na página 4Thermo Scientific Hamilton Concept This fume hood is ideal for your low flow applications and provides excellent performance at lower (60 fpm) face velocities. Timeless, attractive styling complements all laboratories while providing you with safety and energy cost savings. Downdraft Bypass Air flows through the bypass area with increased volume and less resistance for quieter operation. Secondary Trough Additional safeguard for the containment of spills not secured by a dished work surface 35" High Sightline Optimum visibility of the hood interior. AutoSash Automatic Positioning System The...
Abrir o catálogo na página 5Thermo Scientific Hamilton SafeAireII Designed and tested to ensure dependable performance, the Hamilton SafeAire® II works in concert with overall HVAC systems. Considered the most versatile of our fume hoods, the Hamilton SafeAire II offers broad usage in all types of laboratories. Increased Vertical Space The exhaust collar and baffle angle designs create additional space and are perfect for taller apparatus. Metal-Free Interior Five non-metallic liners are resistant to high temperatures and meet all NFPA 45 standards. Interiors do not have metal brackets, angles or screw heads (which...
Abrir o catálogo na página 6Thermo Scientific Hamilton ProVent Unique Exhaust Collar Design Airfoil Provides more vertical space, reduces noise levels and conserves energy by maintaining lower static pressure. Improves the flow characteristics near the work surface Exterior Fluorescent Lighting Excellent task lighting and is located safely away from harmful fumes and vapors. Liner Materials Low flame spread ratings meets NFPA standards. Blank Cutout Optional blower switch or safety monitor location. Sash Safety Features The unframed sash design has greater impact resistance. The 18" sash lock/release defines the...
Abrir o catálogo na página 7Fume Hood Test Facility Quality Control Fume Hood Testing and Certification Testing and certification to ASHRAE 110 is standard procedure for every type and size of fume hood we manufacture. Quantitative/qualitative assessments and quality control are tested. • Electronic face velocity probes monitor a grid generating multiple readings per second. • Fume hood containment testing utilizes a mannequin with a leak meter mounted to the breathing zone to simulate a person standing in front of a fume hood. A tracer gas is injected into the fume hood, and the meter measures escaping gas. Testing...
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos Thermo Scientific
-
CryoStar NX50
2 Páginas
-
Precise sections – perfectly simple
6 Páginas
-
MSC-Advantage BSC
54 Páginas
-
Multifuge
58 Páginas
-
Sorvall WX+ Ultracentrifuge Series
8 Páginas
-
Thermo Scientific Pico 17 / 21
52 Páginas
-
Forma Series II Water Jacket CO2 Incubator
104 Páginas
-
CO2 Incubator HERAcell 150 i / 240 i
196 Páginas
-
Revco® Blood Bank Refrigerators
37 Páginas
-
Multidrop Combi nL
4 Páginas
-
Forma Environmental Chambers
25 Páginas
-
MaxQ 6000
40 Páginas
-
Multi Tube Rotator
13 Páginas
-
picoSpin Spectrometer
6 Páginas
-
1300 Series A2
76 Páginas
-
CO2 Incubator Family
28 Páginas
-
CO2 incubators
7 Páginas
-
Series 8000 Direct-Heat CO2 Incubators
84 Páginas
-
MaxQ Mini 4450 Shaker
40 Páginas
-
E1-ClipTip Electronic Pipette
108 Páginas
-
Varioskan™ LUX
54 Páginas
-
Spinnaker Advanced Benchtop Robot
2 Páginas
-
ISQ Series Mass Spectrometers
412 Páginas
-
Thermo Scientific GasBench II
8 Páginas
-
Q Exactive™ BioPharma
16 Páginas
-
Q Exactive Plus
4 Páginas
-
LTQ XL™
4 Páginas
-
Thermo Scientific Exactive Plus
4 Páginas
-
Platinum DNA polymerases
6 Páginas
-
-80°C Benchtop Freezer
2 Páginas
-
Heratherm Heating and Drying Ovens
20 Páginas
-
Thermo Scientific Benchtop Shakers
28 Páginas
-
Nicolet iS10 FT-IR Spectrometer
12 Páginas
-
Nunc Cell Factory Shaker System
8 Páginas
-
mySPIN Mini Centrifuge Series
4 Páginas
-
Anza Restriction Enzyme Cloning System
12 Páginas
-
Ion S5 and Ion S5 XL Systems
2 Páginas
-
SureTect Range
4 Páginas
-
QuantStudio™ 3
8 Páginas
-
Furnaces
2 Páginas
-
Nunc Serological Pipettes
3 Páginas
-
Nunc Cell Factory system equipment
4 Páginas
-
Nunc Cell Factory systems
8 Páginas
-
Vanquish Duo UHPLC System [ZH]
12 Páginas
-
native MS
16 Páginas
-
Compound Discoverer Software
12 Páginas
-
Vanquish Horizon UHPLC System
16 Páginas
-
Sentinel Multiscan Metal Detector
4 Páginas
-
Continuous Flow Isotope Ratio MS
5 Páginas
-
Thermo Scientific TSQ Duo
9 Páginas
-
Thermo Scientific TSQ 8000 Evo
16 Páginas
-
Nunc Cell Factory System Equipment
4 Páginas
-
Heraeus Labofuge 300
2 Páginas
-
Heraeus Labofuge 200 Centrifuge
2 Páginas
-
Heraeus Cryofuge 5500i
8 Páginas
-
Heraeus Clinifuge Centrifuge
2 Páginas
-
Vials and Closures Catalog 2014-2015
128 Páginas
-
Heratherm Large Capacity Ovens
2 Páginas
-
RM 200 EG
4 Páginas
-
Darwin LIMS
2 Páginas
-
Immunohistory Solutions
292 Páginas
-
Remel and Oxoid Product Catalog, Europe
84 Páginas
-
Foodborne Pathogens Testing Guide
32 Páginas
-
Finnpipette Finntip Product Catalog
40 Páginas
-
Process Water Products Catalog
68 Páginas
-
Technical Training Catalog
15 Páginas
-
Smart-Vue Wireless Monitoring Solution
16 Páginas
-
Reagents, Solvents and Accessories
56 Páginas
-
FBS Alternatives
8 Páginas
-
European Prepared Media Selection Guide
66 Páginas
-
iCAP Q Consumables and Parts Catalog
7 Páginas
-
LC Columns and Accessories Catalog 2014-2015
246 Páginas
-
Pierce Magnetic Beads
16 Páginas
-
Thermo Scientific TRACE 1300 Series
12 Páginas
-
interactive catalog today
222 Páginas
-
HERAGUARD HPH clean benches
2 Páginas
-
Forma 1800 Series Clean Bench
2 Páginas
-
MBC 240 Bench Top Analyzer
4 Páginas
-
Konelab 20
2 Páginas
-
Indiko
6 Páginas